September 08, 2026 5 min read
Installation and setup guide for the Sensaphone Sentinel cloud-based environmental and alarm monitoring system with 12 sensor inputs.
Installation and setup guide for the Sensaphone Sentinel — a cloud-based environmental and alarm monitoring system with 12 sensor inputs, battery backup, and web/app-based alert delivery.
The Sentinel is an easy, cost-effective, cloud-based monitoring and data logging system that notifies you when equipment or conditions go awry. Internet browser-based programming makes it usable from any computer or tablet. Monitored conditions can include temperature, humidity, pressure, flow, leak detection, UPS systems, and more. Multiple users can be notified immediately of any detected problems via voice call, email, or SMS (voice calls and text messages require a premium subscription plan). An internal battery backup keeps the unit running through a power failure.
The Sentinel is housed in a 5.5" x 5.5" x 1.5" enclosure that mounts on a wall or back panel. Front panel layout includes: (1) Acknowledge/Standby button, (2) On/Off switch, (3) Power, Online, Standby LEDs, (4) Alarm LEDs, (5) power jack, (6) Ethernet jack, (7) sensor input terminal strip, (8) relay output.
Technical note: The Sentinel communicates over port 443 (TCP, SSL) — this must be open for outbound communication. It also uses port 123 (UDP) for NTP clock synchronization.
The Sentinel is compatible with normally open/normally closed contacts, 2.8K and 10K temperature sensors, and 4–20mA current sources. The zone terminal strip has upper (positive) and lower (ground, common) terminal levels for up to 12 sensors.
Warning: Inputs are designed for low voltage signals only. Do NOT connect voltages greater than 3.3V, and never connect 120VAC to the inputs.
| Wiring Distance | Minimum Wire Gauge |
|---|---|
| 700' | #24 AWG |
| 1500' | #22 AWG |
| 2500' | #20 AWG |
Use shielded cable in electrically noisy environments or for long sensor runs (Sensaphone part FGD-0010, 22-gauge, 50' lengths). Route power/network cables separately from sensor wiring, cross paths perpendicularly, don't run sensor wiring in the same conduit as AC power, and tie any shield to the input ground terminal.
The Dashboard lists all devices on your account with counts of unacknowledged alarms, current alarms, units online, and units offline, plus a map showing device locations (green = OK, red = alarm). The Device Details page shows live sensor values, min/max recorded values, and status for every zone, with buttons to reach Configuration, Alarm Delivery, and Logs.
Standby mode temporarily suspends alarm detection so onsite personnel can perform maintenance. Enter it via the Dashboard's Action dropdown or by holding the front-panel button 5 seconds; it persists for the time set on the Configure Device page (or until manually exited), with the Standby LED lit as an indicator.
Key zone parameters you can program per input: Enable/Disable, Name, sensor Type, Units, Calibration offset, Alarm Low/High thresholds, Table Low/High (for 4-20mA range), Alarm Delivery Enable/Disable, Recognition Time (how long an alarm condition must persist before it's valid), Alarm Hold Time (prevents redundant re-notifications), Return to Normal notification, Alarm Reset (re-sends alarm messages if a fault isn't corrected — recommended no lower than 30 minutes), and Datalogging Mode (Continuous or While In Alarm, with separate Normal/Alarm logging intervals).
Permission levels: Administrator (full access to all devices), Supervisor (access to chosen devices, can create Supervisor-or-lower users), User (dashboard access to chosen devices only), and None (no website access). Alarm delivery options per user: Disabled, Inform Only (notified but can't acknowledge), or Allow Acknowledgement. Contact methods include phone, text, and email — phone/text require a Premium Ethernet or Cellular subscription; email delivery is free.
The relay output (rated up to 30VAC/VDC 1A) can control a light, siren, or other low-voltage device. It operates in Manual mode (turn ON/OFF via web/app) or Automatic mode, where it triggers based on selected zones:
| Part # | Description |
|---|---|
| BAT-0032 | Sentinel Battery |
| FGD-0006 | Magnetic Reed Switch |
| FGD-0007 | Passive Infra-Red Detector |
| FGD-0010 | 50' two-conductor #22AWG shielded cable |
| FGD-0013 | Spot Water Detector |
| FGD-0022 | Temp° Alert |
| FGD-0027 | Humidistat |
| FGD-0049 | Smoke Detector with Built-in Relay |
| FGD-0052 | Humidity 4-20mA Transmitter |
| FGD-0056 | Zone Water Detector w/Water Rope |
| FGD-0065 | Carbon Monoxide Sensor |
| FGD-0066 | Air Quality Sensor |
| FGD-0100 | 2.8k Remote Temperature Sensor |
| FGD-0101 | 2.8k Weatherproof Temperature Probe |
| FGD-0102 | 10k Weatherproof Temperature Probe |
| FGD-0205 | Multi-Point Wireless I/O System |
| FGD-0301 | Pressure Sensor |
| FGD-0303 | Vibration Sensor |
Rated for 1A 30VAC / 1A 30VDC maximum
1 minute to 24 hour sampling rate, user-programmable channel selection across zones 1–12
SENSAPHONE® Remote Monitoring Solutions, 901 Tryens Road, Aston, PA 19014. Technical support: 610-558-2700, 8:00 AM–5:00 PM ET, M-F.