September 08, 2026 8 min read
Complete installation and programming instructions for the Yale Assure Lock Electronic Interconnected Push Button (YRC216) — door prep through PIN code setup and optional Z-Wave/ZigBee/iM1 network modules.
Complete installation and programming instructions for the Yale Assure Lock Electronic Interconnected Push Button (YRC216) — covering door prep, mechanical installation, PIN code programming, and optional Z-Wave Plus / ZigBee / iM1 network module setup.
The Yale Assure Lock YRC216 is an interconnected push-button electronic deadbolt/lever lock available in 4" or 5.5" touchscreen keypad sizes. It supports an optional Network Module (Z-Wave Plus, ZigBee, or iM1) for smart home integration. Retrofitting or modifying this product may impact fire rating, safety features, and warranty — always consult local code specifications to ensure compliance.
Full step-by-step installation instructions are also available via the free BILT app, which walks through the process visually. The printed instructions cover the following steps:
After installing batteries and cover, or after a factory reset, you must first create a Master PIN code (see Programming Instructions below). Then:
| Symptom | Suggested Action |
|---|---|
| Bolt will not extend, motor is grinding | Enter Master PIN, select Advanced Lock Settings (Option 3), rehand the lock (Option 5), then test by locking via keypad. |
| Door is binding | Check door/frame alignment and that the door swings freely; check hinges for looseness or wear. |
| Bolt will not deadlock | Check clearance of the bolt within the strike-side jamb (deepen the pocket if needed); check bolt/strike alignment by extending and retracting the bolt with the door open. |
| Bolt does not extend/retract smoothly | Recheck bolt/strike alignment, backset adjustments, door preparation (re-bore misaligned holes), keypad wire harness routing, and correct bolt orientation. |
| Keypad numerics are scrolling | Remove the interior lock and verify the wire harness is routed properly. |
Maximum User Codes: 250 with a Z-Wave Plus or ZigBee network module; 25 without a network module or with an iM1 module; 12 with Bluetooth.
Required upon installation or after a factory reset — the lock cannot be programmed or used until this step is completed. Press the menu key, then the settings key, enter a 4–8 digit Master PIN code, and confirm.
The Master PIN code must be created first. Enter the Master PIN code, press the menu/enter keys, then enter a 4–8 digit User PIN code and confirm.
Enter the PIN code and press "Unlock."
Warning: resetting deletes all user codes, including the Master PIN, and restores all programming features to factory defaults.
For best results, the lock should remain installed on the door during a factory reset. Master PIN code creation is the only option available immediately after reset, and must be completed before any other programming.
| Setting | Factory Default |
|---|---|
| Master PIN Code | Registration required |
| Audio Mode | Disabled |
| Automatic Re-lock | Disabled |
| Inside Indicator Light | Disabled (Off) |
| One Touch Locking | Enabled |
| Privacy Button Setting | Disabled |
| Lockout Mode | Disabled |
| Wrong Code Entry Limit | 5 times |
| Shutdown Time | 60 seconds |
Enter the 4–8 digit Master PIN code followed by the menu key, then enter the digit corresponding to the desired function followed by the menu key again:
| Symptom | Suggested Action |
|---|---|
| Lock doesn't respond, door open/accessible | Press each keypad button to check response; check batteries are installed correctly (polarity) and in good condition; check the cable is fully connected and not pinched. |
| Lock doesn't respond, door locked/inaccessible | Batteries may be fully discharged. Use the key to gain entry and replace batteries. |
| Chimes for code acceptance, but door won't open | Check for another locking device on the door; check for foreign objects in the door gap; check cable connection to the PC board. |
| Unlocks but won't auto re-lock | Check if Auto Re-lock Mode is enabled; replace batteries if the low battery indicator is lit. |
| PIN codes won't register | Codes must be 4–8 digits and unique per user. PIN registration is managed by the Master code — contact the Master user. |
| Beeps/flashes 7 times and won't unlock after PIN + (*) | All Code Lockout Mode is enabled; only the Master can disable it. |
| No sound during operation | Enable Audio Mode. |
| Intermittent RED flashes | Low battery indicator — replace all four AA alkaline batteries. |
Tip: When batteries are replaced on a network-connected lock, verify the real-time clock date/time (especially around Daylight Saving Time changes).
Remove batteries before removing/inserting the Network Module, then reinstall batteries and cover. This is a security-enabled Z-Wave Plus product using encrypted messages, and must be used with a Security Enabled Z-Wave Controller to access all features. It is interoperable with other Z-Wave certified devices; non-battery nodes act as repeaters regardless of vendor.
Specific Z-Wave Plus association and parameter details are available at YaleHome.com/ZwavePlus. Module: YRMZW2-US, FCC ID U4A-YRHCPZW0FM.
Same battery-removal precaution applies. This is a security-enabled ZigBee product requiring a Security Enabled ZigBee Controller for full functionality, and is interoperable with other ZigBee-certified devices.
Module: YRMZB2, FCC ID U4A-YRHCPZB0FM. This device should be operated with a minimum distance of 20cm between the radiator and your body.