August 31, 2026 7 min read
Complete installation and programming manual for the 2GIG-CP2 Go!Control wireless security system control panel.
Full installation and programming manual for the 2GIG-CP2 Go!Control wireless security system control panel — covers system overview, sensor/accessory catalog, wiring, installer programming, sensor types, testing, and warranty.
The Go!Control Security System is a fully supervised wireless security system with a color touch screen Control Panel that can be expanded and customized. It's designed to meet or exceed ETL Listed residential security requirements and conforms to the Security Industry Association's Control Panel Standard ANSI/SIA CP-01-2007.
Note: Failure to install per ETL requirements voids the ETL listing. For an ETL smoke alarm system, at least one approved smoke detector must be programmed into the Control Panel to meet NFPA Rule 72-Chapter 2 and UL 217 requirements — many insurers require this for a discount. Some municipalities require an alarm system permit — check local authorities before installing.
The Control Panel's color touch screen controls all system functions and programming, with scrolling text and voice prompts. The system supports 48 wireless sensors of various types, two hardwire loops, 15 sensor response types, a supervised bell output, and a programmable solid-state control output. An on-board digital communicator reports alarms/trouble to a central monitoring station via standard telephone line.
An internal 345 MHz narrow-band radio receiver detects wireless sensor signals. The optional Model 2GIG-XCVR2 900 MHz transceiver enables communication with accessory wireless touch screen keypads. The optional Model 2GIG-GSMx GSM radio modem adds wireless Central Station reporting and 2-way voice communication "over-the-air," plus 2-way communication with the Alarm.com server (subscribers can query/control the system from a browser anywhere; the server can send messages, time corrections, and software updates). A built-in Z-Wave radio module allows controlling/monitoring home automation devices (lighting, locks, heating, A/C).
Eight user codes (including a duress code) are supported; User 1 is the master code that can add/delete the other seven. The Installer Code has access to system programming. Front panel buttons double as emergency indicators for Panic, Fire, and Emergency alarm activation (each individually enable/disable-able and programmable).
Install each wireless sensor at its desired location per the instructions included with the sensor, and document each sensor's ID number and location in the Installation Log.
Hardwired loops can be programmed normally open (N/O) or normally closed (N/C), with optional 2.2K ohm end-of-line resistors (EOLR, not supplied) for supervision. Only contacts should be used — the Control Panel does not power external devices like PIRs. Hardwired loops cannot be used for a CO or fire sensor loop.
Two terminals support an optional remote electronic (solid-state) sounder — do not connect an electromechanical bell. The bell output can be supervised for wire-cut detection (bell trouble reporting).
One programmable solid-state output switches up to 250 mA @ 16 VDC to ground, active during various programmable conditions. It only functions while the Control Panel has wall power. Warning: do not connect an electromechanical bell to this output — it will damage the output. For ETL Listing, an external DC backup power supply is required for a load connected to terminal 4.
Both incoming and outgoing telephone lines connect to the Control Panel via an RJ31X jack. When the communicator activates, local telephones are disconnected to prevent an off-hook phone from blocking the call. Run a 4-conductor cable from the demarcation box, disconnect house telephones from the box output (without disturbing the Telco input "drop" side or earth grounds), wire RED/GREEN to the box RING/TIP, and BLACK/YELLOW to the house telephone RING/TIP wires. At the panel, connect RED→RING IN, GREEN→TIP IN, BLACK→RING OUT, YELLOW→TIP OUT on the RJ31X jack.
| 1 | 14VDC Power Input (+) — only provides DC power when the panel's power supply is connected to AC |
| 2 | 14VDC Power Input (-) |
| 3 | Ground |
| 4 | Open Collector Output — 250mA @ 16VDC maximum |
| 5 / 6 | Bell (+) / Bell (-) — supervised bell output, 6-12VDC @ 120mA max |
| 7 / 8 | Hardwire Loop 1 / Hardwire Loop 2 |
All output voltages are Class 2. Hardwire loops can use normally open or normally closed contacts, with optional 2.2K EOLR for N.C., N.O., or mixed EOL loop supervision configurations.
