  • Zipato MicroModule Switch Double (PAN04) — Installation Guide

    September 08, 2026 3 min read

    Quick installation guide for the Zipato MicroModule Switch Double (PAN04), a Z-Wave in-wall dual-relay switch with power metering and overload protection.

    Full text manual (for reference)

    Quick installation guide for the Zipato MicroModule Switch Double (PAN04) — an in-wall Z-Wave micromodule with two relays for controlling AC power (light switching), with power/energy metering and overload protection.

    Introduction

    The MicroModule Switch Double is a Z-Wave™-enabled transceiver, fully compatible with any Z-Wave network. Its mini-size design lets it hide inside a standard wall box, keeping the room's decor clean — no visible module. A common application is light control: switching AC power ON and OFF to a load, most often lighting.

    The module's smart relay calibration technology reduces the inrush current caused by the connected load, letting it work reliably with incandescent, fluorescent, and LED lighting.

    Power Metering & Overload Protection

    The module detects instant power wattage (5–1500W) and overload wattage (1600–1700W) of the connected light or appliance. When it detects an overload condition, the module disables itself and its ON/OFF button is locked out, with the LED flashing quickly for 30 seconds. Unplugging and reconnecting the module resets the overload condition back to normal.

    The module can proactively report instant power wattage when it varies by more than 5%, or report a state change using the S1/S2 inputs — this lets the controller avoid polling for wattage and state, improving overall controller efficiency.

    Features

    • Z-Wave protocol for secure two-way wireless communication
    • Newest Z-Wave 400 series chip, multichannel operation, higher data rate (9.6/40/100 kbps)
    • Higher RF output power (+2.5 dBm vs. −2.5 dBm on 300 series Z-Wave modules) for enhanced communication range
    • Zero-crossing technology extends the number of switching cycles
    • Slim design for easy installation
    • Resistive load rating: 1500W × 2
    • Instant power wattage and accumulated power consumption (kWh) reporting
    • Overload protection with automatic disable/lockout
    • Auto-report of state on manual ON/OFF button press
    • Auto-report of wattage when variation exceeds 5%
    • Z-Wave V6.02; very low standby electricity consumption, meeting EU energy-related products directive 2009/125/EC no. 1275/2008

    Wiring & Terminals

    Terminal layout: NEUTRAL, LIVE, NO1, NO2 (relay outputs), plus S1 and S2 input terminals for external switch inputs. Application example: In-wall switch, 2-relay, 1A type — L (line) and N (neutral) feed the module; S1/S2 connect to external switches; NO1/NO2 (relay 1/relay 2 outputs) feed Load 1 and Load 2 respectively.

    Specifications

    Category Spec
    No Load Standby Power 0.48W (230V) / 0.35W (120V)
    Input Voltage 90–240 VAC, or 24–60V DC ±10% (DC mode disables the metering function)
    RF Frequency PAN04-1: 868.42 MHz (EU) · PAN04-2: 908.42 MHz (USA/Canada) · PAN04-3: 922.5/923.9/926.3 MHz (Taiwan/JP)
    Regulation FCC Part 15.249 / EN300 220-1 / NCC
    RF Distance Min. 40m indoor / min. 100m outdoor
    Weight / Dimensions 30g / 47.5 × 39 × 15.6 mm
    Operating Temperature / Humidity 0–40°C / 85% RH max
    Load (Resistive / Overload) 1500W × 2 (230V), 800W × 2 (120V) resistive / 1650W (220V), 880W (120V) overload threshold
    Load Return Error Rate ±3W for 5–40W loads; ±5% for 40–1500W loads
    Compliance Z-Wave Certificate No. ZC08-13040018; LVD EN 60669-2-1/-2-2/-1; R&TTE EN 301489, EN 300200

    Safety Warnings

    • All work on the device should only be carried out by trained and skilled electricians, observing country-specific regulations.
    • Risk of electrocution / fatal injury from electric current. The device has no basic insulation and must be installed in a way that protects against accidental contact.
    • Connected devices and the flush-mounted receiver can be damaged if operated outside their technical specifications.
    • When installing a wall plate, maintain at least 4mm of clearance between the cover's fixing brackets/screws and the flush-mounted module's connections — use a deeper installation box if this clearance can't be met. Only insulated tools (e.g. an insulated phase tester) should be used when working on the device.

    Warranty

    One (1) year limited product warranty from Tri plus grupa d.o.o. (Zipato), covering defects in materials and workmanship under normal use, per the terms in the full manual. Contact: +385 1 4004 404, www.zipato.com.