September 08, 2026 5 min read
Installation and operation manual for the ELK-6020 Wireless Slim-Line Door & Window Sensor.
Installation and operation instructions for the ELK-6020 Wireless Slim-Line Door & Window Sensor — a two-way wireless reed switch sensor designed for narrow jamb door and window applications, compatible with Elk transceivers such as the ELK-M1XRFTW.
The ELK-6020 features Elk's Two-Way Technology, offering on-demand status updates plus extended range and long battery life. It works with any Elk Wireless Transceiver or Control that accepts Elk's two-way technology. Each time the 6020 transmits, it sends a unique TXID identifier and a Loop number.
| Frequency | 902–928 MHz frequency hopping |
| Tamper | Field-installed plunger for front and back detection |
| Auto-Sync Type | B |
| Dimensions | Sensor: 0.71"W x 3.4"L x 0.8"D · Magnet: 0.57"W x 1.5"L x 0.6"D |
| Maximum Operating Gap of Reed | 1/2" |
| Operating Temperature | 14° to 104°F (-10° to 40°C) |
| Relative Humidity | 5–95% non-condensing |
| Battery | 3.6V ER14250 Lithium |
| Unique TXID Code | Over 1 million combinations |
Avoid mounting on metal surfaces whenever possible, as metal can negatively affect wireless operation. Observe temperature and humidity specs; do not use in high moisture/humidity areas. Always pre-test the sensor in its intended location before permanent mounting.
Note: Adhesive tape cannot be used for UL Listed installations.
To use the case/wall tamper option, insert the rubber actuator (from the hardware bag) into the post near the center of the baseplate. Tamper auto-enables when the sensor is snapped onto the baseplate; tamper alerts are sent if the sensor is opened or removed. Once enabled, tamper can only be disabled by removing the battery, removing the actuator, and re-powering the sensor without the actuator present.
After all wireless zones have been enrolled, proceed to Menu 5 - Zone Definitions to program the name, zone type, and options. Note: M1 only allows Zones 17–160 for wireless zones (max 144 wireless sensors), always starting at Zone 17 (Group 2), enrolled in groups of 16.
It is more time-efficient in ElkRP to program the zone definitions (name, type, options) before moving to Wireless Setup for entering TXID and loop number.
A two-color LED behind the plastic cover (front & center) displays feedback each time the sensor is violated or restored. It can be difficult to see this LED under direct sunlight.
Per UL, a complete test of the security system and all zones should be performed once a week. Zones may be walk-tested using the M1 Keypad Menu 3 - Walktest Area.
A Low Battery signal is reported to the control when the sensor battery needs replacing.
Battery Warning: Risk of fire, explosion, and burns. Do not attempt to recharge or disassemble. Do not incinerate or expose to heat above 212°F (100°C). Dispose of used batteries properly. Keep away from children. Do not reverse the battery polarity.
The ELK-6020 Wireless Slim-Line Door & Window Sensor is warranted to be free from defects in workmanship for a period of 2 years from date of manufacture. Batteries used with wireless devices are not warranted. Elk makes no other express or implied warranty, including merchantability or fitness for a particular purpose, with regard to batteries used with wireless devices. Refer to Elk's website for the full warranty statement.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: TMAELK-6020. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Manufacturer: Elk Products, PO Box 100, 3266 US Hwy 70 West, Hildebran, NC 28637 · Phone 828-397-4200 · Fax 828-397-4415 · www.elkproducts.com