    Complete instruction manual for the SECO-LARM Enforcer SA-027HQ 365-Day Annual Timer — dual-relay programmable timer for security, access, and lighting control.

    Full text manual (for reference)

    Complete instruction manual for the SECO-LARM Enforcer SA-027HQ 365-Day Annual Timer — a dual-relay programmable timer for security, access control, lighting, and environmental control applications.

    Overview & Features

    • Two N.O. or N.C. Form C relays, rated 10A @ 14VDC
    • Each relay supports 50 programmable events — 100 total, settable weekly, daily, or hourly across an entire year
    • 10 programmable holidays disable the timer for a single day or the same day every year
    • Password protection can be turned ON or OFF
    • One egress input per relay (2 total)
    • Block programming repeats events across consecutive days
    • First-person-in function interrupts normal timer operation via an N.O. ground switch
    • Event outputs: disable, ON, OFF, shunt, or momentary (1–99 seconds)
    • Tandem mode runs both relays simultaneously
    • EEPROM memory retains programming through power failure; built-in clock backup battery and backup battery charger
    • Compensates for leap years; supports Standard or Daylight Saving Time
    • Alphanumeric backlit LCD display

    Specifications

    Spec Value
    Input voltage 12~24 VDC/VAC
    Number of relays 2
    Relay rating 10A @ 14VDC
    Current draw 100mA
    Number of programmable events 50 per relay, 100 total
    Number of programmable holidays 10
    Battery charging current 90mA
    Security code 4-digit numeric, ON/OFF

    Installation

    1. Find a location where the LCD display is easily seen and the buttons are accessible; mark it.
    2. Open the case and connect the wires.
    3. Connect a 12/24 VDC/VAC power supply to the power input terminals marked (+) and (-).
    4. Connect the battery backup to the backup battery input terminals marked (+) and (-). For best charging results, power input should not be lower than 17VDC or 12VAC.
    5. Remove the paper battery protector from the onboard clock backup battery — if not removed, the backup battery will fail to function.
    6. Connect the devices being controlled to the outputs of one or two relays. Note: for DC-powered electric/electromagnetic locks, connect a 1N4004 diode in parallel with the power supply, as close to the lock as possible, to prevent interference and lock-related damage to the timer. Not required for AC-powered locks.
    7. Close the case and mount the unit.

    Function Buttons

    Button Function
    SET Enters the main menu, backs out of a submenu
    ENTER Enters a submenu, accepts the current value above the cursor
    UP Changes the menu selection or the value above the cursor
    DOWN Changes the menu selection or the value above the cursor

    Programming Key Reference

    • BK — Block Coding   HOL — Holiday
    • ON — Relay switches on   OFF — Relay switches off   DIS — Relay disabled   PL — Relay pulses for a set number of seconds
    • DS — Daylight Saving Time   ST — Standard Time
    • R1 / R2 — Relay 1 / Relay 2
    • Days: MO, TU, WE, TH, FR, SA, SU

    Programming Events, Holidays & Block Coding

    Press SET repeatedly to cycle through menu options: SET TIME, SET EVNT, SET HOL, CLR MEMO, SET BK, and SET CODE. Press ENTER to confirm a selection and enter that submenu.

    • Setting Time and Date: Press SET until "ENTER TO SET TIME" appears, then ENTER. Use UP/DOWN to set month, date, year, day of week, hour, and minute (24-hour format). Press ENTER to confirm each field.
    • Programming Events: Press SET until "ENTER TO SET EVNT" appears, then ENTER. Use UP/DOWN to set the event number, relay, operating mode, and scheduled day/time. Example: 01R1PL45 WE 12:45 = Event #1, Relay #1, pulse 45 seconds, Wednesday only, occurs at 12:45.
    • Programming Holidays: Press SET until "ENTER TO SET HOL" appears, then ENTER. Use UP/DOWN to set the holiday number and date. Set the year to "XX" to repeat that holiday every year.
    • Clearing Memory: Press SET until "ENTER TO CLR MEMO" appears, ENTER to confirm, then UP to clear.
    • Block Programming & Time Format: Press SET until "ENTER TO SET BK" appears, then ENTER. Use UP/DOWN to set the first and last day of a consecutive-day range, and to toggle between Daylight Saving Time (DS) and Standard Time (ST). The unit follows U.S. DST rules: begins 2:00 a.m. on the 2nd Sunday of March, ends 2:00 a.m. on the 1st Sunday of November.

    Password Protection

    • Press SET until "ENTER TO SET CODE" appears, then ENTER. Choose YES/NO to enable/disable password protection.
    • Factory default password is 0000.
    • To change: enter the old code, then the new 4-digit code, and confirm.
    • If enabled, the password must be entered every time programming mode is accessed.

    Password Reset

    1. Disconnect power (and remove backup batteries if installed).
    2. Within 30 seconds of reconnecting power, press and hold all four buttons (UP, DOWN, SET, ENTER) together for about 5 seconds.
    3. "PASSWORD RESET" displays for 1 second, then "NEW PSWD 0000" for 1 second, then "ENTER PASSWORD".
    4. The password resets to factory default 0000. No other programming is affected.
    5. Enter a new password within 1 minute, or the unit exits password programming automatically.

    Tandem Relay Operation

    Setting jumper JP01 to "ON" causes both relays to activate together whenever an event is programmed for either Relay #1 or Relay #2 (factory default is OFF/no tandem output).

    Wiring

    • Power input: 12~24 VAC/VDC
    • Backup battery input: 17~24VDC or 12~24VAC ONLY — an unregulated 12VDC adapter (ST-1212-U0.5A) is acceptable.
    • First-person-in inputs (#1, #2): connect to N.O. ground switch — suspends timer operation while activated; once deactivated, the timer resumes the last programmed function.
    • Relay outputs (#1, #2): N.O. / COM / N.C. terminals connect to controlled devices.
    • Egress inputs (#1, #2): connect to N.O. ground switch.

    Warranty

    SECO-LARM warrants this product against defects in material and workmanship for one (1) year from the date of sale to the original consumer, limited to repair or replacement of defective parts (transportation prepaid to SECO-LARM). Void if damage results from acts of God, misuse, abuse, neglect, unauthorized repair/alteration, improper usage, or faulty installation.