  • PulseWorx HAI UPB Wall Switch/Dimmer & Auxiliary Switch (35A00, 37A00-1) — Installation Instructions

    August 31, 2026 8 min read

    Installation and operating instructions for the HAI UPB Wall Switch and Auxiliary Switch (models 35A00-1, 35A00-1CFL, 35A00-3, 37A00-1), covering wiring, UPB Setup Mode, and compatible dimmable CFL/LED bulbs.

    Full text manual (for reference)

    Installation and operating instructions for the HAI UPB™ Wall Switch and Auxiliary Switch — models 35A00-1 (600W Dimmer), 35A00-1CFL (600W CFL/LED Dimmer), 35A00-3 (600W Non-Dimming Switch), and 37A00-1 (Auxiliary Switch) — covering wiring, local rocker operation, UPB setup, de-rating, and compatible dimmable bulbs.

    Read Before Installing

    This HAI UPB™ Wall Switch and Auxiliary Switch is intended for installation in accordance with the National Electrical Code and local codes and regulations. It is recommended that a qualified electrician perform this installation. Retain these instructions for reference.

    To reduce the risk of overheating and possible damage to other equipment, when configured as dimming-capable, do not install to control a receptacle, a motor-operated appliance, or a transformer-supplied appliance. This product is for indoor use only. Connect only copper wire to this device.

    Important Notes Prior to Installation

    • All HAI UPB™ Wall Switches require a neutral (white) connection wire.
    • Be sure that all power to the load has been disconnected by turning off the circuit breaker. Installing an HAI UPB™ Wall Switch or Auxiliary Switch with power on may expose you to dangerous voltage and may damage the device.

    Overview

    HAI UPB™ Wall Switch: Allows local control of lighting via a Decora-style rocker switch. Incorporates UPB™ two-way powerline communication technology for remote control by UPB-compatible controllers, and can transmit UPB messages (including current light level) when turned on, off, brightened, or dimmed. The HAI Dimmer Switch can store up to 16 preset light levels and fade rates to create lighting scenes. The HAI Non-Dimming Switch controls loads such as fluorescent lights and ceiling fans.

    HAI Auxiliary Switch (37A00-1): An optional companion device for multi-way circuits, with a Decora-style rocker switch that controls the load in the same manner as the Wall Switch's rocker.

    HAI UPB Wall Switch — Wire Connections (Figure 1)

    • LED Indicator — Top (ON/BRIGHT), Bottom (OFF/DIM)
    • BLACK — Line
    • WHITE — Neutral
    • RED — Load
    • YELLOW — Control
    • GREEN — Ground
    • Air-Gap Switch Lever with lever groove

    HAI Auxiliary Switch — Wire Connections (Figure 2)

    • LED Indicator — Top (ON/BRIGHT), Bottom (OFF/DIM)
    • BLACK — Line
    • GRAY — *Neutral (for red indicator)
    • BLUE — *Neutral (for blue indicator)
    • YELLOW — Control

    *Connecting the blue and/or gray wire to neutral sets the color of the LED indicator: connect blue for a blue indicator, gray for a red indicator, or both for a magenta indicator. The blue/gray wire may be connected to neutral or earth ground — neutral is recommended.

    Installation Procedure

    1. Be sure all power to the load has been disconnected by turning off the circuit breaker.
    2. If applicable, remove the faceplate and existing wall switch from the wall box and disconnect its wires. Identify the "Line," "Neutral," "Load," and "Traveler" (if applicable) wires.
    3. Be sure the air-gap switch lever on the HAI UPB Wall Switch is fully open.
    4. Remove Âľ" of insulation from each wire on the HAI UPB Wall Switch. Install by connecting wires per the wiring configuration (see Figure 5 wiring diagram).
    5. Install any optional HAI Auxiliary Switch per the wiring configuration.
    6. After all connections are made, be certain all wire connectors are firmly attached and there is no exposed copper.
    7. Gently place the wires and HAI UPB Wall Switch into the wall box with the LED at the top of the device. Using the supplied screws, attach the switch to the wall box.
    8. Before installing the faceplate, restore power to the circuit, then fully close the air-gap switch lever.
    9. After testing the HAI UPB Wall Switch and Auxiliary Switch for proper local operation, install a Decora-style faceplate over each switch.

