Add description, images, menus and links to your mega menu
A column with no settings can be used as a spacer
Link to your collections, sales and even external links
Add up to five columns
Add description, images, menus and links to your mega menu
A column with no settings can be used as a spacer
Link to your collections, sales and even external links
Add up to five columns
September 08, 2026 4 min read
Quick installation guide for the Zipato Smart Energy Plug In Switch (PH-PAN15), a Z-Wave Plus plug-in on/off switch with energy metering and overload protection.
Quick installation guide for the Zipato Smart Energy Plug In Switch (regulatory model PH-PAN15), a Z-Wave Plus plug-in on/off switch with energy metering and overload protection.
This is a security-enabled Z-Wave Plus plug-in switch. Devices displaying the Z-Wave Plus logo can be used with it regardless of manufacturer, and it can join other manufacturers' Z-Wave networks. It supports Security Command Class and functions identically whether included as a secure or non-secure device. The switch detects instantaneous wattage and overload current on connected loads — when overload is detected, the switch disables and locks out the On/Off button (LED flashes quickly) until it's unplugged and reconnected.
| Spec | Value |
|---|---|
| Protocol | Z-Wave Plus |
| Operating Voltage | 100-240VAC/60Hz; 220-240VAC/50Hz |
| Maximum Load | 13A (Resistive load) |
| Operating Temperature | 0 ~ 40°C |
| Humidity | 85% RH max |
| Range | Minimum 40m indoor / 100m outdoor |
| Measurement Error | 3W / 5% (under 40W) |
| Weight / Dimensions | 66g; 45mm x 35mm x 65mm |
| Frequency (EU) | 868.40 MHz, 869.85 MHz |
| State | LED Indication |
|---|---|
| Normal | LED on when ON, off when OFF |
| No Node ID | Flashes on/off every 2 seconds (not yet allocated a node ID) |
| Learning | Flashes on/off every 0.5 seconds |
| Overload | Flashes on/off every 0.2 seconds; clear by unplugging and reconnecting |
| Function | Procedure |
|---|---|
| Inclusion | Put your Z-Wave controller into inclusion mode, then press the On/Off button 3 times within 2 seconds. |
| Exclusion | Put your Z-Wave controller into exclusion mode, then press the On/Off button 3 times within 2 seconds. |
| Reset (use only if primary controller lost/inoperable) | Within 1 second, press On/Off button again and hold for 5 seconds. |
Auto Inclusion: When power is first applied, the switch's LED flashes on/off every 0.5s, indicating it has no node ID and has begun auto inclusion (a 2-minute timeout window). Auto inclusion doesn't require pressing the On/Off button.
The switch supports one association group (Grouping 1, max 1 node), reporting SWITCH_BINARY_REPORT, METER_REPORT, and ALARM_REPORT to the associated Z-Wave controller.
Supports Protection Command Class v2 to prevent unintentional control (e.g., by a child) and to lock out RF control entirely if desired. In "Protection by sequence" mode, the On/Off button must be held longer than 1 second to change state.
| Symptom | Cause | Recommendation |
|---|---|---|
| Switch not working, LED off | Not plugged in properly, or switch failure | Check power connections; do not open the module — send for repair if broken. |
| LED on but can't control the load's own switch | Load has its own On/Off switch, or switch is protected | Set the load's own switch to ON; unprotect the switch. |
| LED illuminating but detector can't control the switch | Association not carried out, or RF interference | Carry out association; wait and retry if there's frequency interference. |
| LED keeps flashing, can't control switch | Overload occurred | Remove the attached load or ensure max load doesn't exceed 12A. |
www.zipato.com, community.zipato.com, support@zipato.com.
One (1) year limited hardware warranty from Tri plus grupa d.o.o. (Zipato). Contact: Banjavciceva 11, 10000 Zagreb, Croatia. Tel +385 (0)1 4004 404.