    August 31, 2026 4 min read

    Installation and programming instructions for the Yale Assure Lock Electronic Interconnected Touchscreen deadbolt, models YRC226, YRC426, and YRC620.

    Full text manual (for reference)

    Installation and programming instructions for the Yale Assure Lock Electronic Interconnected Touchscreen — models YRC226, YRC426, and YRC620. Available with a 4" or 5.5" touchscreen, and optional Network Module (Z-Wave Plus, ZigBee, iM1, or Bluetooth) — not available on YRC620.

    Before you begin: Download the BILT App for step-by-step installation instructions and product registration. Retrofitting or modifying this product may impact fire rating, safety features, and warranty — consult local code specifications for compliance.

    Installation Overview

    Full illustrated installation is a multi-step door-preparation process covered in detail in the downloadable PDF (marking reference lines, drilling holes, installing strike plates, determining handing, mounting the lock body and touchscreen). General steps:

    1. Mark door reference lines using the included template and existing backset (2-3/8" or 2-3/4").
    2. Drill mounting holes — drill halfway through the door from each side to prevent splitting.
    3. Install strike plates (1" dia. holes at specified depths).
    4. Determine door handing before mounting the lock body.
    5. Install the exterior lock body, then the interior touchscreen assembly, routing the wire harness cleanly through the hook on the mounting plate.
    6. Install batteries and battery cover.

    Factory Settings (Out of the Box)

    Setting Factory Default
    Master PIN Code Registration required*
    Automatic Re-lock Disabled
    Inside Indicator Light Disabled (Off)
    One Touch Locking Enabled
    Privacy Button Setting Disabled
    Volume Setting Enabled (Low)
    Language Setting English
    Lockout Mode Disabled
    Wrong Code Entry Limit 5 attempts
    Shutdown Time 60 seconds

    *The Master PIN code must be registered before any other programming can be performed.

    Programming — Creating the Master PIN Code

    Required immediately after installation or after a factory reset — nothing else can be programmed until this is done.

    1. Touch the screen with the back of your hand or palm to activate it. Lock responds: "Register Master Code. Press the gear key to continue."
    2. Press the gear key.
    3. Enter a 4–8 digit Master PIN code, then press the gear key again to confirm ("Entered").

    Creating User PIN Codes

    Maximum user codes: 250 with a Z-Wave Plus or ZigBee network module; 25 without a network module or with the iM1 module; 12 with Bluetooth.

    1. Enter the Master PIN code, press the gear key — lock enters Menu Mode.
    2. Select the User PIN Code Registration menu option, then "Register."
    3. Enter a 4–8 digit PIN code (it will flash), press the gear key.
    4. To add more user codes, repeat; to finish programming, select "End."

    Menu Mode — Feature Programming (YRC226)

    Enter the Master PIN code + gear key to reach Menu Mode, then select a menu number:

    • 1 — Master PIN Code Setting
    • 2 — User PIN Code Registration (Register / Delete)
    • 3 — Advanced Lock Settings: Automatic Re-lock (Disable / 30 sec / 60 sec / 2 min / 3 min), Inside Indicator Light (Enable/Disable), One Touch Locking, Privacy Setting Mode, Handing the Lock (automatic), Volume (High/Low/Silent), Language (English/Spanish/French), Lockout Mode
    • Network Module Setting (only shown if a network module is installed): Join the Network / Exit the Network

    Menu Mode — Feature Programming (YRC620)

    Same basic flow as YRC226, with these additions: Automatic Re-lock time is settable from 1–180 seconds; adds an Escape Return Mode option (note: if enabled, Automatic Re-lock cannot also be enabled); adds Set Up SEOS Card for credential-based access.

    Key Definitions

    • All Code Lockout Mode: Enabled via the Master code — restricts all user (non-Master) PIN access. A red locked padlock icon appears on screen when active.
    • Automatic Re-lock Time: After a successful unlock, the door re-locks automatically after the selected duration (Advanced Lock Settings, menu #3).
    • Handing the Lock: Refers to which direction the bolt extends (right/left) — the lock can auto-detect this or be manually re-handed via Hardware Troubleshooting steps.
    • Low Battery: Low Battery Warning indicator flashes RED. If power is fully lost, use the cylinder key override.
    • Master PIN Code: Used for programming and settings; also operates lock/unlock. Must be registered before any other programming.
    • One Touch Locking: When latch is retracted, any keypad activation extends the latch (respecting Auto Re-lock timing).
    • Privacy Mode: Press and hold the privacy button 4 seconds to enter do-not-disturb mode — disables all PIN codes. Disabled by default.
    • Shutdown Time: After 5 failed PIN attempts, the unit shuts down (flashing RED) and won't respond for 60 seconds.
    • Tamper Alert: Audible alarm if the outside lock is forcibly removed from the door.

    Resetting to Factory Default

    Warning: This deletes ALL user codes, including the Master PIN code, and resets all programming to defaults.

    1. Remove the battery cover and batteries.
    2. Remove the interior lock to access the reset button hole.
    3. Re-insert 3 batteries; insert a small screwdriver into the reset hole and hold the button for 3 seconds.
    4. While still holding the button, insert the 4th battery and continue holding for 3 more seconds.
    5. Release the reset button, then re-install the interior lock onto the door.

    After a reset, creating a new Master PIN Code is the only available option and must be done before any other programming. For best results, perform the reset with the lock installed on the door.

    Hardware Troubleshooting

    Symptom Fix
    Bolt won't extend, motor grinding Enter Master PIN, press Menu Option 3 (Advanced Lock Settings), press Option 5 to re-hand the lock, then test locking via keypad.
    Door is binding Check door/frame alignment and that the door swings freely; check hinges for looseness or wear.
    Bolt won't deadlock Check for sufficient bolt clearance in the strike-side jamb (deepen the pocket if needed); check bolt/strike alignment with the door open.
    Bolt doesn't move smoothly Check bolt/strike alignment, backset, door prep hole sizing, wire harness routing, and that the bolt is installed with the correct side up.
    Keypad numerics scrolling Remove the interior escutcheon; check wire terminal connections and that the harness lies flat and isn't pinched.

    Replacing the Cylinder

    1. Remove the touchscreen from the door.
    2. Remove the pan head screw.
    3. Let the cylinder drop out of the assembly.