September 08, 2026 3 min read
Complete user guide for the Simply Automated UPB Appliance Module, model UMA-E-W — installation, configuration, manual override, and factory default settings.
Complete user guide for the Simply Automated UPB Appliance Module, model UMA-E-W — a plug-in module that turns 120VAC appliances and fluorescent lamps ON/OFF based on digital commands sent over existing home power wiring from a remote UPB (Universal Powerline Bus) controller.
The UMA-E-W receives digital commands over the power wiring — no additional wiring is required and no radio frequency signals are used for communication. UPB controllers and modules can be freely located anywhere in the home.
| Power | 120 VAC ±10%, 60 Hz |
| Max load | 12A or 1/3 HP motor |
| Output type | Relay, 12A |
| Operating temperature | 30 to 120°F (0 to 50°C) |
Designed for indoor use with devices that plug into a power outlet.
CAUTION: Do not insert metal objects into the module, especially the program switch, while it is connected to power.
The module operates according to commands sent by the UPB controller. The indicator glows RED when the controlled outlet is OFF and GREEN when it is ON.
Manual override: Press and hold the Program Switch for at least 3 seconds to enable manual override — the indicator blinks RED-GREEN continuously. While in override, press the Program Switch to turn the appliance ON/OFF locally. Press and hold the Program Switch again for at least 3 seconds to exit manual override.
To restore defaults: place the UMA-E-W in SETUP mode, press the Program Switch ten times, then press it twice again to exit.
| Network Name | "New Network Name" |
| Room Name | "New Room Name" |
| Device Name | "New UMA-E-W" |
| Unit ID | 2 |
| Network ID | 255 |
| Network Password | 1234 |