Full manual for the SECO-LARM ENFORCER SK-1323/SK-2323 series outdoor stand-alone weatherproof keypads, with 1,010 user codes and optional proximity card reader.
Full manual for the SECO-LARM ENFORCER SK-1323 / SK-2323 series Outdoor Stand-Alone Weatherproof Keypads. Covers mullion-style (SK-2323) and sealed-environment (SK-1323) keypads, with or without a built-in proximity card reader (SPQ models). Handles up to 1,010 user codes with 2 independently programmable relay outputs.
| Model | Relay Outputs | Backlit Keys | Proximity Reader |
|---|---|---|---|
| SK-2323-SDQ (mullion) | 2 | Yes | — |
| SK-2323-SPQ (mullion) | 2 | Yes | Yes |
| SK-1323-SDQ (sealed) | 2 | Yes | — |
| SK-1323-SPQ (sealed) | 2 | Yes | Yes |
| Operating voltage | 12–15 VDC |
| Current draw (standby) | 40mA @ 12VDC |
| Current draw (active) | 70mA @ 12VDC |
| Relay outputs (1 & 2) | 1A @ 30VDC, Form C, NO/NC/COM |
| Egress inputs | Input #1 & #2: N.O. ground |
| Door sensor input | N.C. ground |
| Tamper sensor | Optical |
| Operating temperature | -4°~122°F (-20°~50°C) |
| Keypad LED life | 60,000 hours (~6.8 years) |
| Weight | SK-1323: 1lb 2oz (510g); SK-2323: 11oz (312g) |
| Proximity reader frequency | 125kHz (SPQ models only) |
| Proximity reader distance | 1 15/16" (5cm) (SPQ models only) |
| Wire | Function |
|---|---|
| Black | Ground (-) |
| Red | Power (+) 12~15 VDC |
| Brown | Door Sensing Input (N.C.) |
| Orange | Egress Input #1 (N.O.) — triggers Output #1 |
| Yellow | Egress Input #2 (N.O.) — triggers Output #2 |
| Green | Earth Ground |
| Pink / Aqua / Blue | Output #1: COM / N.C. / N.O. |
| Purple / Gray / Blue | Output #2: COM / N.C. / N.O. |
Connect a continuous Earth Ground wire (Green) to a grounding point (grounded metal conduit, cold water pipe, or grounding rod) to prevent static discharge damage. Use 18AWG minimum for earth ground; all other wiring must be at least 22AWG.
Wrong Code Lockout: 5 consecutive wrong codes/cards triggers a 1-minute lockout during which no entries are accepted. Continued button presses/card swipes during lockout extend the lockout period.
| Function | Steps |
|---|---|
| Change Master Code | Enter 3, then new code twice |
| Program Output #1 user code | Enter 3-digit user ID (000–999), then 5-digit code |
| Program Output #2 user code | Enter 4, then 2-digit user ID (00–09), then 5-digit code |
| Delete Output #1 user | Enter user ID, then # |
| Delete Output #2 user | Enter 4, then 2-digit user ID, then # |
| Set Output #1 timer | Enter 1, then 00 for toggle or 01–99 for seconds |
| Set Output #2 timer | Enter 5, then 00 for toggle or 01–99 for seconds |
| Set Output #2 function | Enter 2, then 01 for user codes or 02 for doorbell |
| Set tamper alarm | Enter 6, then 01 (OFF) or 02 (ON) |
| Program Master Card (SPQ) | Enter 7, then swipe the card |
| Delete Master Card (SPQ) | Enter 7, then #, then swipe new card or # to skip |
An Output #1 user code/card may not duplicate the Master Code or any Output #2 code. Likewise Output #2 codes/cards may not duplicate the Master Code or Output #1 codes.
| Action | Entry | Effect |
|---|---|---|
| Delete All Users | 8 8 8 | All user codes/cards deleted. Master Code and other settings remain. |
| Restore Factory Settings | 8 9 9 | Full reset. Master Code returns to 12345. On SPQ models, Output #1 Access Mode resets to proximity cards only. |
Manually resetting a forgotten Master Code: Disconnect power, hold down the # key, reconnect power while still holding #, and after 3 seconds the keypad beeps to confirm — Master Code resets to 12345 (does not affect the Master Card, user codes, or other data).
| Left LED | Right LED | Status |
|---|---|---|
| OFF | Green | Power ON |
| OFF | Orange | Programming Mode |
| Green | Green | Relay 1 activated |
| Red | Green | Relay 2 activated |
| Orange | Orange | Restoring factory defaults |
| Symptom | Fix |
|---|---|
| Keypad won't accept codes or cards | Confirm Output #1 Access Mode is set to accept user codes; check for Wrong Code Lockout (wait 1 minute) |
| Output #2 will not activate | Confirm Output #2 is programmed for the correct function |
| Egress input is not working | Check egress wiring against the wiring diagram |
| Relay output won't stop | Confirm the output isn't set to toggle mode |
| User code won't program | Delete the existing user before programming a new code for that ID |
| Master Code | 12345 |
| Output #1 / #2 user codes | None programmed |
| Output #1 / #2 timer | 1 second |
| Output #2 function | User codes |
| Tamper alarm | OFF |
SECO-LARM warrants this product against defects in material and workmanship for one (1) year from the date of sale to the original consumer customer, limited to repair or replacement (transportation prepaid to SECO-LARM). Void if damage results from misuse, abuse, neglect, unauthorized alteration, or faulty installation.