Specifications for the SECO-LARM SK-1123-SDQ Vandal Resistant Outdoor Access Control Keypad (1,100 users, dual output).
Specifications for the SECO-LARM SK-1123-SDQ Vandal Resistant Outdoor Access Control Keypad — a weatherproof (IP66), 1,100-user, dual-output keypad with anti-tailgating, duress-code, real-time clock, and mantrap features, all programmable directly from the keypad.
The SK-1123-SDQ supports 1,100 users across two Form C relay outputs (1,000 users on Output #1, 100 on Output #2), with 4~8 digit codes. Every feature — including duress codes, temporary visitor codes, scheduled access, and anti-tailgating — is programmed directly at the keypad, with no external programmer required.
| Operating voltage | 12~24 VDC/VAC |
| Current draw — standby (12VDC) | 66mA |
| Current draw — keypress | 93mA |
| Current draw — Output 1 active | 99mA |
| Current draw — Output 1 & 2 active | 126mA |
| Total max current draw | 160mA |
| Output #1 | Form C, 1A@30VDC |
| Output #2 | Form C, 1A@30VDC |
| Key Active output | 100mA@24VDC |
| Duress output | 100mA@24VDC |
| Interlock output | 100mA@24VDC |
| Tamper output | 50mA@24VDC |
| Egress input | N.O. Ground |
| Door sensor input | N.C. Ground |
| Door inhibit input | N.O. Ground |
| Operating temperature | -4°~158°F (-20°~70°C) |
| Operating humidity | 5~95% non-condensing |
| Dimensions (incl. back box) | 4¹⁵⁄₁₆"x3⅛"x2¹⁄₁₆" (125x79x52mm) |
| Weight | 1-lb 2-oz (520g) |
| Status | Sounds | Amber LED (Center) |
|---|---|---|
| In programming mode | – | Steady ON |
| Successful key entry | 1 beep | 1 flash |
| Successful code/card entry | 2 beeps | 2 flashes |
| Unsuccessful code/card entry | 5 beeps | 5 flashes |
| Power up delay | Continuous beeping | Continuous flashing |
| Output relay activation | 1-sec long beep | – |
| In standby mode | – | 1 flash/sec |
| System refresh mode | 2 beeps | Fast flashing for 2.5 min |
| Card/code already stored | 1 long beep | – |
| Real-time clock stopped after power loss | Continuous 3 fast beeps every 5 seconds | – |
The right LED (Green/Red) indicates Output #1 status: green when activated, red when inhibited (inhibit mode paused). The left LED (Red) indicates Output #2 activation status.