  • NuTone Overture Smart Plug (BIAQSP100P) — Installation Instructions

    September 08, 2026 3 min read

    Installation instructions for the Broan-NuTone Overture Smart Plug, used to control HRV/ERV/Make-Up Air Damper systems and supply fans via the Overture app.

    Full text manual (for reference)

    Installation instructions for the Broan-NuTone Overture™ Smart Plug (part no. 1103436) — a Wi-Fi-connected smart control for HRV/ERV/Make-Up Air Damper systems and supply fans, used with the Broan-NuTone Overture app.

    Control Specifications

    • cULus Listed
    • 120 VAC 60 Hz line power
    • Requires NEMA 5-15R or 5-20R receptacle
    • Maximum load: 15A resistive, 15A inductive, ½ HP motor, 3A incandescent
    • Dry Contact Class 2 — 24VAC 60Hz or 12VDC, 40VA max load
    • Operating temperature: 32-95°F (0-35°C)
    • Rated impulse voltage: 1500V

    Safety Warnings

    • Before installing, switch power off at the service panel and lock the disconnecting means to prevent accidental power-on. If it can't be locked, attach a prominent warning tag.
    • All electrical work must comply with local codes and the National Electrical Code, including fire-rated construction codes. This product MUST be grounded.
    • Use copper wire only.
    • Do not wire hot — risk of serious injury from electrical shock.
    • Install only in a UL Listed NEMA 5-15R or 5-20R receptacle, easily accessible. Do not use with a wall-switch-controlled receptacle.
    • Enclosure protection rating: IP20. Not intended for unheated warehouses, garages, or similar cold locations.
    • Avoid water and wet locations.
    • Do not attempt to disassemble, repair, or modify the device — risk of shock and voided warranty.
    • Warranty is void if miswired.

    HRV/ERV/Make-Up Air Damper Installation

    1. Turn off power and lock out the service panel before wiring the control to your Fresh Air System.
    2. Verify Smart Plug orientation before installation — note the "TOP" direction shown on the Smart Plug label.
    3. Location notes: Place the Smart Plug within range of your Wi-Fi router or access point (approximately 100 feet); avoid physical obstructions and radio interference.
    4. Make electrical connections following the wiring diagrams below or in the Broan-NuTone Overture App. Use wire nuts, and ensure both the Smart Plug and the Fresh Air System are properly grounded. Wire terminals accept #20 AWG to #16 AWG solid or stranded wire rated for at least 75°C.
      • Strip wire to 0.5" length, press the wire release mechanism, and insert the bare wire into the screw terminal opening as far as possible.
      • Release the wire release mechanism, making sure the wire remains under the clamp.
      • Do not reuse wire formed into a "J" loop or wrapped around screw threads — the terminal is designed for straight wire insertion only.
    5. Route wires to the HRV/ERV/Make-Up Air Damper.

    Supply Fan Installation

    1. Plug the power cord into the Smart Plug receptacle.
    2. Download the Broan-NuTone Overture App for step-by-step setup instructions to connect your Smart Plug (scan the QR code on the printed instructions to go to the App Store).

    Note: When power is applied, the Smart Plug may require approximately 30 seconds to boot up and be ready to function.

    Wiring Diagrams

    Low Voltage Option — Make-Up Air Damper wired through a 24V transformer: Black/Line, White/Common, Green/Ground.

    Corded Option — Make-Up Air Damper with 24V transformer and corded power connection: same color code (Black/Line, White/Common, Green/Ground).

    For HRV/ERV systems, wiring differs slightly between AI Series and Non-AI Series units — refer to the terminal labels NO, C, NC, I, OC, OL, Y, R, G, B on the unit and match to the diagram in the full PDF or the Overture App.

    Regulatory Information

    FCC ID: 2ADLL-1103436 | IC: 2143B-1103436. Complies with Part 15 of FCC Rules and Innovation, Science and Economic Development Canada's licence-exempt RSS standards. Contains a Bluetooth® radio (Bluetooth SIG, Inc. trademark, used under license).