  • SECO-LARM Enforcer Heavy-Duty Outdoor Access Control Keypad with Proximity Reader (SK-3133-PPQ) — Full Manual

    August 31, 2026 6 min read

    Full manual for the SECO-LARM Enforcer SK-3133-PPQ heavy-duty outdoor access control keypad with built-in proximity reader, covering specifications, wiring, installation, and complete programming instructions.

    Full text manual (for reference)

    Full manual for the SECO-LARM SK-3133-PPQ Enforcer Heavy-Duty Outdoor Access Control Keypad with built-in proximity card reader. Rugged stainless steel faceplate, IP66 weatherproof rating, 12~24 VAC/VDC auto-adjusting operation, and support for up to 1,000 user codes and/or proximity cards.

    Key Features

    • Rugged construction — heavy-duty stainless steel faceplate with coated steel housing, IP66 weatherproof rating, vandal resistant
    • Built-in 125kHz (EM125) proximity card reader, sensing distance 1½" (38mm)
    • 12~24 VAC/VDC operation, auto-adjusting
    • Up to 1,000 user codes and/or proximity cards for output #1, 100 for output #2, and 100 for output #3
    • Up to 50 temporary visitor codes (one-time or 1–99 hour limited-time use)
    • Up to 50 duress codes for output #1, 10 for output #2, 10 for output #3 — triggers a silent alarm if a user is forced to open the door
    • Egress input lets users exit without keying in a code; door sensor input for anti-tailgating operation
    • Interlocking input for connecting to a second keypad
    • Suitable for wall, post, or gooseneck mounting
    • EEPROM memory protects programmed data during power loss; all programming done directly from the keypad — no external programmer needed

    Specifications

    Spec Value
    Operating voltage 12~24 VAC/VDC
    Current draw (standby / keypress / output 1 active / all outputs active) 55mA / 90mA / 105mA / 150mA (max 220mA)
    Output #1 Form C relay, 5A @ 24VDC max.
    Output #2 / #3 Form C relay, 1A @ 24VDC max. each
    K or A, Duress, Interlock outputs 100mA @ 24VDC max. each (transistor ground output)
    Tamper output N.C. dry contact, 50mA @ 24VDC max.
    Proximity reader frequency 125kHz (EM125)
    IP Rating IP66
    Operating temperature -4° to 158°F (-20° to 70°C)
    Operating humidity 5~95% non-condensing
    Faceplate / Housing 1/16" (1.5mm) stainless steel / 5/64" (2mm) anodized powder-coated steel
    Dimensions 5¼" x 7 1/16" x 3⅜" (133 x 180 x 85mm)
    Weight 3-lb 12-oz (1.7kg)

    Parts List

    Keypad with steel box, 2 keys (no replacement keys available — make copies for safekeeping), security wrench, 4 mounting screws, 4 mounting screw anchors, diode, mounting template, and manual.

    Wiring Terminals

    Terminal Description
    12~24 VAC/VDC Power supply connection — observe polarity
    Output 1 N.C./COM/N.O. Relay output, max 5A @ 24VDC
    Output 2 N.C./COM/N.O. Relay output, max 1A @ 24VDC
    Output 3 N.C./COM/N.O. Relay output, max 1A @ 24VDC
    Egress Input N.O. pushbutton to ground — activates output #1 without a code
    K or A output Transistor ground output; jumper-selectable for keypress or alarm signaling
    Duress output Switches to ground to trigger silent alarm when a duress code is entered
    Door Sensor Connect to optional N.C. sensor (e.g. magnetic contact); ground if unused
    Output 1 Inhibit / Interlock Control Connect to matching terminal on a second keypad for interlock operation
    Tamper N.C. N.C. contact, max 50mA @ 24VDC — connect to alarm's 24-hour protection zone

    ⚠ Important Safety Warning

    IF USING THE KEYPAD WITH A MECHANICALLY OPERATED DOOR OR GATE, MOUNT THE KEYPAD AT LEAST 15' (5m) FROM THE DOOR OR GATE TO PREVENT USERS FROM BEING CRUSHED OR PINNED. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.

    • Always disconnect power before servicing the keypad. Do not apply power until all connection wiring is complete.
    • The keypad must be properly grounded using a minimum 22AWG wire connected to the common ground output.
    • Allow at least 2ft (60cm) between this and any other keypads to avoid interference.
    • All wiring and programming should be done by a professional installer.

