August 31, 2026 4 min read
Installation manual for the SECO-LARM ENFORCER SK-910RA series miniature RF receivers, covering wiring, code learning, output mode programming, and specifications.
Installation manual for the SECO-LARM ENFORCER SK-910RA series miniature RF receivers (SK-910RA, SK-910RAV, SK-910RAV2), covering wiring, code learning, output mode programming, and specifications for 1- and 2-channel wireless receivers used with garage/gate openers, alarms, and access control.
These mini RF receivers are compatible with both code-hopping (CODEBUMP™) and fixed-code transmitters. They support a variety of applications such as allowing the same transmitter to arm/disarm a vehicle alarm and open/close a garage door opener. Each channel learns codes from up to 15 different transmitter buttons on a first-in, first-out basis.
All models operate on 11-24VAC/DC except the low-voltage versions (3-13.8VDC for the SK-910RAV/RAV2 series).
| Spec | SK-910RA | SK-910RAV | SK-910RAV2 |
|---|---|---|---|
| Range | Up to 500' range | ||
| Operating Voltage | 11-24 V AC/DC (16~24 VAC/DC must cut LP4) | 3-13.8 VDC | |
| Memory Capacity | 15 transmitter button codes per channel | ||
| Current Draw | 5mA standby, 50mA LED flashing @ 12VDC | 5mA standby, 15mA LED flashing @ 12VDC | |
| Output Mode | Programmable 4-sec. momentary (default), 1-sec. momentary, toggle (ON/OFF), or validity | ||
| Output Type | 3A Form "C" relay (NO/NC/C) | Transistor GND x 1, 5A @ 12VDC | Transistor GND x 2, 3A @ 12VDC |
| Dimensions | 3-1/16" x 2-9/16" x 3/4" (80 x 65 x 19 mm) | ||
| Frequency | 315MHz (other frequencies available on request) | ||
| Transmitter Compatibility | Compatible with all SECO-LARM transmitters. Fixed-code: 68 billion codes. CODEBUMP™ code-hopping: 18 quintillion (1.8 x 10^19) codes. | ||
Note: The green LED flashes for a maximum of 15 seconds. If no transmitter button is pressed in that time, the receiver exits code-learning mode.
Same procedure as channel 1, except mode switch #2 (black switch) initiates code-learning, and the red LED shows status. Red push-button = mode switch #1; black push-button = mode switch #2.
| Mode | Behavior |
|---|---|
| 4-second momentary (default) | Press the transmitter button once. Output turns on for 4 seconds, then off. |
| 1-second momentary | Press the transmitter button once. Output turns on for 1 second, then off. |
| Toggle | Press the transmitter button once and the output turns on. Press a compatible transmitter button again and it turns off. |
| Validity | The relay stays on for as long as the transmitter button is pressed. |
Output modes are set by cutting jumpers LP1, LP2, LP3, LP4 inside the receiver case per the jumper table in the original manual. LP4 is cut only for 16-24VAC/DC power input (SK-910RA only); LP3 is cut only to use an external antenna.
| Function | Action |
|---|---|
| Learn mode | Press and hold the switch for 3 seconds. The LED flashes quickly, ready to learn a transmitter code. |
| Clear memory | Press 3 seconds, then when the LED starts flashing, press again for 3 seconds to delete all learned codes. LED flashes twice to confirm. |
| Memory display | Press and immediately release the mode switch. The LED flashes a number of times equal to the codes stored. |
| LED State | Meaning |
|---|---|
| Steady on | Senses a signal from a transmitter button whose code was already learned. |
| Fast flash | In code-learning mode. |
| One flash | A transmitter button code was learned. |
| Two flashes | All previously learned codes for the channel were deleted. |
The receiver's terminal block includes NC/NO/COM relay contacts (SK-910RA) or transistor-ground channel outputs (SK-910RAV/RAV2), plus power input terminals (11-24VAC/DC no-polarity for SK-910RA; 3-13.8VDC GND for SK-910RAV/RAV2). Typical wiring diagrams in the original manual cover: a 12VDC receiver driving a 12VDC appliance (e.g., electromagnetic lock) with positive or negative output selectable via NO/NC; and a 24VAC output driving a motor for garage/gate opener applications. See the original PDF for the full wiring diagrams.
Note (SK-910RAV2): Both channel outputs share the same output mode — you cannot set a 4-second momentary output for channel 1 and a validity output for channel 2 simultaneously.
The optional SK-91ERSD extends RF receiver range up to 1,200' (open air) with existing remotes. It comes with a 9' cable that plugs into the 3-pin antenna port on the RF receiver motherboard. If used with the SK-910RA, the receiver PC board loop marked "LP3" must be cut.
SECO-LARM ENFORCER RF receivers are warranted against defects in material and workmanship for one (1) year from the date of sale to the original customer, limited to repair or replacement of defective parts (return shipping prepaid to SECO-LARM).
SECO-LARM U.S.A., Inc., 16842 Millikan Avenue, Irvine, CA 92606. Tel: 800-662-0800 / 949-261-2999. Fax: 949-261-7326. Email: sales@seco-larm.com. Website: www.seco-larm.com.
Sign up to get the latest on sales, new releases and more …