    Wiring Notes

    • All HAI UPB Wall Switches require a neutral (white) connection.
    • The Line (black) wire must be accessible for installation of all HAI Auxiliary Switches; it may be connected to either phase of the 120/240V supply.
    • Multi-way circuits (one or more Auxiliary Switches connected to a Wall Switch) let a group of switches control the same light or set of lights.

    Air-Gap Switch

    The HAI UPB Wall Switch has an air-gap switch lever that removes all power from the load for safe switch installation and light bulb replacement. To activate: using a fingernail, pry open the lever at the groove and swing it fully open so it's perpendicular to the bottom rim. After servicing, push the lever fully closed (parallel to the bottom rim) — it must be fully closed for normal operation.

    Changing Switch Color

    The switch plate is supplied white; additional colors are available from your HAI distributor. To change: disconnect the switch from all power, then use a small-bladed screwdriver to gently depress the upper and lower latch on one side while lifting up on the plate; once released on one side, remove the plate from the other side. Align the latches of the new switch plate to the mounting plate openings and gently snap into place.

    HAI Wall Switch De-Rating

    In two-gang installations, no de-rating is needed for the 35A00-1, 35A00-1CFL, or 35A00-3. In three-gang installations, each switch must be de-rated from 600W to 500W.

    Model Device Maximum Load Next to One Dimmer Next to Two Dimmers
    35A00-1 600W 600W 500W
    35A00-1CFL 600W 600W 500W
    35A00-3 600W 600W 500W

    HAI Dimmer Switch Operation (Factory Default)

    The HAI Dimmer Switch has a Decora-style rocker switch. Many configurable items can be set using the UPB™ UPStart configuration software; below is the factory default operation.

    Rocker Event Top Rocker Bottom Rocker
    Single-Tap Brightens the light to 100% (on) at default fade rate and restarts auto shut-off timer (if applicable). Fades the light to 0% (off) at default fade rate.
    Double-Tap Snaps the light to 100% (on) and overrides auto shut-off. Snaps the light to 0% (off).
    Hold Starts fading (brightening) the light towards 100% at default fade rate and restarts auto shut-off timer (if applicable). Starts fading (dimming) the light towards 0% at default fade rate.
    Release Stops brightening the light and restarts auto shut-off timer (if applicable). Stops dimming the light.

    HAI Non-Dimming Switch Operation (Factory Default)

    Rocker Event Top Rocker Bottom Rocker
    Single-Tap Turns the load on and starts auto shut-off timer (if applicable). Turns the load off.

    LED Indicator

    The HAI UPB Wall Switch's multi-color LED is normally lit blue when the load is off, and turns off when the load is on or set above 0%. The LED flashes magenta while the auto shut-off timer is running (if the configured LED option is "always off," the LED remains off during the timeout period). If used, the LED on the HAI Auxiliary Switch is always lit.

    HAI Auxiliary Switch Operation

    The HAI UPB Wall Switch can connect to one or more HAI Auxiliary Switches to create multi-way lighting circuits. Each Auxiliary Switch's rocker controls the load the same way as the connected Wall Switch's rocker. When connected, its LED stays continually on while power is applied.

    Setup Mode

    To configure the HAI UPB Wall Switch using an HAI controller or a PC running UPB UPStart configuration software, put it into Setup Mode:

    Step Operation
    1 Tap the rocker switch quickly 5 times. The switch will flash the lighting load once and blink its LED blue to indicate Setup Mode.
    2 The switch will automatically exit Setup Mode after 5 minutes.

    Note: Setup mode and blink mode take precedence over auto shut-off. If the auto shut-off timer is running when setup or blink mode starts, the timer resets and is disabled until setup/blink mode expires.

    Reset to Factory Default Settings

    Step Operation
    1 On the switch you want to reset, tap the rocker switch quickly 5 times.
    2 The switch flashes the lighting load once and blinks its LED blue to indicate it's ready to be reset.
    3 Tap the rocker switch quickly 10 times to reset to factory default.
    4 The switch flashes the lighting load once and blinks its LED red to indicate it has been reset.
    5 Tap the rocker switch once more to stop the LED from blinking.

