User manual for the Yale Pro 2 Key-Free YRD634/YRD654 Z-Wave Plus 500 Series smart deadbolt, covering installation, programming and troubleshooting.
User manual for the Yale Pro 2 Key-Free YRD634 / YRD654 Z-Wave Plus 500 Series smart deadbolt — covers installation, programming, and troubleshooting for this keypad-only (no physical key) electronic deadbolt.
The Yale Pro 2 Key-Free lock is a keyless keypad deadbolt with Z-Wave Plus connectivity via a removable Yale Smart Module, entry-code management, auto-lock, and passage mode. Important: key-free locks should only be installed on homes with more than one point of entry.
Use the tear-out Door Checker template to confirm your door and frame match the lock's requirements before making any adjustments:
If your door doesn't match any of these dimensions, it is not compatible with this lock as-is.
Required tools: Phillips head screwdriver, tape measure, drill, pencil, wood mortise chisel, utility knife, level (plus the tear-out Door Checker and Marking Template pages).
Caution: Failure to follow the installation guide precisely could damage the product, void the factory warranty, and could cause the lock to fail to provide access.
| Menu | Option | Action |
|---|---|---|
| 1 — Programming Code | Change the programming code | Enter a new 4–8 digit code |
| 2 — User Codes | 1 = Create; 3 = Remove | Enter a 4–8 digit user code (enter 00 to remove all codes) |
| 3 — Advanced Settings | 1 = Auto Relock; 2 = Inside LED; 3 = One Touch Locking; 5 = Handing the lock | Auto Relock: 1–180 seconds or off; LED/Locking: on/off |
| 4 — Sound Settings | Turn on / off | — |
| 6 — All Code Lock Out | Turn on / off | — |
| 7 — Z-Wave | Enroll / Unenroll | — |
| 8 — Bluetooth Advertising | Turn on | — |
| Symptom | Fix |
|---|---|
| Lock does not respond | Press Yale logo to activate keypad; check batteries are correctly installed/oriented; check keypad wire is fully connected and not pinched. |
| Lock is on briefly then no reaction / lights dim | Batteries low on power — replace. |
| Chimes acceptance but door won't open | Check for foreign objects between door and frame; check wire connection to interior lock. |
| Allows access but won't auto-unlock | Check if Auto-Lock is enabled; disable to lock manually instead. |
| "Low Battery" response | Replace all 4 AA batteries. |
| Batteries completely drained | Replace all 4 AA batteries. To operate temporarily, hold a 9V alkaline battery against the contacts at the bottom of the lock, wait a moment, press the logo to wake it, then enter your code while holding the battery in place. |
| Entry code won't register | Check low battery indicator; verify code is 4–8 digits and unique per user; enter the code within 5 seconds of waking the keypad. |
| "Invalid Code" or times out | Verify the code is valid and previously programmed; turn off vacation mode via the programming menu (requires programming code). |
| "Wrong Number of Digits" | Re-enter the correct code followed by the Check key. |
| Deadbolt doesn't extend with keypad | Lock was not handed properly — adjust the "Lock Handing" setting. |
| Lock operates but makes no sound | Turn on volume via the programming menu (requires programming code). |
| Symptom | Fix |
|---|---|
| Deadbolt grinds/won't extend via keypad, but thumbturn works smoothly | Lock not handed properly — adjust "Lock Handing" setting. |
| Deadbolt hits the strike plate | Reposition strike plate to align with the deadbolt. |
| Deadbolt not fully extending | Increase the depth of the deadbolt strike pocket in the frame. |
| Resistance/binding requiring pushing or pulling to align deadbolt/latch | Adjust the knob/lever/handleset strike plate: remove it with a hand screwdriver, bend the tab toward the strike surface slightly, reinstall and retest. If insufficient, contact a locksmith for latch/deadbolt adjustment. |
For door alignment help, see the video at US.YaleHome.com/Support.
FCC ID: 2ABFG-YRD450BLEV1; IC ID: 11626A-YRD450BLEV1. Class B digital device per FCC Part 15 — tested to provide reasonable protection against interference in residential installations. Changes or modifications not expressly approved by Yale Home could void the user's authority to operate the equipment.
Yale Home 24/7 Support: 1-855-213-5841, or Support.ShopYaleHome.com. Yale® and Yale Pro® 2 are registered trademarks of Masterlock LLC and its affiliates. © 2023 Yale Home. All rights reserved.