Installation instructions for the Leviton Vizia RF+ VRCZ4-MR 4-Zone Controller with Switch (Single Pole), a Z-Wave enabled controller for managing up to 4 lighting zones.
Installation instructions for the Leviton Vizia RF+™ VRCZ4-MR 4-Zone Controller with Switch (Single Pole) — a Z-Wave enabled controller that manages up to 4 lighting zones from one location.
Vizia RF+ components communicate via Radio Frequency (RF) as Z-Wave enabled routers, re-transmitting signals from device to device until the intended target is reached. This 4-Zone Controller is designed for zone-enabled Z-Wave products. For mixed device groups that don't support the zone command class, use the Leviton 4-Scene Controller (VRCS4) instead.
Press and hold buttons 1 and 3 for ~10 seconds until the LED turns Amber then solid Red, blinking red twice — release to complete the reset. Caution: factory reset does NOT exclude the device from the network — the exclusion procedure must still be performed at the controller, or the network may become slow to respond.
| Symptom | Possible Cause |
|---|---|
| Lights flickering | Bad lamp connection, or wires not secured firmly under terminal screws. |
| Light doesn't turn on | Tripped breaker/fuse, burned-out lamp, or unwired lamp neutral. |
| Locator LED doesn't light | Tripped breaker/fuse; check wiring if powered but LED is off. |
| Zone controller doesn't operate lights | Check association; verify controller was updated properly; re-program zone. |
| LED turns solid Red | Check association; ensure each device is within 70 ft (21m) of another device. |
Limited 5-year warranty covering defects in materials and workmanship under normal use. Contact Leviton Manufacturing Co., Inc., Quality Assurance Department, 201 North Service Road, Melville, NY 11747, or Techline at 1-800-824-3005.