Technical guide covering relay configuration, jumper settings, and sensor specifications for the Global Caché Flex Link Relay & Sensor Cable (GCFLCRS).
The Global Caché Flex Link Relay & Sensor Cable is an input/output cable for use with the iTach Flex. It provides relay outputs and sensor inputs for controlling and monitoring a variety of devices. Configuration is via hardware jumpers and a software API. External devices connect via push-release terminal blocks, and the enclosure can be mounted directly on a DIN rail for simple integration with external relays.
The relay outputs are fully configurable to operate as several standard relay types and can control a wide range of devices. The sensor inputs are configurable to detect contact closure as well as AC and DC voltage.
The board provides terminal connector blocks physically grouped as relay outputs and sensor inputs. Each port within a block uses 2 terminals — for example, Port 1 uses terminals 1 and 2, Port 2 uses terminals 3 and 4. Relay ports can be configured as individual SPST relays, or logically grouped with other ports to form other common relay configurations. Input ports are individually configurable for either voltage sensing or contact closure mode.
The relay outputs can be configured (via hardware jumpers and the software API) to operate as one of three common relay types:
Each relay configuration has a configurable default state, allowing relays to be set up as normally open or normally closed.
| Rating | Minimum | Maximum |
|---|---|---|
| Voltage | — | 24 Volts |
| Current | — | 500mA |
Sensor inputs allow sensing of contact closure as well as presence of voltages between ±3V and ±24V RMS. Each terminal block provides 2 input ports (2 terminal pins per port), and each input port can be configured independently.
Voltage-Sense Configuration: Disconnect all jumpers, or store them vertically in the bottom two positions of the jumper pins. In this state, inputs read as open ('0') until a voltage is applied, at which point the indicator LEDs turn on and the inputs read as closed ('1').
Contact Closure Configuration: Place jumpers vertically on the top two pins of each column. In this configuration, inputs read as closed ('1') until contact closure occurs, at which point the input state becomes open ('0').
| Characteristic | Minimum | Maximum |
|---|---|---|
| Input Voltage AC/DC | ±3V (RMS)* | ±24V (RMS) |
| Input Current | 200µA | — |
| Input Low-to-High Response** | 1.5ms | 3ms |
| Input High-to-Low Response** | 110ms | 250ms |
| Contact Closure Detection Source Current | — | 2mA |
*For AC signals at low frequencies, the minimum input voltage becomes a function of frequency.
**These response times are for the relay/sensor board hardware detection only and do not include network and processing delays.