  • SECO-LARM SK-B111-PQ Indoor Bluetooth Keypad/Proximity Reader — Additional Info

    September 08, 2026 2 min read

    Additional installation and wiring information for the SECO-LARM ENFORCER SK-B111-PQ Indoor Bluetooth Single-Gang Keypad / Proximity Reader.

    Full text manual (for reference)

    Additional installation and wiring information for the SECO-LARM ENFORCER SK-B111-PQ Indoor Bluetooth® Single-Gang Keypad / Proximity Reader.

    What's in the Box

    • 1x SK-B111-PQ ENFORCER Indoor Bluetooth® Keypad / Proximity Reader
    • 2x Security screws + 1x Security screw bit
    • 11x Crimp connectors, 1x Diode, 1x Varistor
    • 1x 11-Wire Wiring Harness
    • 1x Quick Installation/Setup Guide + 1x Additional Information sheet

    Specifications

    Operating voltage 9~25 VDC
    Current draw (standby) 50mA @ 12VDC, 28mA @ 24VDC
    Current draw (active max) 58mA @ 12VDC, 33mA @ 24VDC
    Outputs — Form C 2.0A @ 30VDC
    Outputs — Tamper alarm 100mA @ 30VDC (solid state N.C.)
    Egress input N.O. Ground
    Door sensor input N.C. Ground
    Proximity reader EM 125kHz
    Faceplate material Stainless steel, ABS/PC plastic
    Operating humidity 0–95%, non-condensing
    Operating temperature -4° to 122° F (-20° to 50° C)
    Dimensions 2-3/4" x 4-1/2" x 1-1/4" (70 x 114 x 31 mm)
    Weight 3.75-oz (107g)

    Wiring Harness Color Code

    Wire Function
    Red Power (+)
    Black Power (–)
    White COM
    Blue N.O. fail-secure
    Yellow N.C. fail-safe
    Green pair To RTE (request-to-exit) button
    Brown pair To door sensor
    Orange pair To N.C. tamper

    Important: Use the blue wire for fail-secure applications and the yellow wire for fail-safe applications — insulate the unused wire's end with electrical tape. To protect the relay, install the enclosed diode (cathode toward the positive side) for DC-powered locks, or the varistor (MOV) for AC-powered locks and electromagnetic locks — unless your lock has a diode/varistor already built in. Failure to do so voids the warranty.

    Installation Overview

    1. Connect wiring: Feed wires into a non-metal back box and connect to the wiring harness using the included crimp connectors.
    2. Plug wiring harness in: Plug the harness into the terminal block on the keypad, noting the orientation of the tabs.
    3. Mount keypad to back box: Use the provided security screws to install the keypad into the back box, taking care not to crimp wires or loosen connections.

    Important: Do not install into any type of metal back box — this will affect Bluetooth® reception. A reset jumper (used only to restore factory defaults) is accessible on the keypad's back — see the Installation Manual for the reset procedure.

    Compliance

    FCC ID: K7TRB8762 | IC ID: 2377ARB8762. This device complies with Part 15 of the FCC Rules and Industry Canada's licence-exempt RSS standards. Any change or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

    Warranty

    Warranted against defects in material and workmanship for one (1) year from the date of sale to the original customer. SECO-LARM's obligation is limited to repair or replacement of defective parts, transportation prepaid.

    Manufacturer