  • On-Q/Legrand lyriQ High Performance Keypad Volume Control with IR (AU1000-xx) — Installation Sheet

    August 31, 2026 4 min read

    On-Q/Legrand lyriQ High Performance Keypad Volume Control with IR (AU1000-xx) — Installation Sheet

    Full text manual (for reference)

    Instruction/installation sheet for the On-Q/Legrand lyriQ™ High Performance Keypad Volume Control with IR (P/N AU1000-xx) — a Category 5-wired, whole-house audio keypad volume control with built-in dual 20W-per-channel Class D amplifiers, part of the lyriQ™ Multi-Room Audio System.

    Overview

    The High Performance Keypad Volume Control combines with other lyriQ™ system components and source equipment (receiver, CD player, etc.) to build a whole-house audio system. It uses a single Category 5 cable to carry audio signals, control data, and IR for remote control, and has two on-board 20W/channel Class D amplifiers — enough for outdoor or large-room use. It looks almost identical to the standard lyriQ™ Keypad Volume Control (F7394-xx), but is distinguished by parentheses around the music-note icon and an RJ45 jack (rather than a 110-style punchdown block) on the rear.

    Controls & Connections

    • Front panel: Volume Up/Down (with 5 green bar-graph LEDs), Source (with 4 green source LEDs), Mute (red status LED), plus an IR target window and tri-color status LED.
    • TB2 (Speaker Output): spring-loaded, up to 14-gauge wire, for connecting evoQ™ speakers (L+, L-, R+, R-).
    • TB3 (Line Out): spring-loaded, up to 14-gauge wire, mono-summed and filtered through an 80Hz low-pass filter — for powered subwoofers or an external amplifier (unamplified; volume control still governs output level).
    • TB1 (Power In): spring-loaded, up to 14-gauge speaker wire (16/4 recommended, paired with Cat5) run from a power distribution module (P/N AU1001) in the enclosure. Red/white wires to the plus (red) side, black/green wires to the minus (black) side.
    • J1: RJ45 jack for the Category 5 data/control connection, wired to the T568A standard.

    Installation

    Install at "Rough-in" (before drywall) and "Trim-out" (after drywall/paint):

    • Rough-in: run one Category 5 cable and one 16/4 speaker wire from the enclosure to a single-gang outlet box or mud ring at each volume control location.
    • Trim-out: terminate the Cat5 cable with an RJ45 plug (T568A standard) into jack J1. For power, strip 3/8" of insulation from each of the four conductors and insert red/white into the TB1 plus side, black/green into the minus side (the two plus and two minus terminals are tied together, provided in pairs for wiring flexibility). Connect speakers to TB2 and any subwoofer/external amp to TB3, observing L+/L-/R+/R- polarity markings. In the enclosure, terminate the Cat5 run with an RJ45 plug into the matching zone output jack of the lyriQ™ audio distribution module, and wire the 16/4 power cable the same way as at the keypad end.
    • Test all connections before mounting; use the included screws to install into a standard single-gang box (20 in³ or larger recommended if not using a low-voltage mounting ring).

    Make sure power supplies are disconnected from the lyriQ™ Audio and Power Distribution Modules before wiring, and always terminate Cat5 to the T568A standard — mismatched standards can damage equipment.

    Operation

    • On/Off: press any button to turn on; press and hold Mute to turn off.
    • Source select: press Source repeatedly to cycle through sources; volume automatically ramps down then back up on a source change.
    • Volume: Up/Down buttons, 40 steps.
    • Mute: tap the Mute button.
    • Back-light adjust: hold Volume Up + Down together, then use Volume Up/Down to set level; press Source or Mute to exit (or wait 10 seconds).
    • Temporary Do Not Disturb: double-tap Mute (status LED glows dim red); the keypad won't respond to whole-house commands while in this mode. Press any button to exit.
    • Whole-House Source Control / Party Mode: press Mute + Source together (IR/status LED blinks orange). All button presses on this keypad are then relayed to every active keypad in the system. Press-and-hold Source while in this mode turns on and syncs all keypads to the currently selected source; double-tapping Source syncs all keypads directly to this keypad's current source. Exits automatically after 10 seconds of inactivity, or by pressing-and-holding Mute + Source again.

    Installer Configuration (Installer Mode)

    Enter Installer Mode by holding all four buttons (Volume Up, Down, Mute, Source) for ~5 seconds (status LED flashes green then red). Within Installer Mode, press Source to select a setting group, then use Volume buttons to adjust:

    • LED #1 — Permanent DND: Bar Graph LED #1 = enabled, #2 = disabled.
    • LED #2 — Turn-On Volume level.
    • LED #3 — Maximum Volume the user cannot exceed.
    • LED #4 — IR Receiver Adjust: #1 = normal IR, #2 = IR output disabled (remote controls only this unit), #3 = IR target disabled (useful for ganged volume controls).
    • LED #1+#2 — Balance (left/right).
    • LED #1+#3 — Back Light Mode: #1 = on, #2 = off.
    • LED #1+#2+#3+#4 — Reset to factory defaults (press Volume Up or Down).

    Firmware version check: with the unit on, press Mute, Volume Down, Volume Up, Volume Up, and repeat the sequence 3 times; the firmware revision then displays on the Source and Volume Bar Graph LEDs.

    Safety Precautions

    • Only qualified personnel should service, move, or modify system components.
    • Installation must conform to all local building and electrical codes.
    • Do not power the system until all components are installed and wiring is properly terminated.
    • Unplug the power transformer(s) at the enclosure before any wiring changes.
    • Keep components away from heat sources (HVAC ducts, stoves, etc.) and moisture — moisture exposure voids the warranty.
    • Clean cover plates only with a damp cloth — no vacuum, liquid, or aerosol cleaners.