September 08, 2026 3 min read
Installation instructions for the ELK-319PB1 Heavy Duty 1 Button Panic device, a wireless panic transmitter for police, medical, or other emergency alarm activation.
Installation Instructions for the ELK-319PB1 Heavy Duty 1 Button Panic device, a wireless panic transmitter for police, medical, or other emergency alarm activation.
The ELK-319PB1 is a wireless heavy duty 1-button panic device that transmits to an alarm panel when pressed. It can be used for police, medical, or other alarm activation. The device also transmits low-battery status as needed and is powered by a single replaceable 3VDC lithium coin-cell battery.
Compatible with Elk's 319MHz Receivers/Panels, as well as many other panels operating on the 319.5MHz frequency that adhere to the ITI/Interlogix protocol.
| Spec | Value |
|---|---|
| RF Frequency | 319.5 MHz |
| Compatibility | ELK-319 Receivers/Panels & other panels on 319.5MHz using the ITI/Interlogix protocol |
| Battery Type | One (1) 3VDC lithium coin-cell battery (Panasonic or Varta model CR2450) |
| Operating Temp Range | 32°F to 120°F (0°C to 49°C) |
| Storage Temp Range | -30°F to 140°F (-34°C to 60°C) |
| Relative Humidity | 95% non-condensing |
| Dimensions | 3.0" x 2.0" x 0.7" in. (L x W x D) |
| Accessories | Belt Clip, Lanyard Clip, Wall Mount Bracket |
General guideline — refer to your receiver/panel instructions for complete details.
Note: Tighten the bottom case screw after removing the battery isolation tab.
There are three ways to carry the Panic Button:
Note: The belt clip must be installed on the panic device for it to fit into the wall mount bracket.
All wireless sensors should be thoroughly tested after installation and programming.
Establishes a baseline for the distance the panic sensor will nominally operate away from the control or receiver.
If the alarm system is centrally monitored, always notify them before operational testing.
Low Battery trouble is transmitted when the sensor's battery needs replacement. Replace the battery within 7 days of a low battery indication.
Battery Warning: Risk of fire, explosion, and burns. Do not attempt to recharge or disassemble. Do not incinerate or expose to heat above 212°F (100°C). Dispose of used batteries properly. Keep away from children.
Complies with FCC Part 15, Class B digital device rules, and Industry Canada license-exempt RSS standards. FCC ID: 2ABBZ-RF-Panic-319. IC: 11817A-RFPANIC319. Per FCC RF exposure requirements, maintain a minimum separation distance of 20 cm from the general population.
This wireless sensor is warranted to be free from defects in materials and workmanship for 2 years from date of manufacture, excluding batteries (batteries used with wireless devices are not warranted). Manufacturer disclaims all other warranties to the extent permitted by law; some states do not allow exclusion of implied warranties.
Manufacturer: Elk Products, Inc., 3266 Hwy 70, Connelly Springs, NC 28612.
Sign up to get the latest on sales, new releases and more …