Instruction manual for the X10 UM506 Universal Module, a plug-in relay module for furnaces, lighting, garage doors, and more.
Instruction manual for the X10 UM506 Universal Module — a plug-in X10 receiver module with a single-pole relay for controlling furnaces (via low-voltage thermostat wires), low-voltage lighting, drapery controls, garage door openers, sprinkler systems, and more.
The UM506 receives X10 ON/OFF signals and closes/opens its internal single-pole relay switch accordingly. It plugs into a standard 120VAC outlet and receives commands over house wiring from any X10 controller — mini-controller, mini-timer, handheld wireless remote, wall controller, or PC interface. The internal relay is a path interrupter for devices not powered above 24VDC (5A) or 30VAC (3.3A).
| Spec | Value |
|---|---|
| Power requirement | 120VAC |
| Output rating | Max 24VDC/5A or 30VAC/100VA (3.3A) through the output terminals |
House Code Dial: letters A–P. Unit Number Dial: numbers 1–16. Each X10 receiver module is set to a unique unit number (or an identical unit number, if desired for group control). Each X10 controller operating a specific set of receiver modules must be set to the same house code as the receivers it controls.
Nearly all residential homes are wired split-phase, with each 120V phase not directly connected to the other. If an X10 receiver doesn't respond to a remote controller after installation, check that the breaker serving the receiver is on the same phase as the controller — if not, move it to the opposite phase, or install a phase coupler to improve remote communications throughout the home.
| Mode | Behavior |
|---|---|
| Momentary | On an X10 "ON" command, the relay closes for ~1.5 seconds then releases. |
| Continuous | On an X10 "ON" command, the relay closes and stays closed until an "OFF" command is received. The relay does not change status due to a power loss. |
| Sounder Only | A sounder activates; no relay switching occurs. |
| Sounder & Relay | A sounder activates and relay switching occurs. |
| Relay Only | Only relay switching occurs. |
The UM506's output terminals can be directly wired to a PF284 PowerFlash Module's input terminals, letting an X10 ON/OFF command be sent to a detached facility on separate AC power via two low-voltage wires carrying minimal power:
In reverse, the PF284 senses a contact closure and sends an X10 ON command; the UM506, at a remote location on the same power system, receives it and emits a remote contact closure — useful for a detached garage security zone reporting a closure to an alarm panel.
120-day limited warranty from x10.com (a division of Authinx Inc.) against defective material and workmanship from the original date of retail purchase. X10 will repair or replace, at its discretion, a defective product returned within the warranty period with proof of purchase. Contact 1-888-384-0969, visit www.x10p.com, or email support@x10.com.