August 31, 2026 4 min read
Instruction and installation sheet for the On-Q/Legrand lyriQ™ Standard Keypad (AU7394-xx), covering wiring, rough-in/trim-out installation, operation, and installer settings for the lyriQ Multi-Room Audio System.
Instruction/installation sheet for the On-Q/Legrand lyriQ™ Standard Keypad (P/N AU7394-xx), an integral component of the lyriQ™ Multi-Room Audio System. Combined with a Source Input Unit, Distribution Module, speakers, and source equipment, it creates a whole-house audio system. Document IS-0391 REV. D. Available in White (-WH), Light Almond (-LA), Ivory (-IV), or Black (-BK).
The lyriQ™ Standard Keypad uses Category 5 wiring to distribute audio signals, control information, and IR for remote control. It has two on-board Class D amplifiers for clean sound output, plus the ability to control other keypad volume settings throughout the house. It can be combined with the lyriQ™ High Performance Keypad (AU1000-xx) in the same system.
The front panel includes push buttons for VOLUME UP/DOWN (with five green Volume Bar Graph LEDs), SOURCE (with four green Source Selection LEDs), and MUTE (with a red status LED), plus an IR target window and tri-colored status LED. The rear panel has an RJ45 jack (J1) for connection to the lyriQ™ Audio Distribution Module, plus spring-loaded TB2 speaker output terminals (L/R, +/-, up to 14 gauge wire) and TB1 Line Out terminals for a powered subwoofer or external amplifier. Recommended for indoor use only.
Best accomplished at two stages during new construction: "Rough-in" (before drywall) and "Trim-out" (after drywall is installed and painted). Always follow TIA-570-B wiring standards for Category 5 cable; maintain a minimum 12" separation between Cat5 cable and any 120VAC cabling.
Applies to AU5009-xx, AU5010-xx (Studio Keypads), AU7394-xx, and AU1000-xx. Enter Installer Setting Mode by quickly pressing Mute, Volume Up, Volume Down, Volume Down — twice in sequence.
| Setting | Options |
|---|---|
| Whole House Enable/Disable | Default (enabled) or Disable — used for outdoor spaces, nurseries, offices, etc. that shouldn't be disturbed by whole-house commands. |
| Turn-On Volume | Default ~10% full volume; Variable (0–50%); or "Last volume" (resumes at the level it was last turned off at). |
| Maximum Volume | Default 100%; Limited Maximum Volume down to 50% — useful for bathrooms, bedrooms, children's rooms. |
| IR Target / IR Output | Default (remote enabled); IR Output Disabled (in-room only, for above-normal RF interference); IR Target Disabled (keypad ignores remote, for extreme interference environments). |
| Grouping (Studio Keypads only) | Default (not grouped); Member of a Group; Master of a Group — used with Integration Module when cascading AU7396 Single Source Modules. |
| Balance Setting | Default (middle); adjustable left/right for listening position. |
| IR Repeat Transmission | Default Multi-Burst (40kHz & 56kHz); or fixed 40kHz / 56kHz for devices that don't respond to multi-burst (cable/satellite boxes are often 56kHz). |
| Restore Defaults | Returns all settings to factory defaults — useful for troubleshooting installer-setting-related issues. |