  • SECO-LARM SK-2612-SPQ — ENFORCER Outdoor Wiegand Keypad with Proximity Reader

    September 08, 2026 5 min read

    SECO-LARM ENFORCER SK-2612-SPQ Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader — full programming reference for a 1,000-user weatherproof (IP66) access keypad with EM proximity card support.

    Full text manual (for reference)

    Installation and programming guide for the SECO-LARM ENFORCER SK-2612-SPQ Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader. This weatherproof (IP66), extreme-cold-rated (-40°F) keypad supports up to 1,000 users (998 regular + 2 duress), works standalone or integrates with an external Wiegand controller/reader, and is fully programmable from the keypad itself — no external programmer required.

    Key Features

    • 1,000 users (up to 998 users + 2 duress users)
    • User code length: 4~6 digits
    • 9~18 VDC operation, low current draw (105mA max)
    • Form C relay output — 2A@12VDC, adjustable output time 0.5~99s or toggle
    • Built-in tamper alarm and external alarm output
    • Backlit keypad with multicolor status LED
    • EM 125kHz proximity card reader
    • Outdoor rated IP66; operates down to -40°F (-40°C)
    • EEPROM memory protects programmed data through power loss
    • Egress input lets users exit without entering a code
    • Can serve as a Wiegand reader or controller — output/input 26~37 bits
    • 2-door interlock support
    • Easy transfer of users to additional devices

    Specifications

    Operating Voltage 9~18 VDC
    Current Draw Standby: 40mA@12VDC; Active: 105mA@12VDC max
    Outputs Form C: 2A@12VDC; Alarm: 2.5A@12VDC; Wiegand: 26~37 bits, PIN output bits 4/8/10
    Egress Input N.O. ground
    Door Sensor Input N.C. ground
    Wiegand Input 26~37 bits, PIN input bits 4/8/10
    Card Type EM 125kHz
    Enclosure Black ABS plastic
    Operating Temperature -40° to 140° F (-40° to 60° C)
    Operating Humidity 10~90% non-condensing
    Dimensions 1 15/16"x4¾"x15/16" (49x120x24mm)
    Weight 5.8 oz (165g)

    Wiring Chart

    Color Function Description
    Red Power (+) Connect to +12VDC power supply
    Black Ground (–) Connect to ground
    Yellow Egress Input N.O. pushbutton contact to ground
    Brown Door Sensor Connect to magnetic contact/door sensor
    Blue / Purple / Orange Output N.O. / COM / N.C. Relay output, max 3A@12VDC
    Gray Alarm Output Transistor ground output, max 2.5A@12VDC
    Green / White Data 0 / Data 1 Wiegand controller

    Note: For DC-powered electric strikes, connect the included diode as close as possible and in parallel with the strike to absorb interference. Do not use a diode with electromagnetic locks or AC-powered strikes.

    Installation Overview

    1. Choose a mounting location at a height convenient for users.
    2. Remove the security screw, then carefully slide the keypad off the housing base.
    3. Use the housing base as a template to mark and drill mounting/wiring holes (choose either pair of mounting holes; wiring hole ø3/8"/9mm minimum).
    4. Run wiring through the wall, thread through the keypad base center, and connect per the wiring chart.
    5. Mount the base with the included screws/anchors, ensuring correct orientation.
    6. Reattach the keypad to the base and secure with the security screw.
    7. For weatherproof installation, apply a bead of silicone sealant where the base meets the wall.

    Important safety note: If used with a mechanically operated door or gate, mount the unit at least 15' (5m) away to prevent users from being crushed or pinned.

    Programming Overview

    All programming is done directly on the keypad using single-digit function codes. Enter base programming mode with the master programming code (default: see manual), then press a function code to enter that function's programming mode, enter parameters, and confirm.

    Function Code Purpose Default
    0 Master programming code Default 123456, 6 digits
    1 Add user/duress cards/codes Must be programmed
    2 Delete user/duress cards/codes Must be programmed
    3 Output mode/time Momentary, 5 seconds
    4 Access mode / security level Card or code
    5 External alarm/time 1 minute
    6 Wrong-code lockout/alarm Disabled
    7 Sounds/LED/backlight; operation mode All ON; stand-alone
    8 Wiegand output/input format 26 bits, PIN bits 4
    9 Interlock mode; duplicate to another device Interlock OFF

    Security Levels (Access Modes)

    • Card only — user must present a card.
    • Card or code (default) — either a card or a code works.
    • Card + code — both required; card assigned first gets a temporary code 8888 that must be changed before use.
    • Multiple user codes/cards — 2-9 codes/cards required in sequence (within 5 seconds of each other), no repeats.

    Adding Users

    Cards can be added individually by reading them, by entering printed card numbers, or in a large batch (up to 998 in one operation, consecutive card numbers to consecutive user IDs). A Master Add Card lets you add cards without entering programming mode at all — present it, add cards, then present it again to exit. User codes (4~6 digits) are added similarly with function code 1; the code 8888 is reserved and cannot be assigned.

    Deleting Users

    Delete individually by user ID, by user code, or by reading the card (function code 2), or use the Master Delete Card for quick deletion outside programming mode. All users can be wiped at once (retaining configuration) with the master programming code.

    Duress Codes/Cards

    Assign duress codes/cards specifically to user IDs 998 and 999 — using them unlocks the door while silently triggering the alarm. The duress alarm cannot be silenced until the programmed alarm time expires, even if a valid code is entered (it restarts the timer instead).

    Two-Door Interlock & Wiegand Modes

    Two keypads can be wired together (same wire colors in parallel) so that only one door can be unlocked at a time — enable via function code 9. The keypad can also operate as a Wiegand controller (connected to an external Wiegand reader) or as a plain Wiegand reader connected to an external access control panel — set the mode via function code 7 and the Wiegand bit format via function code 8.

    Duplicating Users to Other Keypads

    Connect up to 10 additional keypads in parallel (matching wire colors) and use function code 9 on the source unit to transfer all user data — takes about 3 minutes for 1,000 users and overwrites existing data on the receiving units.

    Troubleshooting

    Issue Solution
    Unit fails to accept a new user/duress code/card Ensure User ID is 0-997 (users) or 998/999 (duress); ensure code is 4-6 digits and not already assigned
    Unit fails to respond to a programmed user code/card Ensure the unit is in standby mode (steady red LED)

    Resetting to Factory Default

    Requires a connected Request-to-Exit (RTE) button. Power off, then hold the egress button while powering on for ~10 seconds until 2 beeps sound and LED turns orange; release the button. Wait ~30 seconds for the LED to turn red (reset complete), or within 30 seconds read two cards to set new Master Add/Delete cards. User information is retained through a factory reset.

    Accessories

    • PR-K1K1-AQ — Proximity key fobs (packs of 10)
    • PR-K1S1-A — Proximity cards (packs of 10)

    Important Notes

    • Ensure proper weatherproof sealing where the housing base meets the wall — incorrect mounting can lead to moisture exposure, electric shock risk, device damage, and voided warranty.
    • Installers/users are responsible for compliance with all applicable laws and codes related to locking and egress devices.
    • FCC ID: K4E2612SPQ. Complies with FCC Part 15.

    Warranty

    1-year limited warranty against defects in material and workmanship under normal service, from date of sale to the original customer. SECO-LARM's obligation is limited to repair or replacement of defective parts (transportation prepaid by purchaser).