September 08, 2026 5 min read
Installation and programming guide for the Voice Alert wireless talking alarm base and motion detector/transmitter.
Note: The source manual for this model is published in French only (Comod'Alarm / Voice Alert™). The summary below is translated for reference; refer to the downloadable original for the manufacturer's exact wording.
The Voice Alert™ Talking Alarm (models VA-6000S base + VA-6000T detector/transmitter) is a wireless motion-detection alert system. The infrared motion detector/transmitter (VA-6000T) has a battery-powered range of roughly 300 meters (line of sight) and triggers the VA-6000S receiver base, which plays back up to 6 pre-recorded voice messages in the user's own voice. An unlimited number of detectors/transmitters can be installed, and the base includes 4 dry-contact (open/closed) outputs for triggering other devices such as lighting or additional transmitters.
Typical uses: entry/driveway/pool/garage monitoring, wander/elopement alerts, and custom deterrent messages.
Remove the VA-6000T cover by pressing the release tab underneath, then connect a 9-volt alkaline battery.
Use the included AC adapter/charger (220V/50Hz) and plug it into the back of the VA-6000S base.
Slide to "RECORD", hold the PLAYBACK button, and speak a message (e.g. "Change battery") into the MIC, then return to "RUN". Press button #1 for 2 seconds to hear this alert. When a VA-6000T's battery needs replacing, the base's LOW BATTERY LED flashes and the base plays the low-battery message together with the affected detector's normal message, helping you identify which unit needs a new battery.
When a message plays, the "MSG" LED flashes to indicate an alert occurred while you were away. Press PLAYBACK to hear the corresponding message(s); the LED turns off once playback finishes.
Each VA-6000T ships pre-programmed and works out of the box. To change its code or add additional detectors:
Note: Multiple detectors set to the same dip-switch code will all play the same message.
Switch W1 on the detector disables the red indicator LED (set to OFF to save power). Dial VR1 sets the delay between transmissions (up to 3 minutes) to avoid cascading alerts on repeated detections — factory default is zero delay. For maximum power savings, set W1 to OFF and VR1 to its longest delay.
Factory coverage pattern covers a 12 m × 12 m area when mounted at 2.30 m height. Interchangeable lens masks/caps let you narrow the field to a vertical or horizontal pattern as needed. To change: remove the cover, insert the chosen mask into the frame behind the lens, and press it gently into place. Always verify coverage with test walk-throughs after adjusting.
Each VA-6000T ships pre-programmed to work with any VA-6000S base within range. To dedicate a transmitter to a specific base, or simply change its code: remove the cover and set the dip-switches to a different combination than your current transmitter, then re-teach the new code to the base (see Programming section above). Detectors sharing the same dip-switch code will all trigger the same message, so the base doesn't need to be reprogrammed for each additional unit sharing that code.
The VA-6000T can operate as a transmitter only (motion sensing disabled) by setting the ON/OFF switch to OFF and wiring any external wired sensor of your choice to the screw terminal block.
Up to 4 dry-contact (0V, no-voltage) devices can be connected to the base's rear outputs, rated up to 24VDC / 1A. Terminals NO.1–NO.4 correspond to channels #1–#4. To set contact duration (no output, 1 sec, 5 sec, 30 sec, 60 sec, or continuous):
Note: If set to "CONTINUOUS" and triggered, toggle the power switch OFF then ON to reset the contact.
Recorded messages can be routed to an intercom or PA system via the base's "LINE OUT" jack (in the same row as the other contact outputs). Volume for this external output is controlled on the connected intercom/amplifier, not on the base's own VOLUME knob.
Voice Alert carries a 1-year legal warranty.
| Problem | Check |
|---|---|
| No sound | Power switch is ON; selector is on "RUN"; VOLUME isn't at minimum; outlet/power supply is good; at least one message is recorded; test each message button; confirm at least one detector/transmitter is active |
| Detector/transmitter not working | Check the 9V battery; confirm base is plugged in; re-verify installation and programming steps (especially that SETUP LED blinked during programming, step 3) |
| Weak radio range | Check detector battery; check base's AC adapter; compare against another detector; keep away from metal masses; try relocating the detector 30–50 cm |
| Messages won't record properly | Confirm base is plugged in; increase recording volume; make sure selector is on "RECORD" |
| Message doesn't play on PLAYBACK | Increase volume; confirm selector is on "RUN"; press the correct message button (#1–#6); confirm base is plugged in |
| Low playback volume | Increase volume to max; confirm base is plugged in; re-record message speaking closer/louder into mic |
| Distorted playback | Reduce volume; re-record with mouth slightly farther from mic; confirm base is plugged in |
| Messages (#1–#6) don't play back | Confirm selector is on "RUN"; confirm base is plugged in |
| Detector battery drains quickly | Enable power-save settings (W1 and VR1 — see Power-Save Mode); replace battery |