SECO-LARM ENFORCER SK-2612-SPQ Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader — full programming reference for a 1,000-user weatherproof (IP66) access keypad with EM proximity card support.
Installation and programming guide for the SECO-LARM ENFORCER SK-2612-SPQ Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader. This weatherproof (IP66), extreme-cold-rated (-40°F) keypad supports up to 1,000 users (998 regular + 2 duress), works standalone or integrates with an external Wiegand controller/reader, and is fully programmable from the keypad itself — no external programmer required.
| Operating Voltage | 9~18 VDC |
| Current Draw | Standby: 40mA@12VDC; Active: 105mA@12VDC max |
| Outputs | Form C: 2A@12VDC; Alarm: 2.5A@12VDC; Wiegand: 26~37 bits, PIN output bits 4/8/10 |
| Egress Input | N.O. ground |
| Door Sensor Input | N.C. ground |
| Wiegand Input | 26~37 bits, PIN input bits 4/8/10 |
| Card Type | EM 125kHz |
| Enclosure | Black ABS plastic |
| Operating Temperature | -40° to 140° F (-40° to 60° C) |
| Operating Humidity | 10~90% non-condensing |
| Dimensions | 1 15/16"x4¾"x15/16" (49x120x24mm) |
| Weight | 5.8 oz (165g) |
| Color | Function | Description |
|---|---|---|
| Red | Power (+) | Connect to +12VDC power supply |
| Black | Ground (–) | Connect to ground |
| Yellow | Egress Input | N.O. pushbutton contact to ground |
| Brown | Door Sensor | Connect to magnetic contact/door sensor |
| Blue / Purple / Orange | Output N.O. / COM / N.C. | Relay output, max 3A@12VDC |
| Gray | Alarm Output | Transistor ground output, max 2.5A@12VDC |
| Green / White | Data 0 / Data 1 | Wiegand controller |
Note: For DC-powered electric strikes, connect the included diode as close as possible and in parallel with the strike to absorb interference. Do not use a diode with electromagnetic locks or AC-powered strikes.
Important safety note: If used with a mechanically operated door or gate, mount the unit at least 15' (5m) away to prevent users from being crushed or pinned.
All programming is done directly on the keypad using single-digit function codes. Enter base programming mode with the master programming code (default: see manual), then press a function code to enter that function's programming mode, enter parameters, and confirm.
| Function Code | Purpose | Default |
|---|---|---|
| 0 | Master programming code | Default 123456, 6 digits |
| 1 | Add user/duress cards/codes | Must be programmed |
| 2 | Delete user/duress cards/codes | Must be programmed |
| 3 | Output mode/time | Momentary, 5 seconds |
| 4 | Access mode / security level | Card or code |
| 5 | External alarm/time | 1 minute |
| 6 | Wrong-code lockout/alarm | Disabled |
| 7 | Sounds/LED/backlight; operation mode | All ON; stand-alone |
| 8 | Wiegand output/input format | 26 bits, PIN bits 4 |
| 9 | Interlock mode; duplicate to another device | Interlock OFF |
Cards can be added individually by reading them, by entering printed card numbers, or in a large batch (up to 998 in one operation, consecutive card numbers to consecutive user IDs). A Master Add Card lets you add cards without entering programming mode at all — present it, add cards, then present it again to exit. User codes (4~6 digits) are added similarly with function code 1; the code 8888 is reserved and cannot be assigned.
Delete individually by user ID, by user code, or by reading the card (function code 2), or use the Master Delete Card for quick deletion outside programming mode. All users can be wiped at once (retaining configuration) with the master programming code.
Assign duress codes/cards specifically to user IDs 998 and 999 — using them unlocks the door while silently triggering the alarm. The duress alarm cannot be silenced until the programmed alarm time expires, even if a valid code is entered (it restarts the timer instead).
Two keypads can be wired together (same wire colors in parallel) so that only one door can be unlocked at a time — enable via function code 9. The keypad can also operate as a Wiegand controller (connected to an external Wiegand reader) or as a plain Wiegand reader connected to an external access control panel — set the mode via function code 7 and the Wiegand bit format via function code 8.
Connect up to 10 additional keypads in parallel (matching wire colors) and use function code 9 on the source unit to transfer all user data — takes about 3 minutes for 1,000 users and overwrites existing data on the receiving units.
| Issue | Solution |
|---|---|
| Unit fails to accept a new user/duress code/card | Ensure User ID is 0-997 (users) or 998/999 (duress); ensure code is 4-6 digits and not already assigned |
| Unit fails to respond to a programmed user code/card | Ensure the unit is in standby mode (steady red LED) |
Requires a connected Request-to-Exit (RTE) button. Power off, then hold the egress button while powering on for ~10 seconds until 2 beeps sound and LED turns orange; release the button. Wait ~30 seconds for the LED to turn red (reset complete), or within 30 seconds read two cards to set new Master Add/Delete cards. User information is retained through a factory reset.
1-year limited warranty against defects in material and workmanship under normal service, from date of sale to the original customer. SECO-LARM's obligation is limited to repair or replacement of defective parts (transportation prepaid by purchaser).