    Installation and programming manual for the SECO-LARM SK-1323 and SK-2323 series outdoor access control keypads.

    Full text manual (for reference)

    Full instruction manual for the SECO-LARM ENFORCER® Outdoor Stand-Alone Weatherproof Keypads — models SK-2323-SDQ, SK-2323-SPQ (Mullion-Style) and SK-1323-SDQ, SK-1323-SPQ (Sealed-Environment), covering installation, wiring, programming, and troubleshooting.

    Model Comparison

    Model Style 2 Relay Outputs Backlit Keys Proximity Reader
    SK-2323-SDQ Mullion-Style ✓ ✓
    SK-2323-SPQ Mullion-Style ✓ ✓ ✓
    SK-1323-SDQ Sealed-Environment ✓ ✓
    SK-1323-SPQ Sealed-Environment ✓ ✓ ✓

    Features

    • 12~15 VDC operation
    • 1,010 user codes (up to 1,000 Output #1 codes + 10 Output #2 codes)
    • 2 Form C relays, each rated 1 Amp @ 30VDC, with programmable output time from 1~99 seconds or toggle
    • Output #2 can be programmed for use with a doorbell
    • 2 egress inputs and 1 door sensor input
    • Backlit keys for nighttime use
    • Mounts to a single-gang back box
    • All programming done directly from the keypad — no external programmer needed
    • EEPROM memory protects programmed data through power loss
    • Optical tamper for added security
    • Circuitry potted with epoxy for outdoor use; IP65 weatherproof rating, rugged aluminum construction
    • Built-in proximity card reader (SK-2323-SPQ and SK-1323-SPQ only)

    Specifications

    • Operating voltage: 12~15 VDC
    • Current draw: 40mA @ 12VDC standby, 70mA @ 12VDC active
    • Relay outputs: Output #1 and Output #2, each 1A @ 30VDC, Form C, NO/NC/COM
    • Egress inputs: Input #1 and #2, N.O. ground
    • Door sensor input: N.C. ground
    • Tamper sensor: Optical
    • Operating temperature: -4° to 122°F (-20° to 50°C)
    • Keypad LED life: 60,000 hours (over 6.8 years)
    • Weight: SK-1323 series 1lb 2oz (510g); SK-2323 series 11oz (312g)
    • Proximity reader frequency (SPQ models): 125kHz
    • Proximity reader distance (SPQ models): 1-15/16" (5cm)

    Wiring Diagram

    • Black – Ground (−)
    • Red – Power (+), 12~15 VDC
    • Brown – Door Sensing Input (N.C.)
    • Orange – Egress Input #1 (N.O.), triggers Output #1
    • Yellow – Egress Input #2 (N.O.), triggers Output #2
    • Green – Earth Ground
    • Pink – Output #1 (COM); Aqua – Output #1 (N.C.); unlabeled Output #1 (N.O.)
    • Blue – Output #2 (N.O.); Purple – Output #2 (COM); Gray – Output #2 (N.C.)

    Earth Ground should be connected via 18AWG wire (minimum 22AWG) to a grounded metal conduit, cold water pipe, or grounding rod to protect against static discharge damage. When wiring electric strikes, connect the included diode and metal oxide varistor (MOV) in parallel with the strike to absorb EMI — do not use with electromagnetic locks.

    Installation

    1. Find a suitable mounting location — not too high or low for typical users.
    2. Using the included Torx wrench, unscrew the security screw on the bottom of the mounting bracket.
    3. Carefully remove the keypad from the mounting bracket.
    4. Drill the 4 designated mounting holes (use the included mounting template if needed).
    5. Secure the mounting bracket with the 4 included mounting screws (use included screw anchors for brick/drywall).
    6. For surface wiring, mount to a single-gang box using the single-gang mounting points.
    7. Connect wiring per the wiring diagram.
    8. Reattach the keypad to the mounting base and tighten the security screw with the Torx wrench.

    Important: If used with a mechanically operated door or gate, mount the keypad at least 5' (1.5m) from the door/gate to prevent crushing/pinning injuries. Always disconnect power before servicing. The keypad must be grounded with a minimum 22AWG wire to the green Earth Ground wire. All wiring and programming should be done by a professional installer.

