  • DataComm Connected Media Box — Installation Instructions (45-8017-1, 45-8011-1P, 45-8021-1S, 45-8031-1C)

    August 31, 2026 3 min read

    Installation instructions for the DataComm Connected Media Box (part numbers 45-8017-1, 45-8011-1P, 45-8021-1S, 45-8031-1C), an in-wall enclosure for TV power sources and AV wiring.

    Full text manual (for reference)

    Instruction and installation sheet for the DataComm Electronics Connected Media Box — a low-voltage in-wall enclosure for mounting TV power sources, phone/video modules, and cable pass-throughs. Part numbers: 45-8017-1, 45-8011-1P, 45-8021-1S, and 45-8031-1C.

    Parts Included

    • Connected Media Box Enclosure
    • Trim Ring
    • Two (2) Power Supply Mounting Brackets
    • Two (2) 20" Hook and Loop Fasteners
    • Four (4) Metal Wood Screws

    Tools Needed

    • Flat blade and Phillips head screwdriver
    • Drill (optional)
    • Utility knife

    Feature Identification

    • A) Knock-outs for standard-sized conduit.
    • B) Retrofit mounting holes for old work installation.
    • C) Industry standard mounting holes for phone and video modules made by DataComm Electronics and other major manufacturers.
    • D) Knock-out for a metal outlet or J-Box (must have UL and/or ETL approval).
    • E) Mounting brackets to hold a One Connect Box or other TV power sources.
    • F) Two (2) large knockouts for access to USB ports.

    Installation Instructions

    1. Location Selection

    The Connected Media Box fills an entire stud bay horizontally. Make sure the box will fit either below the TV mount or to the side, and still be covered by the TV. The trim ring's outside dimensions are 17.50" W × 18" H. Locate the panel close to a 110VAC source for amplifier or security panel power requirements — there's an outlet knockout in the bottom of the panel for installing a UL and/or ETL approved outlet or J-Box.

    Note: Have a licensed electrician install the outlet to meet current code requirements. There is no fire rating on this panel, so it should not be installed in fire-rated walls.

    2. Mounting the Enclosure

    • New construction flush mounting: mount the enclosure on a stud using two (2) metal wood screws.
    • Old work flush mounting: mount to the front of the studs using two (2) metal wood screws, or break the tabs off and use four (4) metal wood screws to attach the enclosure to the inside of the studs.

    3. Cabling Rough-In and Mounting Brackets

    Install appropriate cables from each location, leaving enough overage on each end for easy installation, and mark all cable ends with necessary information. Each cable run should comply with all applicable codes; follow good wiring practices throughout. Secure the mounting brackets to the back of the enclosure using the included six (6) bracket mounting screws. If access to the USB ports on the TV power supply is needed, remove the large knock-out above or below the mounting brackets.

    4. Duplex Receptacle Knock-Out (Sold Separately)

    1. Remove the receptacle knock-out in the bottom of the panel.
    2. Install a UL and/or ETL approved receptacle box.
    3. Run proper wires to the receptacle box, per code.
    4. Install a UL and/or ETL approved receptacle rated 125 VAC.
    5. Install the receptacle cover.
    6. Ensure that all electrical work is done by a licensed electrical contractor.

    5. Install Trim Ring

    If the TV will not be installed flush against the wall, complete the installation by placing the trim ring onto the Connected Media Box, aligning the grooves on the sides with the slots on the box, then securing it with the included four (4) screws. Use caution not to over-tighten — this may deform the trim ring. If the TV will be mounted directly against the wall, do not install the trim ring.

    Safety Warnings

    • Never install low voltage wiring during lightning storms.
    • Never install low voltage wiring in wet locations unless the wire is specifically designed for wet locations.
    • Never touch un-insulated low voltage wires or terminals unless the wire has been disconnected at its source.
    • Do not use this product near water (bath tub, wash bowl, kitchen sink, laundry tub, wet basement, or swimming pool).
    • Consult and comply with local building and electrical codes before and during installation of any equipment.
    • Never push objects of any kind into this product through cabinet slots — they may touch dangerous voltages.
    • Use caution when installing low voltage cables.
    • Read and understand all instructions, and save them for future reference.

    Note: The Connected Media Box is a distribution panel for low voltage wiring systems only — it is not designed for use as an AC power distribution panel. Use only Class 2 powered or passive devices.

    Certifications

    ETL Listed. Conforms to UL STD 2416, ANSI/UL STD 60950-1. Certified to CAN/CSA STD C22.2 No. 60950-1.

    Manufacturer Contact

    DataComm Electronics, Inc., 6349 Peachtree Street, Norcross, GA 30071-1725. Phone: 888.223.7977 or 770.662.8205. www.DataCommElectronics.com