Installation and programming instructions for the Yale nexTouch NTT6xx Series Keypad Access Exit Trim Lock (touchscreen and push-button models).
Installation and programming instructions for the Yale nexTouch™ NTT6xx Series Keypad Access Exit Trim Lock — a commercial exit device trim with touchscreen or push-button keypad, sold by Yale (part of ASSA ABLOY). Available in touchscreen (TS) and push-button (PB) versions.
WARNING: This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. See www.P65warnings.ca.gov for more information.
Retrofitting or modifying this product may impact fire rating, safety features, and warranty. Consult code specifications to ensure compliance with all applicable codes and ratings before installation.
Note: If a Yale Accentra Key module is installed, physical/mobile credentials are used instead — User PIN code creation and use are disabled, and the Master PIN code is used only for programming (it will not unlock the door).
Activate the lock, enter the PIN code, press the check key.
When the door is already in a locked state (door closed), press the Privacy button once to activate Privacy Mode. If the door is not locked, press twice — the first press locks the door, the second activates Privacy Mode.
| Menu # | Function | Options (default in bold) |
|---|---|---|
| 1 | Master PIN Code Setting | — |
| 2 | Register User or Passage Codes / Delete a Code | — |
| 3 | Advanced Lock Settings: Automatic Re-lock | 1-180 sec / Disable |
| 3 | Inside Indicator Light | Enable / Disable |
| 3 | One Touch Locking | Enable / Disable |
| 3 | Privacy (requires DPS) | Enable / Disable |
| 3 | Eco Mode | Enable / Disable |
| 4 | Volume Setting | High / Low / Silent |
| 5 | Language Setting | English / Spanish / French |
| 6 | All Code Lockout | Enable / Disable |
Warning: A factory reset deletes all user codes including the Master PIN and resets all programming to defaults. Master PIN creation is the only available option afterward and must be completed before any further programming.
| Symptom | Suggested Action |
|---|---|
| Lock does not respond, no lights/chimes/latch movement | Check battery polarity/installation, replace batteries, check cable connections inside lock, or apply 9V battery to the terminals for emergency power |
| Lock wakes but doesn't respond, lights dim | Batteries low on power — replace |
| Chimes acceptance but door won't open | Check for another locking device (deadbolt), check door gaps for obstructions, confirm motor cable is seated on the "MOTOR" PC board connector |
| Lock unlocks but won't auto re-lock | Confirm Auto Re-lock is enabled, replace batteries, confirm Passage Mode is disabled |
| User/Passage PIN won't register | Check code length (4-8 digits), check if already registered, check for installed Accentra module (disables User PINs), enter within 20 seconds, avoid check/gear keys within the PIN |
| Lock errors/times out entering a PIN | Re-enter digits correctly, check if Master deleted the code, check code expiration, check for Accentra module, retry within 20 seconds |
| "Low Battery" displayed / Yale logo flashes red | Replace all 4 AA alkaline batteries |
| Lock operates but doesn't chime | Confirm Volume is set to Low or High (not Silent) |
| Won't enter Privacy Mode | Confirm Privacy Mode is enabled by Master user; check door gap alignment |
Hardware troubleshooting — door binding: confirm the door and frame are properly aligned and the door swings freely; check that hinges aren't loose or worn. Refer to the exit device installation instructions for additional hardware troubleshooting.
| Setting | Factory Default |
|---|---|
| Master PIN Code | Creation required |
| All Code Lockout Mode | Disabled |
| Automatic Re-lock | 3 seconds |
| Eco Mode | Disabled |
| Inside Indicator Light | Enabled |
| Language | English (retained through factory reset) |
| One Touch Locking | Enabled |
| Privacy | Disabled |
| Shutdown Time | 60 seconds |
| Volume Setting | High |
| Wrong Code Entry Limit | 5 attempts |