  • SECO-LARM ENFORCER SD-997A/B Electric Deadbolt — Installation Manual

    August 31, 2026 4 min read

    Installation manual for SECO-LARM's ENFORCER SD-997A (fail-secure) and SD-997B (fail-safe) concealed electric deadbolts for hollow metal door frames.

    Full text manual (for reference)

    Installation manual for the SECO-LARM ENFORCER SD-997A (fail-secure) and SD-997B (fail-safe) Electric Deadbolts — concealed electric deadbolts designed for hollow metal door frames.

    Overview

    The SD-997A/B add concealed deadbolt security to most wood or hollow metal doors with electrical operation. They're designed for hollow metal door frames (the door itself can be wood or metal) and are best suited for office-type applications. The bolt is stainless steel, 5/8" diameter with a 5/8" throw.

    Model Differences

    • SD-997A — Fail-Secure: locks if power is lost. Includes a separate manual lock/unlock key cylinder for manual operation during a power outage.
    • SD-997B — Fail-Safe: unlocks if power is lost.

    Specifications

    Spec SD-997A SD-997B
    Operation Fail-Secure Fail-Safe
    Current Draw Standby: 320mA · Activated: 880mA Standby: 360mA · Activated: 900mA
    Status Sensor SPDT, 500mA @ 12VDC (N.O./C./N.C.)
    Operating Voltage 12VDC
    Adjustable Delay Timer 0, 3, 5, 9 sec 0, 2.5, 5, 9 sec
    Weight 2lbs 5oz (1kg) 1lb 13oz (0.82kg)

    Features

    • Door open/close monitor (NO/C/NC)
    • Adjustable door lock delay timer
    • Magnetic switch senses door position for positive locking
    • Attempts to lock multiple times if the door isn't closed properly, to prevent the solenoid from burning out
    • Powered by a solenoid; stainless steel construction for strength and long life
    • Can be used with an optional digital keypad (e.g. SECO-LARM SK-983A / SK-983A100) for high security without a key
    • Shallow design for use with most metal door jambs

    Included Parts

    • Lock body x1, Strike Plate x1
    • Oval cylinder plate x2, Faceplate x1
    • Mounting tabs (large) x2, mounting tabs (small) x2
    • 6-pin connector x1, 3-pin connector x1
    • Templates x4, mounting screws, keys x3
    • Manual lock/unlock cylinder
    • SD-997A only: two drilling templates (key and manual knob), separate 3-pin connector for alarm panel/annunciator connection

    Installation

    1. Determine the mounting location. Can be mounted opposite the door hinges, on the header, or on top of the door away from the hinges. Avoid mounting at the bottom due to dirt/dust buildup risk. For vertical mounting of SD-997B only, wires must come out the top of the unit.
    2. Tape the templates to the door frame and door — align so the deadbolt on the lock body template is centered on the deadbolt hole of the strike plate template, leaving room at the ends for mounting tabs.
    3. Door frame cut: cut out the space for the lock body, test fit, then drill two 5mm screw holes per the template.
    4. Door cut and mount:
      • Wood doors: chisel a 3mm-deep space, drill the magnet hole (12mm wide x 6mm deep), mount the strike plate with 4 wood screws, and drill the deadbolt hole to 16mm (5/8") depth.
      • Hollow metal doors: cut the space for the strike plate, drill two screw holes per mounting tab, and fix the mounting tabs and strike plate with screws.
    5. Door jamb cut and mount: cut the space for the lock body face, drill one 5mm hole per mounting tab, and fix the tabs. SD-997A only: insert the lock/unlock cylinder.
    6. Connect and insulate the wires (see Wiring section below), pushing all wires into the door frame (cut away part of the dust catcher or drywall carefully if space is tight).
    7. Set the door lock delay timer — this is the time it takes for the deadbolt to automatically re-lock after the door closes. (Note: the deadbolt automatically relocks 4 seconds after an optional external push/egress button is pressed, if the door wasn't opened.)
    8. SD-997A only — manual lock/unlock cylinder: insert the cylinder and secure with the provided long screw. Turning the key or manual knob unlocks the SD-997A manually.
    9. Attach the faceplate over the lock body face using screws to fix both to the mounting tabs.

    Wiring

    • Red — Power input (+)
    • Brown — Power input (–)
    • Orange — Control wire (ground to release bolt)
    • Green — Door monitor, COM
    • Yellow — Door monitor, N.C. (active when door closed)
    • Blue — Door monitor, N.O. (active when door open)

    SD-997A only, for alarm panel connection: Purple wire — active if door is locked (N.C.); Gray wire — manual lock/unlock (COM); Black wire — active if door is unlocked (N.O.).

    Important: Correct polarity of the red and brown wires is critical — reversing polarity will burn out the solenoid.

    Troubleshooting

    Problem Possible Cause Solution
    Deadbolt doesn't activate when door closes Sensor in lock body too far from magnet in strike plate Adjust the strike plate, lock body position, or add shims
    Deadbolt activates but doesn't lock the door Deadbolt not properly entering the deadbolt hole Reposition strike plate; if hitting the bottom of a wooden door's hole, drill deeper
    Need to reset unit Ground the orange wire momentarily
    Other problems Substitute a known-working unit in the same door frame to isolate the fault; replace if defective

    Warranty

    ENFORCER locks are warranted against defects in material and workmanship for one (1) year from date of sale to the original customer. SECO-LARM's obligation is limited to repair or replacement of defective parts, transportation prepaid to SECO-LARM.

    SECO-LARM U.S.A., Inc. — 16842 Millikan Avenue, Irvine, CA 92606. Tel: 800-662-0800 / 949-261-2999. Email: sales@seco-larm.com.