  • STI-34108 8-Channel Wireless Receiver — Installation and Operation Manual

    September 08, 2026 7 min read

    Installation and operation manual for the STI-34108 8-Channel Wireless Receiver, part of the STI Wireless Alert Series, covering DIP switch functions, zone enrollment, mirrored receiver systems, and keyfob operation.

    Full text manual (for reference)

    Installation and operation manual for the STI-34108 8-Channel Receiver, part of the Safety Technology International (STI) wireless Alert Series. This 433 MHz receiver monitors up to 8 different STI wireless sensor devices from a single, convenient location.

    How the Product Works

    The STI 8-Channel Receiver is a 433 MHz radio signal receiver that monitors up to 8 different STI devices. When placed in enroll mode, it lets you select one of 8 zones and enrolls a device once the receiver detects that device's wireless signal. STI's wireless system prevents accidental enrollment, alerts, or crosstalk from non-STI devices.

    Per zone, you can configure: a latching memory condition, siren activation, chime sounding, a normally open/closed switch trigger, or a 12VDC external output. The receiver can also act as a console repeater when paired with other 8-Channel Receivers, extending coverage to up to 4 additional areas over long distances or through disruptive terrain.

    Installation Guide

    Surface Installation

    1. Ensure mounting screws are removed.
    2. Insert provided rubber feet into holes on the bottom cover.
    3. Route wires under the product.

    Wall Mounted Installation

    1. Ensure rubber feet are removed.
    2. Remove the front cover screw.
    3. Remove the cover (be careful not to lose the push button).
    4. Mark mounting holes on the wall using the bottom cover as a template.
    5. Drill holes with a 3/16" drill bit.
    6. Insert provided wall anchors.
    7. Insert power cord and wires and route them on the back.
    8. Insert mounting screws into provided plastic washers.
    9. Insert mounting screws into PCB holes through the back of the cover.
    10. Insert mounting screws into wall anchors and tighten.
    11. Press-fit the push button onto the push button switch on the circuit board.
    12. Insert top cover tabs into bottom cover slots.
    13. Carefully close the top cover, ensuring the push button inserts into the cover hole and antennas rest in the side cover grooves.
    14. Insert and tighten the front cover screw.
    15. Plug in the AC adapter.

    DIP Switch Functions (Top Side)

    Switch Function ON (up) OFF (down)
    SW1 Master Receiver Setting (active only when SW8=ON) Enabled — set only if this is the Mirror Master Disabled — set off if not Mirror Master
    SW2 Enroll Devices Enabled — LED for zone waiting to enroll blinks; button changes zone Normal operation
    SW3 Alarm Latching (active only while sensor is being enrolled) LED turns on when triggered; button press turns off siren; LED flashes when restored LED turns on when triggered, off when restored
    SW4 & SW5 Receiver # / Siren Time When SW8=ON: sets Mirror # (00=#1, 10=#2, 01=#3, 11=#4) When SW8=OFF: sets Siren Time (00=Silent, 10=30 sec, 01=180 sec, 11=Continuous)
    SW6 Receiver Chime Chime sounds double-beep on trigger Chime does not sound
    SW7 Delete Devices All LEDs turn red; LED blinks for zone to delete; hold 5 sec to delete, hold again to delete all Normal operation
    SW8 Mirror Mode Enables Mirror Mode and SW1; SW4/5 set Receiver # Disables Mirror Mode and SW1; SW4/5 set Alarm Time

    Other Controls

    • Push Button — Selects zone to enroll or delete, acknowledges latched alerts (resets LED to green), silences alarm.
    • Zone LEDs (1-8): Red = zone in alarm; Flashing red = zone latched (was in alarm, now restored); Amber = sensor trouble (battery/tamper); Green = zone normal; Off = zone not enrolled.
    • Sounder — Provides audio feedback for siren, chime/beeps, and enrollment/deletion actions.

    Component Descriptions (Bottom Side)

    • Adapter Plug Input — 12VDC, 500mA, center-positive (adapter provided)
    • Triggered Output Plug — 12VDC output, activates at 75mA for 3 seconds when any zone triggers
    • Form C Switch Outputs (Dry Contacts) — 30VDC, 1A resistive. N.O. closes to COM when alarm triggers; N.C. opens to COM when alarm triggers.
    • 12VDC Input (500mA) — Powers the receiver from an external 12VDC, 500mA source
    • 12VDC Output (300mA) — Active only while the onboard sounder is activated (siren or chime mode)

    Normal Operation

    The receiver listens for 433 MHz signals from enrolled STI sensors, providing feedback via LED color, onboard sounder, switched Form C output terminals, a 3-second 12VDC/75mA triggered output pulse, and 12VDC output terminals synced with the sounder.

    LED priority (highest to lowest): Red (alert) > Flashing Red (latched, non-triggered) > Amber (tamper alert, non-triggered) > Green (normal, non-triggered) > Off (not enrolled).

    Siren Mode (SW6 OFF): 4 KHz @ 90dB tone for the duration set by SW4/SW5. Chime/Beep Mode (SW6 ON) overrides siren mode with a double beep on alert.

    Low Battery / Tamper / Out-of-Range: If a sensor's battery is weak, a tamper signal is triggered, or the sensor is out of range for 12-24 hours, that zone's LED lights AMBER.

    Zone Enrolling & Deleting

    The receiver enrolls up to 8 devices into zones 1-8 (sensors, mirrored receivers, or keyfobs). In ENROLL mode (SW2 ON), occupied zone LEDs turn red; the next available zone flashes green. Press the push button to cycle to a different available zone.

