September 08, 2026 6 min read
Full installation and programming guide for the SkylinkHome™ Wireless 3-Way On/Off/Dimmer Kit, model SK7.
Installation instructions for the SkylinkHome™ Wireless 3-Way On/Off/Dimmer Kit, model SK7 — replace an existing wall switch with a wireless-controlled Wall Switch Receiver, then pair it with a Wireless Wall Switch Transmitter to control lighting from anywhere.
Turn off power to the circuit breaker before installing. Failure to turn off power at the circuit breaker can result in electrical shock, causing severe or fatal injury. If you are uncertain or uncomfortable performing this installation, consult a qualified electrician. For indoor use only. Do not use this product to control loads over the specified maximum rating.
| Part | Description | Qty |
|---|---|---|
| A | Wall Switch Receiver | 1 |
| B | Wireless Wall Switch Transmitter | 1 |
| C | Wire Nuts | 3 |
| D | Screws and anchors | 2 |
| E | Double-sided Foam Tape | 2 |
| Spec | Value |
|---|---|
| Input Voltage | 120V AC, 60Hz |
| Standby Current | 0.2mA |
| Minimum Load | 10W |
| Maximum Load | 300W at 120VAC |
| Operating Frequency | 318MHz |
| Operational Temperature | -4°F to 140°F (-20°C to 60°C) |
| Humidity | 5% – 95% |
| Range | Up to 500 feet in open area |
Note: The receiver operates incandescent or dimmable compact fluorescent light up to 300W at 120VAC. Bulbs must be dimmable to achieve the dimming function. If replacing an existing 3-way switch, disable one switch and replace the other with the Wall Switch Receiver.
The transmitter ships with a lithium battery pre-installed — remove the battery isolator tag before installing.
Wall Switch Receiver: Tap the metal touch plate to turn lights on/off. Tap and hold to dim or brighten.
Wireless Wall Switch Transmitter: Push the pad from one position to the other to turn lights on/off. To dim/brighten: push the pad to turn on, then press and hold the same (upper) pad.
Warning: this erases all previously programmed devices — you'll need to re-program anything you want to keep.
Factory default operating mode is On/Off. Non-dimmable loads must always run in On/Off Mode — using a non-dimmable CFL under Dimming Mode may damage it.
When activated, the connected light flashes for a set interval, then turns off. Complete the sequence within 15 seconds or restart from step 1.
When activated, the light stays on for a predetermined interval, then turns off.
For transmitters programmed to Flashing Alert or Countdown Timer Mode. Connected light must be off with both blue LEDs on. Press and hold the learn button for 3 seconds until the lower blue LED flashes — the number of flashes indicates the duration, changing every 6 seconds while held.
| Number of Flashes | Timer Duration |
|---|---|
| 1 | 1 min |
| 2 | 5 min |
| 3 | 15 min |
| 4 | 30 min |
| 5 | 60 min |
To stop a countdown early, press a programmed button for regular mode. Note: if another timer signal is received mid-countdown, the timer resets and extends the on-period.
The red LED lights for one second when a fresh battery is installed.
| Problem | Solution |
|---|---|
| Receiver LEDs and connected load will not turn on | Ensure wires are connected correctly (see Section 1) and held together, side by side, inside the wire nuts. Check the circuit breaker is on. |
| My switch has more than 3 wires in the wall box | If there are white (neutral) wires, connect them together with a wire nut. Only connect Load and Live wires to the Wall Switch Receiver. |
| Wall Switch Receiver is getting warm to the touch | This is normal. Ensure the connected load does not exceed the maximum rating. |
| Range is decreasing | Keep the antenna wire as straight as possible; route it directly into the drywall or through the wall box hole. |
| Light takes a long time to turn off when set to Timer Mode | Confirm the desired timer duration is set. Check that no other Timer Mode signals are being received, which would extend the ON period. |
| Can I connect a 600W light? | No — purchase the Skylink Wall Switch Receiver (WE-001/WE-318) instead. |
| Can I dim a CFL with the Wall Switch Receiver? | Only if the CFL itself is rated dimmable. |
The SK7 kit is expandable with up to 8 Skylink wireless transmitters, including: Wireless Wall Switch (TB-318), Motion Sensor (ID-318), Snap-On Remote (TM-318), Keychain Remote (LK-318), LCD Deluxe Remote (TD-318), Snap-On Cover (TM-001), and the TC-Series wireless remote controls (1–14 buttons).
One-year warranty against defects in materials and workmanship from date of purchase. Does not cover normal wear and tear or batteries. Call 1-800-304-1187 for repair or replacement parts.
Skylink Group · 17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 · support@skylinkhome.com · 1-800-304-1187 (Mon–Fri, 9am–5pm EST) · www.skylinkhome.com
Sign up to get the latest on sales, new releases and more …