August 31, 2026 6 min read
Complete instruction guide for the LifeSource® Deluxe One Touch Digital Wrist Blood Pressure Monitor, Model UB-521 (A&D Medical).
Complete instruction guide for the LifeSource® Deluxe One Touch Digital Wrist Blood Pressure Monitor, Model UB-521 (A&D Medical).
The UB-521 is intended for home use by adults 18+ to monitor blood pressure (systolic/diastolic) and pulse rate. It provides accurate readings on wrists with a circumference between 5.3" and 8.5" (13.5–21.5 cm).
The unit requires 2 "AAA" (1.5V) alkaline batteries (included) — rechargeable batteries will not work.
Wait 5–10 minutes between measurements to let blood flow return to normal. Poor circulation (especially cold hands/wrists in winter) may prevent a reading.
| Condition | Recommended Action |
|---|---|
| Measurement in progress (blinks while detecting pulse) | Remain as still as possible |
| Irregular heartbeat or body movement detected | Take the measurement again and consult your physician |
| Battery low (blinks) | Replace all batteries with new alkaline batteries |
| Unstable blood pressure due to excessive body movement | Remain very still and try again |
| Systolic/diastolic values within 10 mmHg of each other | Fasten the cuff correctly and retry |
| Pressure value did not increase during inflation | Check for air leaks along the tube and air socket |
| Cuff not fastened correctly | Refasten the cuff and retake measurement |
| Air leak in cuff or monitor | Make sure the tube is properly connected |
| Pulse not detected correctly | Remain very still and try again |
The UB-521 still provides a blood pressure and pulse reading even if an irregular heartbeat occurs (defined as a heartbeat varying by 25% from the average of all heartbeat intervals during measurement). The Irregular Heartbeat symbol will display when this happens. Relax, remain still, and don't talk during measurement; contact your physician if you see this symbol frequently.
The Cuff Inflation Meter (left side of the display) moves up during inflation, starting at 20mmHg. The UB-521 also displays an average blood pressure reading based on all measurements stored in memory, along with the number of measurements, both when taking a new reading and when recalling stored measurements.
Provides a quick visual snapshot of your blood pressure classification per the Seventh Report of the Joint National Committee (JNC7) on Prevention, Evaluation and Treatment of High Blood Pressure (National Heart, Lung and Blood Institute, May 2003). This is approximate — other risk factors (diabetes, obesity, smoking, etc.) affect interpretation, so consult your physician. Residents outside the U.S. (Canada, Mexico) should reference the WHO Classification Table below.
Stores up to 90 blood pressure and pulse measurements, indexed from newest to oldest (oldest = "n01"). To retrieve: with the display blank, press and hold START — the average reading displays first, then the memory index number (e.g. "n04") of the most recent reading followed by its measurement; release START when you see the index number. The display shuts off automatically a few seconds after all readings display. If no measurements are stored, you'll see "00" and a blinking "A00". To clear all memory, remove and reinsert the battery. Note: memory is lost if batteries go low or are removed.
Blood pressure is the force exerted by blood against artery walls — systolic occurs when the heart contracts, diastolic when it expands, measured in mmHg. It's affected by age, weight, time of day, activity, climate, altitude, season, caffeine/alcohol, medications, stress, and even tight clothing. Blood pressure normally rises during activity and falls to its lowest during sleep.
| Classification | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|
| Normal | < 120 | and < 80 |
| Prehypertension | 120–139 | or 80–89 |
| Stage 1 Hypertension | 140–159 | or 90–99 |
| Stage 2 Hypertension | ≥ 160 | or ≥ 100 |
| Classification | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|
| Optimal | < 120 | and < 80 |
| Normal | < 130 | or < 85 |
| High-Normal | 130–139 | or 85–89 |
| Stage 1 Hypertension | 140–159 | or 90–99 |
| Stage 2 Hypertension | 160–179 | or 100–109 |
| Stage 3 Hypertension | ≥ 180 | or ≥ 110 |
Readings in a doctor's office or hospital can be elevated by anxiety ("white coat hypertension"). Home self-measurement supplements your doctor's readings and provides a more complete blood pressure history; studies show detection and treatment of hypertension improves when patients both consult their physician and monitor at home. Different cuff sizes used by different providers can also cause reading differences — a too-large cuff reads low, a too-small cuff reads high.
Readings are recorded as systolic/diastolic (e.g., 120/80) with pulse noted separately (e.g., "P 72"). Additional resources, large-print manuals, and logbook sheets are available at www.LifeSourceOnline.com.
| Problem | Cause / Action |
|---|---|
| Nothing appears in the display | Batteries drained (replace) or terminals reversed (reinstall correctly) |
| Cuff does not inflate | Battery voltage too low — replace all batteries |
| Unit does not measure | Cuff not fastened properly — refasten correctly |
| Readings too high or low | You moved during measurement, or cuff position is wrong — sit still with the cuff at heart level |
| Value differs from clinic reading | Different cuff size used by clinician, or "white coat hypertension" |
If these steps don't resolve the issue, call 1-888-726-9966. Do not attempt to repair the device yourself.
| Model | UB-521 |
| Type | Oscillometric |
| Display | Digital, 9/7-mm character height; pressure & pulse shown simultaneously |
| Memory | 90 readings |
| Measurement range | Pressure: 20–280 mmHg; Pulse: 40–180 pulses/min |
| Accuracy | Pressure: ±3 mmHg or ±2% (whichever greater); Pulse: ±5% |
| Pressurization / Deflation | Automatic micropump inflation; automatic solenoid valve deflation |
| Power source | 2x AAA (1.5V) alkaline batteries (included) |
| Battery life | Approximately 400 measurements |
| Operating environment | 50°F–104°F (10°C–40°C), <95% relative humidity |
| Storage environment | 14°F–140°F (-10°C–60°C), <95% relative humidity |
| Wrist circumference range | 5.3"–8.5" (13.5–21.5 cm) |
| Dimensions | 1.2" L x 2.4" W x 2.6" H (30 x 60 x 65 mm) |
| Weight | 3.2 oz (89g) without batteries |
Measurements are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by ANSI for electronic/automated sphygmomanometers.
Covered by a Lifetime Warranty (see warranty card for details); register at www.LifeSourceOnline.com. A&D Medical, a division of A&D Engineering, Inc., 1756 Automation Parkway, San Jose, CA 95131. LifeSource Health Line (toll-free): 1-888-726-9966. www.LifeSourceOnline.com