August 31, 2026 5 min read
Installation and programming instructions for the Yale Real Living Push Button Lever (YRL210ZWx) — mounting, PIN code programming, factory settings, and troubleshooting.
Installation and programming instructions for the Yale Real Living™ Push Button Lever (YRL210ZWx series) — a keyless push-button entry lever lock with PIN code management and optional Z-Wave network module.
⚠ Follow these instructions carefully — improper installation can damage the product and void the factory warranty.
Tools needed: #2 Phillips screwdriver. Through-bolt post length is 2-3/8" by default, or 2-3/4" optional depending on door backset.
Door handing is determined from the secure side of the door (the side from which you initially unlock and enter):
After installation, continue with the Programming Instructions to set up the Master PIN code and customize the lock.
Warning: resetting deletes all user codes (including the Master PIN) and restores all default settings.
After a reset, creating the Master PIN Code is the only available option and must be done before any other programming.
Max user codes: 250 with the Network Module installed, or 25 without. The Master PIN Code must be created before any further programming.
Follow the keypad prompts and enter a 4–8 digit PIN when prompted, confirming with the check-mark key.
The Master PIN must exist first. Enter the Master PIN, follow the keypad prompts, select a user number (1–25 or 1–250 with Network Module), then enter a 4–8 digit PIN code for that user.
Enter the PIN code, then press "Unlock."
| Setting | Factory Default |
|---|---|
| Master PIN Code | Registration required |
| Automatic Re-lock | Disabled |
| Inside Indicator Light | Disabled (Off) |
| One Touch Locking | Enabled |
| Volume Setting | Enabled (Low) |
| Automatic Re-lock Time | 30 seconds |
| Wrong Code Entry Limit | 5 times |
| Shutdown Time | 60 seconds |
Enter the 4–8 digit Master PIN followed by the M key, then enter the digit for the function to perform, followed by the M key. Options include: Master PIN Code Setting, User PIN Code Registration (register/delete, user numbers 1–25 without Network Module or 1–250 with it), Advanced Lock Settings (Automatic Re-lock enable/disable, One Touch Locking enable/disable, Handing the Lock — automatic), Audio Mode (enable/disable — select Disable for quiet areas), All Code Lockout Mode (enable/disable), and Network Setting (join/exit network).
Replacing the cylinder: follow Step 6 (Installing Exterior Lever) in reverse to remove the old cylinder, then follow the same step to install the new one. Test with "Testing Operation" afterward.
| Symptom | Suggested Action |
|---|---|
| Lock does not respond, door open/accessible | Test each keypad button; check battery orientation/condition; replace if discharged. |
| Lock does not respond, door locked/inaccessible | Use the key to gain entry and replace batteries. |
| Chimes to confirm code but door won't open | Check for another locking device or foreign objects in the door gap. |
| Allows access but won't auto re-lock | Check cable connection to PC board; confirm Auto Re-lock is enabled; replace batteries if low-battery indicator is lit. |
| PIN codes will not register | Must be 4-8 digits, unique per user, entered within 5 seconds; no * or # in the code; contact the Master user if registration authority is needed. |
| Beeps + red/blue flashing 7x, won't unlock | All Code Lockout Mode is enabled — only the Master user can disable it. |
| No sound during operation | Enable Audio Mode. |
| Intermittent red flashes | Low battery — replace all 4 AA alkaline batteries. |
| Beeps + keypad flashes 3x after PIN entry | Digits entered were incorrect/incomplete — re-enter and confirm with the check-mark key. |
Note: Network-connected locks have a real-time clock reset upon battery replacement — verify correct date/time, especially around Daylight Saving Time changes.
Class B digital device, compliant with FCC Part 15. Meets Canadian Interference Causing Equipment Regulations. Modifications not expressly approved by Yale Security Inc. could void the user's authority to operate the equipment.
Manufacturer: Yale Security Inc., an ASSA ABLOY Group company · Product Support: 800-810-WIRE (9473) · www.yalelocks.com