0

Your Cart is Empty

  • Add description, images, menus and links to your mega menu

  • A column with no settings can be used as a spacer

  • Link to your collections, sales and even external links

  • Add up to five columns

  • Jasco/Enbrighten ZW3012 (56590) — In-Wall No-Neutral Smart Dimmer Manual

    September 08, 2026 6 min read

    Complete instruction manual for the Jasco/Enbrighten In-Wall No-Neutral Smart Dimmer (Model ZW3012/56590), a Z-Wave dimmer switch requiring no neutral wire.

    Full text manual (for reference)

    Instruction manual for the Jasco/Enbrighten In-Wall No-Neutral Smart Dimmer (Model ZW3012 / SKU 56590) — a Z-Wave smart dimmer switch that installs without a neutral wire connection.

    Overview

    The ZW3012 is a Z-Wave-certified in-wall dimmer that turns lights ON/OFF and adjusts brightness manually or remotely via a Z-Wave controller. It requires no neutral wire, works with incandescent and most dimmable CFL/LED bulbs, and can be installed as a single-pole switch or expanded to 3-way/4-way wiring using up to four compatible add-on switches (model 46560).

    Key Features

    • No neutral wire required
    • Manual or remote (Z-Wave) ON/OFF and dimming control
    • Single-pole or 3-way/4-way installation with up to four add-on switches (model 46560)
    • Compatible with incandescent and most dimmable CFL/LED bulbs
    • Interchangeable paddle switch (white and light almond paddles included)
    • Z-Wave certified for simple pairing and home automation integration
    • Screw terminal installation — line (hot), load, and ground connections; traveler wire required for 3-way/4-way
    • Advanced configuration options adjustable via a Z-Wave controller that supports the configuration command class

    Important Safety Warnings

    • Shock hazard: Turn OFF power to the branch circuit at the service panel before wiring. All connections must be made with power OFF.
    • Install in accordance with the National Electric Code (US) or Canadian Electrical Code local regulations. If unsure, consult a qualified electrician.
    • For indoor use only.
    • Only use to control incandescent or dimmable CFL/LED bulbs — do not exceed ratings.
    • Do not use to control receptacles, motor-operated appliances, fluorescent lighting fixtures, or transformer-supplied appliances.
    • Do not use to control any device where unintended operation could cause unsafe conditions (heat lamps, sun lamps, etc.).
    • Switch mode is designed to mimic an ON/OFF switch. This dimmer is rated and constructed for lighting loads only — cannot be used with fans or motor loads.
    • Z-Wave enabled devices should never be used to supply power to or control the ON/OFF status of medical or life-support equipment.

    Installation

    Wire Gauge Requirements

    This dimmer is rated for and intended to only be used with copper wire. Use 14 AWG or larger wires suitable for at least 80°C for line (hot), load, ground, and traveler connections. Strip insulation 5/8 in. (16 mm) for attachment using the enclosure's holes. UL specifies the tightening torque for the screws is 14 Kgf-cm (12 lbf-in).

    Single-Switch Wiring

    1. Shut off power to the circuit at the circuit breaker or fuse box, and verify power is OFF before continuing.
    2. Remove the wallplate and switch mounting screws, then carefully remove the existing switch from the box without disconnecting the wires.
    3. Note the four screw terminals on the dimmer: A. GROUND (green/bare), B/C. LINE or LOAD (black), D. TRAVELER (red/other, only for 3-way installations). Match these to the wires connected to the existing switch, then disconnect and label the old wires.
    4. Connect the green or bare copper ground wire to the GROUND terminal.
    5. Connect the black wire from the light to either LINE/LOAD terminal.
    6. Connect the black wire from the electrical service panel (hot) to the other LINE/LOAD terminal.
    7. The traveler terminal is only used for 3-way or 4-way wiring — do not use it in a 2-way system (one switch, one load).
    8. Insert the dimmer into the switch box, being careful not to pinch or crush wires.
    9. The dimmer must be independently mounted (vertical position only). Secure with the supplied screws and mount the wallplate.
    10. Reapply power at the fuse box/circuit breaker and test the system.

    Multi-switch (3-way/4-way) wiring: Refer to the add-on switch (model 46560) manual for instructions. Connecting the traveler terminal of this dimmer to a standard switch will cause damage or improper function — do not connect the traveler wire or apply power until add-on switches are correctly installed.

    Changing the Paddle Color

    Optional, and done before installation:

    1. Lift the air gap tab at the base of the paddle.
    2. Push side tabs in on one side, then the other, to release the paddle. Lift the cover up and off.
    3. Put the new paddle onto the dimmer by inserting the air gap and side tabs, snapping securely into place.

