August 31, 2026 5 min read
Complete installation manual for the SECO-LARM Enforcer E-941SA series Electromagnetic Locks.
Complete installation manual for the SECO-LARM Enforcer E-941SA series Electromagnetic Locks — indoor door-holding maglocks with 600-lb and 1,200-lb holding force options.
| Model | Holding Force* | Operating Voltage | Current Draw |
|---|---|---|---|
| E-941SA-600DPSQ† | 600 lb (272 kg) | 12/24 VDC | 500mA@12VDC, 250mA@24VDC |
| E-941SA-1K2DPSQ† | 1,200 lb (545 kg) | 12/24 VDC | 500mA@12VDC, 250mA@24VDC |
| E-941SA-600PQ‡ | 600 lb (272 kg) | 12/24 VDC | 500mA@12VDC, 250mA@24VDC |
| E-941SA-1K2PQ‡ | 1,200 lb (545 kg) | 12/24 VDC | 500mA@12VDC, 250mA@24VDC |
| E-941SA-1K2PD‡‡ | 1,200 lb (545 kg) | 12/24 VDC | 500mA@12VDC, 250mA@24VDC |
† With status LED, bond sensor, and door position sensor · ‡ With status LED and bond sensor · ‡‡ With status LED, bond sensor, and timer · *Holding force has not been verified by UL.
| Spec | 600-lb | 1,200-lb |
|---|---|---|
| Operating voltage | 12/24 VDC | |
| Current draw @12VDC / @24VDC | 500mA / 250mA | |
| Bond sensor | SPDT relay, 3A@12VDC | |
| Door position sensor | Reed switch, 0.2A@12VDC | |
| Operating temperature | 32°-120°F (0°-49°C) | |
| Magnet dimensions | 9-13/16"x1-11/16"x1" (250x43x25mm) | 10-1/2"x2-7/16"x1-9/16" (267x62x40mm) |
| Armature dimensions | 7-1/4"x1-1/2"x1/2" (185x38x12mm) | 7-1/4"x2-7/16"x5/8" (184x62x16mm) |
| Destructive attack / Line Security / Standby power | Level I | |
| Endurance | Level IV | |
Note: Incorrect input voltage setting may damage the lock. Connect switching devices (e.g. push-to-exit switches) between the power source and the positive terminal — connecting to the negative terminal may cause a delay in unlocking.
The circuit board provides N.O./COM/N.C. bond-sensor relay contacts plus voltage jumper selection (12VDC vs 24VDC). The control device connects between the power supply (12/24 VDC) and the lock. A typical access-control wiring setup includes: outdoor keypad, indoor N/C exit button, outdoor key switch, and the maglock (fail-safe, indoor).
Fail-safe note: A fail-safe lock automatically unlocks when power is lost — important for emergency egress (e.g. fire). All field wiring must be within the protected area.
| Wire Length | 25ft | 50ft | 75ft | 100ft | 150ft | 200ft | 250ft | 300ft | 400ft | 500ft |
|---|---|---|---|---|---|---|---|---|---|---|
| 12VDC @500mA | 20 | 18 | 18 | 18 | 16 | 14 | 14 | 12 | 10 | --- |
| 24VDC @250mA | 22 | 22 | 22 | 20 | 18 | 18 | 16 | 16 | 14 | 14 |
Wire gauge (AWG) shown. For the complete chart, visit www.seco-larm.com.
| Symptom | Solution |
|---|---|
| Doors lock, but can easily be forced open | Check that the electromagnet and armature plates are properly aligned; ensure contact surfaces are clean and rust-free; check power leads with a meter for correct 12/24VDC; confirm the rubber washer is installed and undamaged. |
| Delay in door releasing | The electromagnet already has a built-in MOV to prevent interference — do not add a second diode. Ensure the control device is connected between the power source and the positive terminal of the lock. |
Important: Incorrect mounting exposing the enclosure to rain or moisture could cause dangerous electric shock, device damage, and void the warranty. Installers are responsible for proper installation and sealing, and for compliance with all applicable national, state, and local laws/codes.
California Proposition 65 Warning: This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. See www.P65Warnings.ca.gov.
Limited Lifetime Warranty (US): Warranted against defects in material and workmanship for the lifetime of the product under normal service. SECO-LARM's obligation is limited to repair or replacement of defective parts (transportation prepaid by purchaser). Void if damage results from misuse, abuse, neglect, unauthorized repair/alteration, improper usage, or faulty installation. Outside the US, the warranty is 1 year.
SECO-LARM U.S.A., Inc., 16842 Millikan Avenue, Irvine, CA 92606. Phone: (949) 261-2999 / (800) 662-0800. Email: sales@seco-larm.com. Web: www.seco-larm.com.