  • OPTEX IVPC-DI Door Interface — Settings and Installation Guide

    August 31, 2026 3 min read

    Settings and installation guide for the OPTEX IVPC-DI door interface unit, part of the IVPC video intercom system, covering pairing, wiring, relay output, and troubleshooting.

    Full text manual (for reference)

    Settings and Installation Guide for the OPTEX IVPC-DI Door Interface — part of the IVPC video intercom system. The IVPC-DI can operate as a chime, a dry relay output, or both, and is commonly used to switch power to a maglock or door strike.

    LED Indications

    State LED
    Power on (before pairing) Blinking red
    Power on (pairing completed) Solid white
    Pairing success (tone 1) Blinking blue
    Pairing failure (beeps) Blinking red
    Tone/unlock (tone 1–5, or mute) Single red blink

    Parts include: pairing switch, mode switch, LED indicator, speaker, volume +/- button (mute + 3 steps — a confirmation beep sounds when muted), relay output terminal, and power input terminal. Accessories: screws & anchors, mounting plate.

    What to Expect (3 Steps)

    1. Mounting and wiring: mount the IVPC-DI, connect power wires and signal wires to external devices.
    2. Pairing: pair the IVPC-DI to the IVPC-DS (door station) using the IVPC-MS or the OPTEX Vision App.
    3. Operation check: test the performance of the IVPC-DI and connected external devices.

    Step 1 — Mounting and Wiring

    1. Turn off all equipment, including the external devices of the system.
    2. Remove the main unit from the mounting plate (slide up, pull off).
    3. Pass the wires through and fix the mounting plate to the wall.
    4. Wire to the terminals: N.O. (e.g. strike), COM, N.C. (e.g. maglock); power 10–24V AC/DC. Polarity is not a concern.
    5. Mount the main unit on the mounting plate (attach, slide down).
    6. Turn all equipment back on.

    Relay Output Wiring Examples

    • Door Strike: N.O. and COM terminals to the power supply and strike.
    • Magnetic Lock: COM and N.C. terminals to the power supply and maglock.

    Step 2 — Pairing

    1. Press the doorbell on the IVPC-DS to initiate pairing with the IVPC-DI.
    2. After accepting the call, press the icon shown on-screen to start the wizard for the IVPC-DI.
    3. Confirm the correct number of paired chimes is shown at the completion of the wizard.

    Note: One IVPC-DS can pair with up to four IVPC-DI units, but only one IVPC-DI can be assigned to operate its relay — the other three are limited to sounding their chimes (all chimes sound simultaneously, with the same tone type). Example use case: one IVPC-DI operates the front door lock while a second serves as a chime in a back room.

    Unlock Setting

    1. Press the "Unlock Setting" button.
    2. Select which chime will also function as a door release.

    An "Unlock" marking is displayed on the assigned IVPC-DI once configured.

    Step 3 — Operation Check

    • Chime sound: Push the doorbell button on the IVPC-DS, then confirm the chime tone on the IVPC-DI.
    • Door strike: Push the door release button on the IVPC-MS or OPTEX Vision App screen, then confirm the door has been released.

    Communication uses a 916 MHz signal between the IVPC-DS and IVPC-DI, and Wi-Fi between the IVPC-DS/MS/OPTEX Vision App.

    Troubleshooting

    Status Check Point Solution
    Sounds too loud/low Confirm sound is not muted Adjust with the Volume +/- button on the IVPC-DI
    IVPC-DI does not respond Check supplied power is within spec; check pairing was to the correct IVPC-DS Device ID If indicators work, check pairing target ID
    Door will not unlock Confirm wiring of the relay output; confirm the IVPC-DI is set to release a door lock Correct wiring (mind N.O./N.C.); set to open via IVPC-MS or OPTEX Vision App
    Door will not unlock (duration) Check the relay output duration matches the door lock system spec Select from 1, 5, 10, 30, or 60 seconds via IVPC-MS or OPTEX Vision App

    Additional troubleshooting is available online at optexamerica.com/faq. Test the total operation after installation is complete. Dispose of used products and batteries per local government regulations.

    Specifications

    Frequency 916 MHz
    Power 10 to 24V AC/DC, 500 mA max
    Chime tone 5 types selectable (set via IVPC-MS or OPTEX Vision App)
    Chime volume Approx. 80dB max, 3 levels + mute
    Relay output duration 1 / 5 / 10 / 30 / 60 seconds, selectable
    Relay output rating 1C relay, 1A max, 50V AC / 24V DC
    Operating temperature 0°C to 40°C (32°F to 104°F)
    Operating humidity < 90% (no condensation)

    Warranty

    18 months from the week of manufacture, identified from the serial number (format YYWWAAAAAZZZZ). Warranty does not cover physical/electrical modification, improper use, accident, natural disaster, or environmental events. Contact OPTEX technical support before arranging a return: warranty-returns@optexamerica.com, tech@optexamerica.com, or 800-966-7839.