  • RISCO LuNAR PR — 360° Ceiling Mount PIR Motion Detector Installation Manual

    September 08, 2026 3 min read

    Installation manual for the RISCO LuNAR PR 360-degree ceiling-mount PIR motion detector.

    Full text manual (for reference)

    Installation manual for the RISCO LUNAR PR — a 360° ceiling-mount PIR (passive infrared) motion detector designed for wide-area interior coverage.

    General Description

    The LUNAR PR 360° ceiling mount PIR is designed with state-of-the-art components for reliable operation across a wide range of applications. It has a wide 110° angle, 360° overview, and uses dual-element pyroelectric technology for superior RFI/EMI protection. It also has automatic temperature compensation.

    Installation Procedure

    1. Preliminary decisions: Study the space to be protected to decide on the best location for coverage. This unit is usually installed above the center of the protected area. The lens provides detection sectors arranged in three all-round optical levels: 12 external sectors, 12 middle sectors, and 6 internal sectors. Do not mount in direct sunlight or near a heat source (stove, radiator, etc.); detection sectors should point toward the floor, not toward windows or curtains.
    2. Frontal cover removal: Hold the unit with its base in the palm of your hand and turn the cover clockwise to open. This releases the 4 latches locking the cover to the base.
    3. Opening, mounting, and cable hole: Open the appropriate knockouts for mounting and wiring. Insert the cable through the opened hole and mount the bottom part in its final location. Seal the cable hole and any other opening with a sealant (RTV or similar). Use the 4 marks on the back of the package for mounting.
    4. Mounting: Drill mounting holes using the 4 marks on the back side of the package.
    5. Terminal wiring: Connect wires to the terminal strip at the lower-right of the PC board:
      Terminal Description
      (-) (+) 12 VDC DC voltage (9 to 16 VDC)
      N.C. Normally closed alarm contacts
      TAMPER Anti-tamper circuit
      Note: Ensure the cover is installed after mounting and wiring — do not test the detector with the cover open.
    6. Walk test: The DIP switch on the left side of the PC board has two sections: "PULSES" and "LED." Set PULSES to "1" and LED to "ON." With LUNAR PR closed and powered, the LED lights each time detection occurs so operation can be checked. After walk testing, switch LED to "OFF" so the detector works normally without alerting an intruder that they've been detected.
    7. Setting the pulse count: The number of pulses needed to activate the alarm can be set to "1," "2," or "3" via the PULSES DIP switch section. Only one switch should be set to ON at a time.

    Optical Features

    The lens fitted in the LUNAR PR provides detection sectors (beams) arranged in three all-round optical levels: 12 external sectors, 12 middle sectors, and 6 internal sectors — ensuring the best coverage of the protected area.

    Specifications

    Electrical

    • Detection technology: Dual element PIR
    • Current consumption: 15 mA at 12 VDC
    • Supply voltage: 9-16 VDC regulated
    • Alarm contact: 24 VDC, 50 mA
    • Anti-tamper: Normally closed, 24 VDC, 0.5 A
    • Pulse count: Selectable 1-3
    • Temperature compensation: Thermistor
    • RF immunity: 30V/m up to 1 GHz
    • Walk test: 1 LED

    Optical

    • Lens: Wide angle spherical Fresnel
    • Coverage: 110° angle, 360° overview
    • Detection zones: 3 optical levels — 12 external sectors, 12 middle sectors, 6 internal sectors

    Physical

    • Weight: 112 g (4 oz)
    • Size: ⌀ 135 x 27 mm

    Environmental

    • Operating temperature: 0°C to 55°C (32°F to 131°F)
    • Storage temperature: -20°C to 60°C (-4°F to 140°F)

    Warranty

    RISCO Group warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of sale. RISCO's obligation under this warranty is expressly limited to repairing or replacing, at RISCO's option, any product not meeting specifications within a reasonable time after delivery. RISCO makes no warranty of merchantability or fitness for any particular purpose, and disclaims liability for consequential or incidental damages.

    Warning: This product should be tested at least once a week.