  • Leviton DOS05/DVS05 Single Pole & 3-Way Motion Activated Light Control — Instruction Manual

    August 31, 2026 6 min read

    Instruction manual for the Leviton DOS05 (Occupancy/Vacancy) and DVS05 (Vacancy) Single Pole and 3-Way Wide View Motion Activated Light Controls.

    Full text manual (for reference)

    Instruction manual for the Leviton DOS05 (Occupancy/Vacancy Sensor Switch) and DVS05 (Vacancy Sensor Switch) — Single Pole and 3-Way Wide View Motion Activated Light Controls, indoor use only. Higher-capacity siblings of the DOS02/DVS02, supporting 3-way switch applications.

    Ratings

    120VAC, 60Hz — 600W Incandescent, 5A Resistive, 300W LED and CFL, 400VA ELV/MLV, 1/4 HP Motor.

    Warnings & Cautions

    • To avoid fire, shock, or death: turn off power at the circuit breaker or fuse and test that power is off before wiring.
    • To avoid personal injury or property damage, do NOT install to control a receptacle or a load exceeding the specified rating.
    • Install and use in accordance with electrical codes and regulations. Consult an electrician if unsure.
    • Clean with a damp cloth and mild soap only — no disinfecting products, foggers, sprays, or atomized cleaners.
    • No user-serviceable components — do not attempt to service or repair.
    • Use with copper clad wire only.

    Features

    • 180° sensing angle, 30 x 30 ft area of coverage
    • Adjustable ambient light (DOS05 only), time delay, and area of coverage controls
    • Indicator light shows device status
    • Adjustable time delay: 1, 5, 10, or 20 minutes, plus a 5-second test mode
    • Temporary Bypass mode (disables Auto-On) — DOS05 only
    • Supports both Single Pole and 3-Way switch wiring configurations

    Mounting Location

    The device responds to temperature changes. Do NOT mount directly above a heat source, where hot/cold drafts blow directly on the sensor, or where unintended motion (e.g. hallway traffic) falls within the sensor's field of view.

    Tools needed: Slotted/Phillips screwdriver, electrical tape, cutters, pliers.

    Installation

    Warning: Turn off power at the circuit breaker or fuse and test that power is off before wiring.

    1. Identify your wires. A Neutral wire (if present) or a Ground wire is required for operation. Single Pole and 3-Way configurations are both supported; consult an electrician if your wiring doesn't match the standard configurations.
    2. Single Pole, Neutral NOT present: connect Line/Load (Black), Ground (green sleeved wire), and the second Line/Load (Black) per the diagram. Line and load wires can be wired interchangeably.
    3. Single Pole, Neutral present: remove the green sleeve from the white wire, then connect Traveler, Neutral, Line, Load, and Ground per the diagram.
    4. 3-Way, Neutral NOT present: The sensor installs in the wallbox where the load wire is present (Sensor Wallbox), with a second wallbox holding a standard 3-way switch. Wire Traveler 1, Traveler 2, Line, Load, and Ground between the Switch Wallbox and Sensor Wallbox per the diagram. To control the load from the 3-way switch, toggle once to turn the load ON and twice to turn it OFF.
    5. 3-Way, Neutral present: Same concept as above but with Neutral routed through both wallboxes in addition to Traveler 1, Traveler 2, Line, Load, and Ground.
    6. Note: The sensor must be installed in the wallbox location where the load wire is present.
    7. Test and mount: restore power and wait 10-20 seconds for the sensor to power up.
      • DOS05: lights turn ON automatically with the first motion detected after warm-up, or by pressing the push pad.
      • DVS05: press the push pad — lights should turn ON.
      If lights don't turn on, see the troubleshooting table below. Turn off power at the breaker again before final installation — gently push wires into the wall box, screw the light control to the box, install the wallplate, then restore power.

    Operation

    • RED indicator light: flashes any time motion is detected.
    • GREEN locator/indicator light: turns ON when the load is OFF.
    • Press either the TOP or BOTTOM of the button to turn the load ON/OFF manually.

