August 31, 2026 3 min read
Full user manual for the Aeotec aërQ Z-Wave Gen7 Temperature and Humidity Sensor (ZWA039), covering pairing, LED indicators, association groups, and configuration parameters.
User manual for the Aeotec aërQ Temperature and Humidity Sensor (ZWA039), a Z-Wave Gen7 battery-powered sensor that records ambient temperature and humidity and warns of conditions ideal for mould growth.
Confirm with your Z-Wave Gateway/Controller manufacturer that this device is compatible — most Z-Wave gateways are generically compatible with Switch and Sensor type devices.
| Push Type | Function | Description |
|---|---|---|
| Long press, 10s | Reset | Initiates local device reset. Green LED flashes once per second for 5 seconds. Solid green after 10s = success; solid red = failure. |
| Short press | Ideal Mould Environment Sense + Wakeup Report | Forces an immediate reading and reports danger level via Binary Sensor Report if humidity is high; also sends a Wakeup Report so queued controller commands can be delivered. |
| 3x short press | Sequence | Used to pair or unpair the sensor. |
Find the 2 indented arrows on the side of the sensor. Place your thumb and index finger on them and push in — if mounted, pull the sensor to separate it from the base; if not mounted, grip the bottom half with your other hand and pull the two halves apart.
Once paired, the sensor measures air parameters every 15 minutes. Tapping the Tamper Switch once forces an immediate measurement and updates the danger-level indication.
| State | Indication |
|---|---|
| Unpaired, entering pairing | Red and Green blink every second (may not be visible if pairing is fast) |
| Pair success | Solid Green for 1.5 seconds |
| Pair failed (timeout) | Solid Red for 1.5 seconds |
| Paired — good environment | Green LED |
| Paired — ideal for mould growth | Red LED |
| Low battery | Red blinks 3x, Green blinks once |
This battery-powered device sleeps deeply to conserve power. It wakes periodically to send a Wakeup Report, during which the controller can deliver queued commands. To manually wake it: unlatch from the mounting base and tap the button once.
Push the button for 20 seconds. Use only when the primary controller is inoperable, as this can leave a phantom node on your network.
| Group | Max Nodes | Description |
|---|---|---|
| 1 | 5 | Lifeline |
| 2 | 5 | Temperature High Trigger (params 5, 10) |
| 3 | 5 | Temperature Low Trigger (params 6, 9) |
| 4 | 5 | Humidity High Trigger (params 7, 12) |
| 5 | 5 | Humidity Low Trigger (params 8, 11) |
| 6 | 5 | Air Temperature |
| # | Parameter | Default | Range |
|---|---|---|---|
| 1 | Minimum temperature change to report | 20 (2.0°) | 0 (disabled) or 1-100 (×0.1°) |
| 2 | Minimum humidity change to report | 7% | 0 (disabled) or 1-20% |
| 4 | Periodic report interval | 43200 sec (12h) | 0 (disabled) or 900-65535 sec |
| 5 | Temperature upper watermark | 0 (disabled) | 1-1000 (×0.1°) |
| 6 | Temperature lower watermark | — | 0 (disabled) or 200-1000 (×0.1°) |
| 7 | Humidity upper watermark | 0 (disabled) | 10-100% |
| 8 | Humidity lower watermark | — | 0 (disabled) or 1-90% |
| 13 | Mould-notification humidity offset | 0 | 0-10% (default triggers above 70% humidity) |
| 64 | Temperature scale | 1 (Celsius) | 1 = Celsius, 2 = Fahrenheit |
| 255 | Reset parameter | 0 | 1 = reset settings; 1431655765 = full factory reset + notification |
Parameters 9-12 define the BASIC SET command values (0-255) sent when temperature/humidity watermarks are crossed, for driving associated dimmers/switches.