The Installer Toolbox (default Installer Code = 1561) provides access to RF Sensor Programming, Wired Sensor Programming, RF Key Fob Programming, RF Keypad Programming, and the full set of Control Panel Programming Questions (Q-1 through Q-86+), covering exit/entry delays, dialer/Central Station settings, 2-way voice, emergency key types, quick arming, swinger shutdown, siren supervision, daylight saving settings, Z-Wave feature enable/disable (switches, thermostats, door locks), temperature display units, and more.
| Type | Behavior |
|---|---|
| (00) Unused | No system action from this sensor number. |
| (01) Exit/Entry 1 | For exit/entry doors; starts Exit Delay when arming (Away or Stay), starts Entry Delay #1 when triggered while armed. |
| (02) Exit/Entry 2 | Same as Exit/Entry 1 but starts the (typically longer) Entry Delay #2 timer — e.g. for a garage door. |
| (03) Perimeter | Instant alarm when triggered while armed (Stay or Away) — not used for entry/exit. |
| (04) Interior Follower | Instant alarm in Away Mode once armed (after Exit Delay); always bypassed in Stay Mode. |
| (05) Day Zone | Same as Perimeter, but shows a trouble alert (not an alarm) when violated while disarmed. |
| (06) 24-hour Silent Alarm | Always active; sends silent panic code to Central Station with no local indication. |
| (07) 24-hour Audible Alarm | Always active; triggers local alarm and bell output regardless of arming mode. |
| (08) 24-hour Auxiliary Alarm | Always active; triggers alarm (no bell) — local sounder continues until acknowledged. For flood/temperature monitoring. |
| (09) 24-hour Fire † | Always active, cannot be bypassed; triggers fire sounder and bell. For wireless smoke detectors. |
| (10) Interior with Delay | Delayed (Entry Delay #1) in Away Mode; instant if armed-instant; bypassed in Stay Mode. |
| (14) 24-hour Carbon Monoxide † | Always active, cannot be bypassed; triggers pulse sounder and bell. For wireless CO detectors. |
| (16) 24-hour Fire with Verification † | Always active, cannot be bypassed; requires two violations in two minutes (or 30 sec continuous) to confirm fire. |
| (23) No Response Type | Special zone monitored by Central Station for activity/inactivity; doesn't affect security status. |
| (24) Silent Burglary | Instant silent alarm when triggered while armed; no local sounder or bell. |
† Not allowed for hardwired loops.
From the Installer Toolbox, press DISABLE SOUNDER to lower the internal sounder and disable the external siren for 30 minutes during testing (auto re-enables after timeout, or manually via ENABLE SOUNDER).
Inform the Central Station that test signals will be sent, then trigger each alarm type in sequence (24-hour fire/FIRE button, 24-hour panic/PANIC button, 24-hour emergency/EMERGENCY button, and an armed burglary sensor), waiting ~45 seconds between each for the report, then disarming. Confirm with the Central Station that each zone type was received.
Tests all sensors, indicators, and the sounder; auto-ends after 25 minutes. Enter via the Installer Toolbox > WALK TEST. Activating each sensor sounds three beeps and lights a green bar (1-5 bars = signal strength) next to the sensor's name on the display; a check mark confirms sufficient signal. Weak-signal sensors may need relocating. Entering/exiting Walk Test sends "start test"/"stop test" reports to the Central Station.
If a GSM module is installed, the Radio Status screen shows signal strength, serial number, and registration status (color-coded: red = weak/unregistered, orange = idle/registered, green = good signal/registered). RUN RADIO TEST checks the cell connection to the Central Station. A separate Telephone Test (User Toolbox #3, requires Master User Code) checks the landline connection via the built-in digital communicator.
A soft reset via the Installer Toolbox's Restore Defaults screen lets you selectively reset ZONES (erases all 48 sensors' data) and/or other settings via checkboxes. A "hard" reset to out-of-box factory defaults is also available by pressing and holding the Emergency and Home buttons while applying power (unless disabled via programming questions Q-44/Q-45).
Complies with FCC Part 15 rules and FCC telephone rules/regulations (limits on auto-dial retries, ringer equivalence). This security system complies with NFPA requirements for temporal pulse sounding of fire notification appliances. See the manual's Limited Warranty section for full terms; 2GIG Technologies Inc. products are covered against defects in materials/workmanship, with the standard exclusions for consequential damages and implied-warranty duration limits.