August 31, 2026 4 min read
Installation instructions for the Napco Magnum RP1054e backlit digital display keypad, for use with Napco MA1000e, MA1008e, MA1010, and MA854 control panels.
Installation instructions for the Napco RP1054e Keypad — a backlit alphanumeric keypad for use with Napco MA1000e, MA1008e, and MA1010 control panels, and as a replacement keypad for MA854, MA1008-series, and MA1010-series panels.
The RP1054e features a large 7-segment alphanumeric display for control-panel information and zone identification. Installation runs on only four wires. This manual covers installation only — refer to the accompanying User's Guide (OI160) for keypad functions/operation, and to the control panel's installation manual for panel mounting, wiring, and programming.
| Spec | Value |
|---|---|
| Operating Voltage | 9.0–13.0Vdc (supplied by control panel) |
| Current | 40mA typical (subtract from panel's available standby current) |
| Wiring Length | 1 keypad: 1000ft max · 5 keypads: 300ft max (using #22AWG wire) |
| Dimensions | 4-3/8" x 5-7/8" x 1-1/16" (H x W x D) |
| Keypad Wire Color | MA854 | MA1000e/MA1008e | MA1008 | MA1010 |
|---|---|---|---|---|
| Yellow | 1 | 9 | 5 | 6 |
| Green | 2 | 10 | 6 | 7 |
| Red | 3 | 7 | 3 | 3 |
| Black | 4 | 8 | 4 | 4 |
| White (x2) | To normally-open momentary-contact remote panic switch(es) | |||
Remote Panic: splice the two white wires to a normally-open momentary-contact pushbutton switch; additional panic buttons can be wired in parallel. If not used, insulate both white leads (a short across them triggers a panic alarm). In UL installations, remote panic buttons must be located in the same room as the keypad.
Note: Be careful not to splash solder onto the keypad circuit board or components when soldering connections.
The RP1054e supports Fire/Police/Auxiliary panics. Cut Jumper E to enable them. If enabled:
If used as a replacement keypad in MA854 or MA1008 systems (which lack F/A/P panic), or MA1010 systems without F/P/A panic, Jumper E must remain intact.
Backlighting requires no additional wiring; the keypad is dimly backlit by default.
Hold the indicated key for about 2 seconds (until a beep sounds):
| Key | Function |
|---|---|
| 1 | Bell/Battery Test |
| 2 | Display Bypass |
| 3 | Display Status |
| 4 | Instant Protection |
| 5 | Chime |
| 6 | Telco Test; Manual Download |
| 7 | Fault Find |
| 8 | Program |
| 9 | Reset |
| B | Alarm History |
If a system trouble isn't corrected, it reappears after about 3 minutes. Hold Reset Key [9] to temporarily check zone status and/or arm the system.
| Key | Function |
|---|---|
| 1 / 6 | PRIOR — go back to previous location |
| 2 / 3 | NEXT — advance to next location |
| 4 | DATA UP — cycle data (1–9, 0, B–F) ascending |
| 7 | DATA DOWN — cycle data descending |
| 5 | CLEAR — clear data from selected location |
| 8 | EXIT — enter Dealer Program Code within 10 seconds to verify and exit |
| B | SET LOCATION — enter a 3-digit location number |
To reassemble the keypad after installation: hang the top of the front panel onto the hooks in the rear case, then push in firmly at the bottom until the retainer tabs snap into place. (If difficulty is encountered, push the retainer tabs up slightly using a screwdriver, as when removing.)
Napco Security Systems, Inc. — 333 Bayview Avenue, Amityville, NY 11701. Sales/Repairs/Technical Service: 800-645-9445. Technical Service Direct Line: 800-645-9440.