    Installation Steps

    1. Unlock the keylock on the face of the keypad with one of the included keys.
    2. Remove the tamper screw from the bottom of the keypad using the included security wrench.
    3. Open the faceplate — the hinge lets it hang open during installation.
    4. Remove the 1" wiring hole cover from the back of the keypad housing.
    5. Install the keypad using the included mounting screws and anchors (if needed). For gooseneck stand mounting, use the 4 mounting plate holes on the back of the housing.
    6. Remove the inner plastic back box to access the terminals.
    7. Connect wires according to the wiring diagram.
    8. Finish assembly: replace the inner back box, close and lock the keypad, and replace the tamper screw.

    Jumper Settings

    • Backlit — Full: Dim backlit during standby, full backlit for 10 seconds after any button press.
    • Backlit — Auto: No backlight during standby, full backlit for 10 seconds after any button press.
    • K or A — K (Keypress): Switches to ground for 10 seconds after any button press.
    • K or A — A (Alarm): Switches to ground when an alarm occurs, to trigger an optional auxiliary alarm.

    Quick Programming (Basic Setup)

    For a new master code, a single 4-digit user code for all users (no proximity cards), one output to unlock a door, and a 3-second delay:

    1. Turn off the power-up beeping before the 1-minute period ends.
    2. Enter Programming Mode using the default master programming code 0000.
    3. Change the master programming code to your new code.
    4. Set the user code for User ID #000 to operate output #1 (unlocks the door).
    5. Set the output #1 delay time to 3 seconds (default is 5 seconds).
    6. Exit Programming Mode.

    A flashing amber LED indicates standby mode; a solid amber LED indicates programming mode.

    Security Levels

    1. Card only — Tap a previously-programmed proximity card to activate an output.
    2. User code only — Type a 4-to-8-digit code to activate an output.
    3. Card + common user code — All valid cards share one common code; both must be used together.
    4. Card + unique user code — Each card has its own code; the most secure option.

    Programming Function Reference

    Function Purpose Default
    01 Master programming code 0000 (4–8 digits)
    02 Super user code No default — must be set
    03–05 Common user codes for outputs #1–#3 No default
    10 / 20 / 30 User codes/cards for outputs #1/#2/#3 No default
    40 Visitor codes for output #1 No default
    41–43 Duress codes for outputs #1–#3 No default
    51–53 Output mode/timing for outputs #1–#3 5-second momentary output
    55 Real-time clock No default
    56 Output #1 auto-disable time No default
    60 Wrong-code system lock-up Locks after 10 false tries
    70 User code entry mode Manual entry (# key required)
    71–73 Keypad sounds, output relay sounds, amber LED flashing All enabled
    80–91 Door-forced-open, door-propped-open, door open alarm, egress delay/warning All disabled/immediate

    The Direct Access to Programming (DAP) code 2828 and the system restore code 9999 are fixed and cannot be changed.

    Duress Codes

    Duress codes allow a user to trigger a silent alarm while appearing to unlock the door normally. If a user enters a duress code instead of their normal code, outputs activate as usual, but the duress output simultaneously activates. A duress code cannot deactivate the duress output — only a normal user code/card, super user code, or master programming code can. Duress codes cannot be the same as any other user code (e.g., subtract 1 from the last digit of a real user code).

    Direct Access to Programming (DAP) — Forgotten Master Code Recovery

    1. Disconnect the keypad's power and wait one minute.
    2. Reconnect power — the keypad will beep repeatedly for one minute.
    3. While beeping, press the egress button once to stop the beeping (or briefly jumper the egress input to common ground if no button is installed).
    4. Enter DAP code 2828.
    5. The amber LED turns ON, indicating readiness to program a new master programming code.

    DAP does not reset any other programming — for a full reset, use System Restore (code 9999 while in programming mode).

    Troubleshooting

    Issue Solution
    User code doesn't work Make sure you programmed a User Code, not a Super User or Common User Code. Try deleting super/common user codes and reprogramming.
    Master programming code doesn't work Use the DAP process to reset it.
    Keypad constantly beeps on power-up Normal operation — press 12# to stop the beeping early.

    FCC Compliance & Warranty

    FCC ID: K4E3133PPQ. This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

    Warranty: This SECO-LARM product is warranted against defects in material and workmanship for two (2) years from the date of sale to the original customer. SECO-LARM's obligation is limited to repair or replacement of any defective part if the unit is returned, transportation prepaid.