SECO-LARM ENFORCER E-964-Q Series Quad-Photobeam Detectors — long-range outdoor/indoor perimeter protection with 4 selectable beam frequencies.
The SECO-LARM ENFORCER E-964-Q Series Quad-Photobeam Detectors are long-range outdoor/indoor perimeter protection sensors. Four selectable beam frequencies eliminate crosstalk when multiple units are installed nearby, and the sensor only triggers when all 4 beams are simultaneously broken — minimizing false alarms from animals, falling leaves, rain, snow, or fog.
| Model | Max Range (Outdoor) | Max Range (Indoor) |
|---|---|---|
| E-964-Q165Q | 165 ft. (50m) | 330 ft. (100m) |
| E-964-Q330Q | 330 ft. (100m) | 660 ft. (200m) |
| E-964-Q495Q | 495 ft. (150m) | 990 ft. (300m) |
| E-964-Q660Q | 660 ft. (200m) | 1320 ft. (400m) |
| Input voltage | 12~24 VAC/VDC (non-polarity) |
| Detection method | All 4 beams simultaneously broken |
| Selectable beam frequencies | Four (4) channels |
| Alarm output | Form "C" relay COM/N.O./N.C., 1A @ 125VAC/24VDC |
| Tamper output (Tx & Rx) | NC switch, 1A @ 120VAC |
| Environmental output | Selectable N.O. or N.C., 1A @ 125VAC/24VDC |
| Laser wavelength / output power | 650nm / ≤5mW |
| Alignment angle | Horizontal: ±90° Vertical: ±15° |
| Operating temperature | -13°F ~ 131°F (-25°C ~ 55°C) |
| Weight | 5.7 lbs. (2.6kg) |
| Ingress protection | IP55 |
| Dimensions | 15-1/4" x 4-7/16" x 4-11/32" (387 x 113 x 110mm) |
| Voltage Output | <1.6V | 1.6~2.0V | 2.0~2.4V | 2.4~2.8V | 2.8~3.2V | >3.2V |
|---|---|---|---|---|---|---|
| Alignment Quality | No Signal | Bad | Poor | OK | Good | Strongest |
Where more than one E-964-Q unit is installed nearby (long-distance series, two-layer/stacked, perimeter, or single-pair multi-layer configurations), assign each transmitter/receiver pair to a different channel (Ch1–Ch4) to avoid crosstalk between adjacent units.
| Issue | Solution |
|---|---|
| Transmitter LED not lit | Make sure the input power to the transmitter is 12 to 24 VAC/VDC. |
| Receiver LED does not light when interrupted | Check the input power to the receiver is 12 to 24 VAC/VDC. |
| Beams interrupted and LED lights, but alarm doesn't trigger | Check the continuity of the wiring from the receiver to the alarm. |
| Signal LED continuously lit | Clear obstacles between transmitter and receiver; clean the lenses of both units. |
| Alarm trigger becomes erratic in bad weather | Check overall system installation; realign the lenses. |
| Frequent false alarm triggers | Adjust the response (delay) time; change the location of transmitter and receiver. |
Warranted against defects in material and workmanship for three (3) years from the original consumer purchase date. SECO-LARM's obligation is limited to repair or replacement of defective parts if the unit is returned, transportation prepaid, to SECO-LARM. Void if damage is caused by acts of God, misuse, abuse, neglect, improper repair/alteration, or faulty installation.