    First-Time Programming

    1. Enter Programming Mode by entering the Master Code twice (default: 1-2-3-4-5, 1-2-3-4-5).
    2. Set the Output #1 Access Mode (SPQ models only, required for user codes to work): Enter [0], then [0][0] for user cards only (default), [0][1] for either card or code, or [0][2] for card with code.
    3. Program a new Master Code: Enter [3], then enter the new 5-digit Master Code twice.
    4. Program an Output #1 User Code: Enter a 3-digit user ID (000-999), then a new 5-digit user code. Up to 1,000 Output #1 codes can be programmed; each code must be unique and different from the Master Code or any Output #2 code.

    Programming Reference

    Function Steps
    Change Master Code Enter [3], then new 5-digit Master Code twice
    Program Output #1 user code Enter 3-digit user ID (000-999), then 5-digit code
    Program Output #2 user code Enter [4], 2-digit user ID (00-09), then 5-digit code
    Delete Output #1 user Enter 3-digit user ID, then [9]
    Delete Output #2 user Enter [4], 2-digit user ID, then [9]
    Set Output #1 timer Enter [1], then seconds (00-99) or [0][0] for toggle
    Set Output #2 timer Enter [5], then seconds (00-99) or [0][0] for toggle
    Set Output #2 function Enter [2], then [0][1] for user codes or [0][2] for doorbell
    Set tamper alarm Enter [6], then [0][1] OFF or [0][2] ON
    Program/delete Master Card Enter [7], then swipe card (or [9] to delete)

    Codes are 5 digits. To exit Programming Mode, press [#]. The keypad auto-exits after 30 seconds of inactivity.

    Using the Keypad

    Enter the user code directly (not the user ID number) to activate an output — e.g., if the Output #1 code is 54321, press 5-4-3-2-1. To use a user card, hold it in front of the keypad; the keypad beeps once read. If a wrong code is entered or wrong card swiped 5 consecutive times, the keypad locks out for 1 minute — further attempts during lockout extend the lockout time.

    LED & Audible Indicators

    Left LED Right LED Keypad Status
    OFF Green Power ON
    OFF Orange Programming Mode
    Green Green Relay 1 activated
    Red Green Relay 2 activated
    Orange Green Relay 1 and 2 both activated
    Orange Orange Restoring factory defaults
    OFF OFF Power OFF / clearing user codes

    Audible tones: 1 long tone = confirmation; short tone = key press; 2 short tones = invalid entry; 3 short tones = code/card denied; constant short tones = alarm triggered; 6 short + 1 long = all user codes deleted; no tone = wrong code lockout.

    Resetting

    Delete all users: Enter [8][8][8]. This deletes all codes/cards but keeps the Master Code and other settings.

    Restore factory settings: Enter [8][9][9]. This clears all users and resets the Master Code to 12345 (and Output #1 Access Mode to proximity cards only, on SPQ models).

    Manually reset a forgotten Master Code: Disconnect power, hold the # key, reconnect power while still holding #. After 3 seconds the keypad beeps to confirm — Master Code is now 12345 (Master Card and user data are unaffected).

    Troubleshooting

    Problem Solution
    Keypad won't accept codes/cards Verify Output #1 Access Mode is set to accept user codes. If a wrong entry was just made, the keypad may be in Wrong Code Lockout — wait 1 minute.
    Output #2 will not activate Verify Output #2 is programmed for the correct function.
    Egress input not working Check egress wiring against the wiring diagram.
    Relay output will not stop Make sure the output isn't set to toggle mode.
    User code will not program Delete the existing user before programming a new code for that ID.

    Warranty

    This SECO-LARM product is warranted against defects in material and workmanship for one (1) year from the date of sale to the original consumer customer. SECO-LARM's obligation is limited to repair or replacement of defective parts, transportation prepaid to SECO-LARM. Void if damage results from acts of God, misuse/abuse, neglect, unauthorized repair/alteration, or improper installation.

    Also available: PR-K1K1-AQ proximity key fobs and PR-K1S1-A proximity cards (sold in packs of 10).