August 31, 2026 4 min read
Installation manual for the SECO-LARM SD-996C-NUQ Universal Door Strike — a field-configurable electric strike for wood, aluminum, or metal door frames.
Installation manual for the SECO-LARM SD-996C-NUQ Universal Door Strike — a field-configurable electric strike for wood, aluminum, or metal door frames, with an optional trim plate.
The SD-996C-NUQ can be used with virtually any cylindrical-locking system and can be configured for wood, aluminum, or metal doors. It includes three different ANSI-sized faceplates to match the door frame type, and is easily field-configurable for fail-safe or fail-secure operation.
| Operating Voltage | 12 or 24 VDC ±15% |
| Current Draw (12VDC) | 280mA |
| Current Draw (24VDC) | 140mA |
| Operating Temp | 14°–113°F (-10°–45°C) |
| Operating Humidity | 85% ±15% |
Note: Not all parts will be used in every installation.
Note: The electric strike must be installed so it does not impair the operation of any emergency exit or panic-mounted hardware on the door.
If the cut hole is too large or jagged, mount the trim plate over it to improve appearance. Screw the trim plate into the mounting holes at the top and bottom of the door strike using the included trim plate screws. Trim plate is optional and only needed to cover gaps.
Used when the hollow door frame material is unsuitable for direct mounting (commonly for retrofitting):
Factory default is Fail-Safe.
Recommended: short brushed aluminum SD-996RA-11Q faceplate with mounting tabs.
| Measurement | Value |
|---|---|
| A | 3⅓" (78mm) |
| B | ⅛" (17mm) |
| C | ₛ" (9mm) |
| D (faceplate thickness) | ⅛" (3mm) |
| E | 1&frac32;" (39mm) |
| G | 1" (25mm) |
Recommended: short steel SD-996SS-11Q faceplate. If cutting a hole in the frame, mounting tabs may be needed for reinforcement.
| Measurement | Value |
|---|---|
| A | 3⅓" (78mm) |
| B | ⅛" (17mm) |
| C | ₛ" (9mm) |
| D (faceplate thickness) | ⅛" (3mm) |
| E | 1&frac32;" (39mm) |
Recommended: long brushed aluminum SD-996RA-31Q faceplate (uses wood screws).
| Measurement | Value |
|---|---|
| A | 3⅓" (78mm) |
| B | ⅛" (17mm) |
| C | ⅝6" (11mm) |
| D (faceplate thickness) | ⅛" (3mm) |
| E | 1&frac32;" (39mm) |
| F | ⅝6" (33mm) |
| Problem | Checks / Solutions |
|---|---|
| Electric strike does not activate | Dismount and check the four wires are connected properly; ensure wires connect to a 12 or 24VDC source; use a multimeter to test voltage/amperage (use heavier gauge wire or increase power supply output if insufficient); confirm the activation device (keypad/push-button) is working. |
| Door does not open when the strike is activated | Check that the door latch operates properly (replace if necessary); the strike position may need adjustment by moving it or adding washers/shims. |
| Strike makes a buzzing sound | Use a DC power supply instead of AC. |
This SECO-LARM product is warranted against defects in material and workmanship for three (3) years from date of sale to the original customer, under normal service. SECO-LARM's obligation is limited to repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. Warranty is void for damage from acts of God, misuse or abuse, neglect, unauthorized repair or alteration, improper/abnormal usage, or faulty installation.
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Phone: (949) 261-2999 | (800) 662-0800
Email: sales@seco-larm.com
Website: www.seco-larm.com
Sign up to get the latest on sales, new releases and more …