    Zone Latching

    Latching indicates a zone alert was triggered and has since cleared — the LED flashes red until the push button is pressed to acknowledge, returning it to green. Latching is set per-zone at the time of enrollment via SW3.

    Enrolling Sensors into Zones

    1. Confirm the receiver is not in DELETE mode (SW7 OFF).
    2. Set desired latching (SW3 ON if latching is wanted).
    3. Enable ENROLL mode (SW2 ON).
    4. Confirm the correct zone is flashing green; note occupied (red) zones.
    5. Trigger an alert on the sensor and return it to normal.
    6. The receiver double-beeps and the zone LED turns solid red.
    7. Repeat for additional sensors.
    8. Exit ENROLL mode (SW2 OFF).

    Tip: When first enrolling, set latching ON and enroll the sensor near the receiver before mounting it at its final location. After mounting, trigger it again to confirm signal — a solid or flashing red LED confirms reception. If latching isn't ultimately desired, delete and re-enroll that zone with SW3 OFF.

    Keyfob Operation

    An STI keyfob can remotely control the receiver's LEDs, sounder, and outputs, and act as a CALL/MANUAL ALERT button. The receiver continues monitoring sensors even when turned off via keyfob.

    • ON/OFF buttons do not enroll into zones — they toggle all receiver outputs (equivalent to cycling the push button). Enroll via ENROLL mode (SW2 ON), press ON or OFF on the fob; receiver double-beeps. Up to 8 keyfob ON/OFF pairs can be enrolled — enrolling a 9th deletes the oldest.
    • LEFT/RIGHT buttons enroll into a zone like a sensor. LEFT = CALL/MANUAL ALERT, RIGHT = RESTORE.

    Mirrored Receiver Systems

    Mirrored receivers duplicate the master receiver's LED status, sounder, siren time, and 12VDC output activation for sensors enrolled on the master. Up to 4 mirrors can be chained per master, each up to 1000 ft apart (multiple independent systems can also be linked to a central office/location).

    Enrolling mirrors (sequential pairs — Master→Mirror1, Mirror1→Mirror2, etc.):

    1. Confirm receivers are not in DELETE mode (SW7 OFF).
    2. Set SW4/SW5 on each mirror to its mirror number (1-4).
    3. Set SW1 and SW8 ON on the master receiver; set SW8 ON on each mirror.
    4. Enable ENROLL mode (SW2 ON) on both receivers being paired.
    5. Press the push button on the "Column A" receiver — Column B receiver double-beeps.
    6. Press the push button on the "Column B" receiver — Column A receiver double-beeps.
    7. Disable ENROLL mode (SW2 OFF) on both.
    8. Press the push button on Column A — Column B's LEDs mirror the same configuration.

    All sensors are enrolled only to the master receiver; mirrors copy the master's output (except latch settings) sequentially through Receivers 1-4. Keyfobs must be separately enrolled into each master/mirror receiver where they'll be used.

    Deleting Zones

    Deleting Single Zones

    1. Enter DELETE mode (SW7 ON) — all enrolled zone LEDs turn red, first deletable zone flashes red.
    2. Press/release the push button to cycle to the desired zone.
    3. Press and hold the push button for 5 seconds — receiver beeps once, LED turns off.

    Deleting All Zones (including keyfobs/mirrors)

    1. Enter DELETE mode (SW7 ON).
    2. Hold the push button for 5 seconds — first zone deletes (single beep, LED off).
    3. Continue holding — remaining zones flash for 5 seconds, then delete (double beep, all LEDs off).

    Regulatory & Warranty

    Model 34108. FCC ID: TXL34108. IC: 6335A-34108. Class B digital device per FCC Part 15 — designed to limit residential interference; no guarantee against interference in a particular installation. Complies with applicable Industry Canada technical specifications. Intended for home/office use in EU and EFTA member states.

    For indoor use only — keep away from water and damp areas.

    Warranty: Safety Technology International warrants this product free of defects in material and workmanship for one (1) year from original purchase date. Electronic warranty form available at www.sti-usa.com/wc14.

    Related STI Wireless Alert Series Products

    • STI-34098 — Single Channel Slave Receiver
    • STI-V34104 — 4-Channel Voice Receiver
    • STI-34188 — 8-Zone Relay Board
    • STI-34101 — Solar Powered Driveway Monitor Sensor
    • STI-34151 — Battery Powered Driveway Monitor Sensor
    • STI-34201 — Wireless Mail Alert Sensor
    • STI-34301 — Wireless Garage Sentry Sensor
    • STI-34401 — Wireless Universal Alert Sensor
    • STI-34501 — Wireless Door Entry Alert Sensor
    • STI-34601 — Wireless Doorbell Button
    • STI-34701 / STI-34752 — Indoor / Outdoor Wireless PIR
    • STI-30105 — Extended Antenna
    • STI-34105 — Voltamax 12VDC (500mA) Power Supply
    • STI-34106 — Keyfob
    • STI-34109 — Repeater
    • STI-6200WIR / STI-6200WIR4 — Wireless Fire Extinguisher Theft Stopper (with/without Receiver)
    • STI-6400WIR / STI-6400WIR4 — Wireless Exit Stopper Door Alarm (with/without Receiver)
    • STI-6517A/B/C/D — Wireless Stopper Station Shield variants

    Manufacturer Contact

    Safety Technology International, Inc. — 2306 Airport Rd, Waterford, MI 48327, USA. Phone: 248-673-9898. info@sti-usa.com | www.sti-usa.com

    Safety Technology International Ltd — Taylor House, 34 Sherwood Road, Bromsgrove, Worcestershire B60 3DR, England. Tel: +44 (0)1527 520 999. info@sti-emea.com | www.sti-emea.com