Additional installation and wiring information for the SECO-LARM ENFORCER SK-B111-PQ Indoor Bluetooth Single-Gang Keypad / Proximity Reader.
Additional installation and wiring information for the SECO-LARM ENFORCER SK-B111-PQ Indoor Bluetooth® Single-Gang Keypad / Proximity Reader.
| Operating voltage | 9~25 VDC |
| Current draw (standby) | 50mA @ 12VDC, 28mA @ 24VDC |
| Current draw (active max) | 58mA @ 12VDC, 33mA @ 24VDC |
| Outputs — Form C | 2.0A @ 30VDC |
| Outputs — Tamper alarm | 100mA @ 30VDC (solid state N.C.) |
| Egress input | N.O. Ground |
| Door sensor input | N.C. Ground |
| Proximity reader | EM 125kHz |
| Faceplate material | Stainless steel, ABS/PC plastic |
| Operating humidity | 0–95%, non-condensing |
| Operating temperature | -4° to 122° F (-20° to 50° C) |
| Dimensions | 2-3/4" x 4-1/2" x 1-1/4" (70 x 114 x 31 mm) |
| Weight | 3.75-oz (107g) |
| Wire | Function |
|---|---|
| Red | Power (+) |
| Black | Power (–) |
| White | COM |
| Blue | N.O. fail-secure |
| Yellow | N.C. fail-safe |
| Green pair | To RTE (request-to-exit) button |
| Brown pair | To door sensor |
| Orange pair | To N.C. tamper |
Important: Use the blue wire for fail-secure applications and the yellow wire for fail-safe applications — insulate the unused wire's end with electrical tape. To protect the relay, install the enclosed diode (cathode toward the positive side) for DC-powered locks, or the varistor (MOV) for AC-powered locks and electromagnetic locks — unless your lock has a diode/varistor already built in. Failure to do so voids the warranty.
Important: Do not install into any type of metal back box — this will affect Bluetooth® reception. A reset jumper (used only to restore factory defaults) is accessible on the keypad's back — see the Installation Manual for the reset procedure.
FCC ID: K7TRB8762 | IC ID: 2377ARB8762. This device complies with Part 15 of the FCC Rules and Industry Canada's licence-exempt RSS standards. Any change or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Warranted against defects in material and workmanship for one (1) year from the date of sale to the original customer. SECO-LARM's obligation is limited to repair or replacement of defective parts, transportation prepaid.
SECO-LARM U.S.A., Inc. — 16842 Millikan Avenue, Irvine, CA 92606. Phone: (949) 261-2999 / (800) 662-0800. Web: www.seco-larm.com.