    Programming

    How to Change Settings

    In order to... Do this... Indicator light will...
    Enter programming mode Hold TOP and BOTTOM button for 5 seconds GREEN light solid ON for 5 seconds (if nothing happens, already in programming mode)
    Change settings (Timer, Sensitivity, Ambient Light) Single press TOP button to advance to next setting RED light blinks to indicate the column selected (e.g. Column 1 = 1 blink/sec)
    Change options within a setting Single press BOTTOM button to advance to next option GREEN light blinks to indicate option selected (Option 1 = 1 blink/sec, Option 2 = 2 blinks/sec, etc.)
    Save and exit settings Hold either TOP or BOTTOM button for 5 seconds GREEN light solid ON for 5 seconds

    If there is no activity for 30 seconds, the device automatically exits programming mode and changes are NOT saved. Multiple settings can be changed and saved in a single session.

    Setting Types and Options (defaults in bold)

    Option Column 1: Timer Column 2: Sensitivity Column 3: Ambient Light (DOS05 only)
    1 1 minute Low (50% range) Low light level
    2 5 minutes Medium Medium light level
    3 10 minutes High High/brightest light level
    4 20 minutes All settings to default Disabled — turns ON for all light levels

    Occupancy vs. Vacancy Mode (DOS05 only)

    • Occupancy mode: for automatic ON/OFF lighting control. Turns light ON when a user walks into view while the light is OFF and it's darker than the set ambient light level, OR when the TOP/BOTTOM button is pushed. Light turns OFF when no motion is detected for the programmed time period, OR the button is pushed. Ambient light options: 1-Low (turns on if room is darkest), 2-Medium, 3-High, 4-Disabled (always turns on).
    • Vacancy mode: for Manual ON, Automatic OFF lighting control. Light turns ON only when the button is pushed. Turns OFF when the button is pushed, when no motion is detected for the programmed time period, or if the user moves around within 30 seconds of the light turning off.

    Occupancy/Vacancy Switch (DOS05 only): Remove the color kit and wallplate to access the OCC/VAC toggle.

    Advanced Modes

    Mode To Enable Behavior
    Test Mode Press and hold TOP of button for 5 seconds. Exit: press TOP or BOTTOM, or auto-exits after 2 minutes. Turns the load on for 5 seconds each time motion is detected. RED light blinks 1x/2 sec. Locator LED disabled while active.
    Temporary Bypass Mode (occupancy sensors only) Press and hold BOTTOM of button for 5 seconds. Exit: press TOP or BOTTOM. Ignores motion, keeping the light/load off. GREEN light double-flashes every 2 seconds.
    Programming Mode Hold TOP and BOTTOM of button for 5 seconds. GREEN light solid ON for 5 seconds.

    Sensing Area Coverage

    Horizontal field of view: Major motion coverage ~900 sq ft, minor motion coverage ~400 sq ft, extending out to roughly 30 ft.

    Vertical field of view: Effective coverage extends from a mounting height of about 40-48 inches out to 20-30 ft.

    Changing Device Color

    Remove the existing color kit cover and replace with the desired color option.

    Troubleshooting

    Issue Suggested Adjustment
    Lights don't operate with push pad and RED indicator doesn't blink when motion is present Verify wiring connections to the sensor.
    Lights don't switch ON when motion is detected (DOS05) Motion may be beyond sensing range — move closer to the switch; adjust the light level lower (Option 3/2/1 or disable).
    RED light blinks (indicating motion) but load doesn't turn on Could be due to ambient light setting, or check the Occ-Vac switch is in OCC position.
    Lights always stay ON Check time delay settings vs. actual on-time; confirm no motion in the coverage area by covering the lens for the selected time; check the switch isn't near a heat source or detecting motion from an adjacent area — relocate if so.
    Lights don't turn ON (DVS05) Make sure the control is installed correctly, power is ON, and the light bulb is functional.

    FCC Statement

    This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: it may not cause harmful interference, and it must accept any interference received, including interference that may cause undesired operation. Tested and complies with Class B digital device limits under Part 15, providing reasonable protection against harmful interference in residential installations. If interference occurs, try reorienting the antenna, increasing separation, using a different circuit outlet, or consulting a technician. Unauthorized modifications could void the user's authority to operate the equipment.

    Warranty & Support

    Limited 5-Year Warranty. For full warranty details, visit www.leviton.com, or call 1-800-824-3005 for a printed copy. Patents at www.leviton.com/patents.

    Technical assistance: 1-800-824-3005 (USA) or 1-800-405-5320 (Canada). Canadian warranty/returns: Leviton Manufacturing of Canada Ltd, Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9.