    Basic Operation

    Manual Control (Front Panel Rocker)

    • Press and release the top of the rocker to turn the fixture ON.
    • Press and release the bottom of the rocker to turn the fixture OFF.
    • Press and hold the top of the rocker to increase brightness.
    • Press and hold the bottom of the rocker to decrease brightness.

    Cycle LED Light (Status Indicator)

    The LED below the dimmer acts as a guide light or status indicator. Cycle through options by pressing up three times and down once quickly.

    1. LED ON when the load is OFF (guide light in the dark) — default
    2. LED ON when the load is ON (indicates the dimmer is ON)
    3. LED always OFF
    4. LED always ON (illuminates the dimmer in the dark)

    LED Bulb Brightness Thresholds

    Performance varies between dimmer brands and LED bulb types, which can cause flickering or strobing. This dimmer allows setting minimum and maximum brightness thresholds to compensate:

    • Minimum dim threshold: Press OFF button four times, then ON button once quickly. Light starts at the most recent minimum dim level (default 1%). Press the rocker until the bulb reaches desired brightness without flickering. The LED stops flashing 10 seconds after release to confirm the setting. (Z-Wave configuration parameter 30, size 1 byte, values 1–99, default 1)
    • Maximum brightness threshold: Press ON button four times, then OFF button once quickly. Light starts at the most recent maximum brightness (default 99%). Press the rocker until desired brightness is reached without flickering. (Z-Wave configuration parameter 31, size 1 byte, values 1–99, default 99)

    Only bulbs designed as dimmable should be used on a dimmer. Check the bulb package or contact the manufacturer to confirm dimmability. See www.ezzwave.com for a list of recommended CFL/LED bulbs.

    Switch Mode

    Switch mode mirrors the behavior of a simple ON/OFF switch without adjusting brightness.

    • Engage switch mode: Press ON button five times, then OFF button five times. The LED blinks five times to confirm.
    • Disengage switch mode: Press ON button five times, then OFF button five times. The LED blinks five times to confirm.
    • When switch mode is engaged, manual/remote/voice ON commands turn the light to 100% brightness; any OFF command turns it to 0%.

    Z-Wave Network Configuration

    Adding the Device to a Z-Wave Network

    1. Follow the instructions for your Z-Wave certified controller to add a device to the network.
    2. Once the controller is ready, press and release the top or bottom of the smart dimmer rocker.
    3. If prompted for the S2 security code, enter the 5-digit PIN from the QR code/security number on the box or product label.

    SmartStart-enabled products can also be added by scanning the QR code with a controller providing SmartStart inclusion — no further action is needed, and the product is added automatically within 10 minutes of being powered on near the network.

    Removing the Device

    1. Follow the instructions for your Z-Wave certified controller to remove a device from the network.
    2. Once the controller is ready, press and release the top or bottom of the smart dimmer rocker.

    Factory Reset

    Only use if the network's primary controller is missing or otherwise inoperable. Quickly press ON (top) button three times, then immediately press the OFF (bottom) button three times. The LED flashes ON/OFF five times when completed successfully.

    Association Groups

    This device supports the Association Command Class (3 groups, 5 nodes max per group):

    • Group 1 — Lifeline, Multi-level Switch report
    • Group 2 — Basic Set, controlled with the local load
    • Group 3 — Basic Set, controlled by double-pressing the ON/OFF button

    This product is Z-Wave interoperable and can be added to any Z-Wave network alongside certified devices from other manufacturers. All non-battery operated nodes act as repeaters to increase network reliability regardless of vendor.

    Specifications

    Spec Value
    Model ZW3012 / 56590
    Power 120VAC, 60Hz
    Signal frequency 908.4/916MHz
    Maximum loads 1-gang 600W, 2-gang 500W, 3-gang 400W incandescent; 300W dimmable CFL/LED
    Minimum load 8W incandescent, 5.5W dimmable CFL/LED
    Range Up to 150 ft. line of sight between the wireless controller and closest Z-Wave receiver module
    Operating temperature 32–104°F (0–40°C)
    Mounting Independently mounted, vertical position only
    Use Indoor use only
    FCC ID / IC U2ZZW3012 / 6924A-ZW3012

    Warranty

    Jasco Products Company warrants this product to be free from manufacturing defects for five years from the original date of consumer purchase. This warranty is limited to repair or replacement of this product only and does not cover consequential or incidental damage to other products. Contact U.S.-based Consumer Care at 1-800-654-8483 (option 1), Monday–Friday, 7AM–8PM Central Time, or visit www.byjasco.com/support for the most up-to-date product support, accessories, and electronic (PDF) manuals.