Instruction Sheet for the ELK-M1KPNAV Navigator Touchscreen Keypad, a 3.5" color LCD touchscreen keypad for the Elk M1 Control System, covering mounting, wiring, and setup.
Instruction Sheet for the ELK-M1KPNAV Navigator Touchscreen Keypad, a 3.5" color LCD touchscreen keypad for the Elk M1 Control System, connecting via the RS485 data bus.
Navigator is a stylish touch screen keypad for use with the M1 Control System. It features a touch-sensitive 3.5" LCD color display with bright, easy-to-use graphic icons and softkeys. Connection to the M1 panel is via the RS485 bus, making it simple for new or retrofit installations.
Navigator is designed and manufactured in Australia for Elk Products by Ness Corporation.
| Spec | Value |
|---|---|
| Screen Size | 3.5" diagonal |
| Resolution | 320 x 240 pixels – landscape |
| Connection | 6-pin plug-in "flying lead" cable |
| Operating Voltage | 13.8 VDC |
| Current Draw | ~30mA idle (backlight on low, sounder silent); ~55mA fully active |
| Dimensions | 4.25"W x 3.38"H x 0.59"D |
| Color | Silver back plate with white front bezel (black or silver front bezels sold separately) |
Note: M1 firmware v5.2.8 or later is required for Navigator to synchronize and display the names of Areas, F Keys, Lights, Outputs, and Tasks. ElkRP software v2.0.10 or later is recommended when programming an M1 system that includes a Navigator.
Navigator can be wall-mounted without a pre-wire box. If a pre-wire box is used, it must be a single-gang electrical box designed for "New Work," and should be installed sideways (horizontal). Single-gang boxes designed for "Old Work" have a wider outer trim dimension and may not be suitable — test fit before installation.
An optional surface box (ELK-M1BBKN) is available for use on concrete or block (non-hollow) surfaces, or where a wire raceway is needed.
Splice the four wires on the plug-in cable to the Data Bus Cable wires from the control. Use "B" connector splices, or solder and tape the connections.
4-conductor data bus cable (CAT5 strongly recommended). Connector J1 has two pins marked "RS485" — a jumper shunt is provided for placement on these pins ONLY if this keypad is the last device on the data bus. Do not place the jumper on any other pins of J1.
Optional programmable output from keypad: connect the load (e.g., LED, relay, 50mA max) to the Brown wire (+) and Black/Neg wire (−).
Optional programmable zone input from keypad: connect to the Blue wire and Black/Neg wire, with a 2200 Ohm EOL resistor (N.C./N.O. as required). The optional zone number and output number are determined by the keypad address, per the table below.
| Keypad Address | Zone # | Output # |
|---|---|---|
| 1 | 193 | 193 |
| 2 | 194 | 194 |
| 3 | 195 | 195 |
| 4 | 196 | 196 |
| 5 | 197 | 197 |
| 6 | 198 | 198 |
| 7 | 199 | 199 |
| 8 | 200 | 200 |
| 9 | 201 | 201 |
| 10 | 202 | 202 |
| 11 | 203 | 203 |
| 12 | 204 | 204 |
| 13 | 205 | 205 |
| 14 | 206 | 206 |
| 15 | 207 | 207 |
| 16 | 208 | 208 |
Note: Connector TB1 (6-pin) is for the 6-wire keypad cable assembly. TB2 (3-pin) is for a special RS232 cable (sold separately) used by an optional PC software utility for flashing firmware and/or quickly setting up the Installer Information page — call Elk for details.
If using CAT5/CAT6 cable and an ELK-M1DBH Hub, use the Brn/Wht → Red(+), Wht/Brn → Black(−), Org/Wht → Green(A), Grn/Wht → White(B) pairs. The blue pair is not used.
On power-up, the Start-Up screen displays the keypad number enrolled in the panel, the firmware version, the M1 serial number, and the data bus address only if the keypad currently has an address set. The Start-Up screen displays until all current status data is collected from the M1 panel; it then moves to the Main User screen.
If the keypad address doesn't match one currently enrolled in the M1 (or has never been enrolled), the message "Please enroll keypad into panel" displays. Perform a bus enrollment using an already-enrolled keypad or the ElkRP Remote Program software.
If a keypad address isn't currently set, the message "Please Set Keypad Address" displays at the bottom. Otherwise, "Waiting to connect to panel" displays until Navigator receives valid data from the panel. Once the keypad receives valid data (and is enrolled), it displays "Synchronising Panel Status."
Each keypad connected to an M1 must have its own unique address, distinct from any other keypad on the system.
Default Keypad button: clears the keypad address, M1 serial number, function key names, task names, lighting names, output names, and area names. It does NOT clear installer information.
EXIT: press this button or the red "X" in the top right corner to exit the Set Keypad Address screen.
The Main User Screen is displayed once startup and synchronization complete.
If programming changes are made to the M1, perform a manual Synchronise to update Area, Task, Lighting, Output, and Function (F) Key names. On the Main Screen, press "MENU," then "Next Page" to locate the Synchronise button. Press "Synchronise" and then "START" to synchronise and upload all the names.
Contact information for the installation company can be entered and stored in Navigator, providing customer contact information for system expansions, future sales, or customer service. This screen displays whenever the "Information" button is pressed on the Menu Screen. Installer Information can only be edited from the Installation Programming Menu, accessible using the Installer Program Code. To return to the Menu screen, press "MENU"; to return to the Main User screen, press the red "X" or "Exit Menu."
To use Navigator for programming the M1 Control, press "Installation Programming" on the Main Menu screen. Installer Programming Menus are organized on 2 pages. Detailed programming information for the M1 can be found in the M1 Installation & Programming Manual.
Manufacturer: Elk Products, Inc., PO Box 100, Hildebran, NC 28637 USA.