    Compatible Dimmable CFL / LED Bulbs

    The following dimmable CFL and LED bulbs (by manufacturer/model) are approved for use with these dimmers:

    Type Manufacturer Model Wattage (W)
    CFL EcoSmart 2R3015DIM 15
    CFL EcoSmart ES5CCDF052 5
    CFL EcoSmart ES5M10123 23
    CFL EcoSmart ES5R315DIM35K / ES5R315DIM50K 15
    CFL Feit BPESL15T/DM / BPESL23T/DIM 15 / 23
    CFL GE / Energy Smart FLE15/2/DV/R30, FLE15HT3/2/DV/SW, FLE26/2/DV/R40, FLE26HT3/2/DV 15 / 26
    CFL Litetronics 16AE5L092725, 18185K085141, 18185K088141, 18505A10111, 18BR5E09152 5-27
    CFL Litetronics / EarthMate E05129LW, E2752AJLW 5 / 27
    CFL Neptun / EarthTronics 61920-ADIM, CF24SW1BDIM 20 / 24
    CFL Phillips EL/A PAR38, EL/A R30 DIM, EL/A R40 DIM 16-20
    CFL Sylvania CF5EL/A15/827/DIM/BL, CF5EL/B10/827/C/ADP/DIM/BL, CF14EL/R20/DIM, CF14EL/TWIST/DIM, CF19EL/BR40/DIM, CF24EL/TWIST/827/DIM/RP 5-24
    CFL TCP 2R2014DIM, 40123, 4R3016TD, CCA05 5-23
    CFL ULA SDR23W2P-R30 DIM 23
    LED Cooper Lighting - HALO ML706830 14
    LED Cree CR6-0210E, CR6-0323E 12
    LED EcoSmart ECO-GU24-575L-YOW, G2510003-005, R2010010-013 8-12
    LED Lemnis Lighting Pharox 300 6
    LED Phillips 12E26A60, 3E12B11-E, 6E26R20, 7E26PAR20-E, 8E26A60 3-12.5
    LED Sylvania LED8PAR20/DIM/827/FL36, LED8PAR20/DIM/827/NFL25, LED8PAR20/DIM/830/NFL25/HVP, LED10PAR30/DIM/SG830/WSP15, LED11PAR30/DIM/SG/830/SP10 8-11
    LED TCP LDA153WH30K 3
    LED Toshiba 218-50053 7.8
    LED Utilitech 0171150, 0338802, 0352280 2-7.5

    CFL = Compact Fluorescent Lamp. LED = Self Ballasted, Light-Emitting Diode.

    Specifications

    Spec 35A00-1 35A00-1CFL 35A00-3
    Incandescent Loads Dimming Yes Yes Yes (configurable)
    Inductive Loads Dimming Yes Yes Yes (configurable)
    Fluorescent Loads Non-Dimming Yes (configurable) Yes (configurable) Yes
    Power Maximum Dimming 600W / 600VA 600W / 600VA 600W / 600VA
    Current Maximum Non-Dimming 5A 5A 5A
    Connections 18 GA 18 GA 18 GA
    LED Indicator Yes Yes Yes
    Dimensions 4.1 x 1.75 x 1.45 in 4.1 x 1.75 x 1.45 in 4.1 x 1.75 x 1.45 in
    Weight 0.25 lb. 0.25 lb. 0.25 lb.
    Mounting Standard J Box Standard J Box Standard J Box
    Input Power 120 ± 12 VAC 120 ± 12 VAC 120 ± 12 VAC
    Input Frequency 60 ± 3 Hz 60 ± 3 Hz 60 ± 3 Hz
    Operating Temperature -40°F to 104°F -40°F to 104°F -40°F to 104°F

    Note: It is normal for this switch to make a slight buzzing sound during operation. It is also normal for the switch and wall plate to feel warm to the touch.

    Limited Warranty

    HAI warrants this product against defects in material and workmanship, under normal use and service, for two (2) years from the date of purchase. During the warranty period, HAI will repair or replace, at its sole option, a product that fails due to defect. This warranty does not cover removal/reinstallation costs, normal wear, damage while in your possession (other than damage caused by defect or malfunction), improper installation (including failure to follow written instructions), alterations, misuse, or abuse. Remedies provided are the sole and exclusive remedies; HAI is not liable for incidental or consequential loss or damages. See www.homeauto.com for the complete HAI Warranty (USA policy). Implied warranties, including merchantability and fitness for a particular purpose, are limited to two years from purchase date. This warranty gives specific legal rights, which vary from state to state; some limitations may not apply.

    For warranty/repair service within the continental United States, send the defective unit carefully packaged, postage prepaid, with a description of the trouble, name, return address, and phone number to: HAI, Repair Department, 4330 Michoud Blvd, New Orleans, LA 70129. HAI pays return shipping via normal ground service. Outside the continental U.S., contact an Authorized Distributor for repair/replacement instructions.