    Installation manual for the SECO-LARM ENFORCER Curtain/Barrier Sensors (E-9611 through E-9680) covering the full 2- to 10-beam product line.

    Full text manual (for reference)

    Installation manual for the SECO-LARM ENFORCER Curtain/Barrier Sensors (E-9611, E-9622, E-9644, E-9660, E-9680) — photoelectric beam sensors for windows, doorways, skylights, fence tops, and perimeter security applications.

    Overview

    The ENFORCER Curtain/Barrier Sensor line offers 2, 4, 6, 8, or 10 separate photoelectric beam sensors in a slim-line (7/8" x 15/16") aluminum housing. They can be programmed to trigger on the simultaneous breaking of any single beam or two adjacent beams, and are suitable for both indoor and outdoor perimeter security use.

    Available Models

    Model Beams Length
    E-9611-2x25 2 11.25" (29cm)
    E-9622-4x25 4 22.5" (57cm)
    E-9644-6x25 6 44.5" (113cm)
    E-9660-8B25 8 60.1" (153cm)
    E-9680-10B25 10 79" (201cm)

    The 2, 4, and 6-beam models are also available in white.

    Features

    • Multi-frequency design to reduce interference between multiple units
    • Install on windows, doorways, skylights, fence tops, and other space-limited locations
    • Suitable for indoor and outdoor* perimeter security (see "Choosing a Location" below)
    • 2, 4, 6, 8, or 10 separate photoelectric beam sensors, programmable to trigger on single or 2-adjacent-beam break
    • Rugged aluminum construction
    • Anti-tamper circuit for use when power is cut or an end cap is removed
    • No synchronizing wires required
    • N.O./N.C. relay output; LED alignment indicator
    • L-brackets and mounting hardware included

    Choosing a Location

    When used outdoors, place the curtain sensor under a roof or shelter to reduce false alarms from rain or snow. To prevent erratic operation or false alarms:

    • Do not mount near trees, bushes, or other leafy vegetation — wind can blow leaves/debris into the beams
    • Do not mount where roof runoff water might break the beam; if unavoidable, the sensor must be sheltered
    • Do not mount near reflective surfaces, which can prevent proper operation
    • Do not mount where the transmitter/receiver could be splashed by water or mud
    • Do not mount where the unit could be suddenly exposed to bright light (floodlight, headlights)
    • Do not let sunlight or any direct light beam shine directly on the sensor; if unavoidable, orient so the transmitter (not the receiver) faces the sun
    • Do not mount where animals or other objects could accidentally break the beams

    Mounting the Curtain Sensor

    1. Find a suitable location. The transmitter and receiver can be mounted at any angle as long as they're parallel and directly facing each other, with wires exiting the same end of both units.
    2. If using multiple curtain sensors, set each to a different frequency (see Selectable 3-Channel Beam Frequency below).
    3. The transmitter and receiver must not be separated by more than 50 ft. indoors, 25 ft. outdoors.
    4. Mount so surface wires do not exit from above the units (to prevent water intrusion); use silicone if this is unavoidable.
    5. Remove the end cap covers and pull the tamper buttons out, then mark mounting hole locations on the wall.
    6. Connect the wires before permanently mounting the units (see Wiring below).

    Running & Connecting the Wires

    Run four wires (2 x power, 2 x alarm signal) from the alarm control panel to the receiver. Shielded cable is strongly suggested. Two power wires must also be run to the transmitter (or run six wires to the receiver if connecting the transmitter's power through the receiver: 2 power source + 2 alarm signal + 2 to transmitter).

    Voltage Gauge Max Length
    12VDC AWG 22 1800 ft (550m)
    12VDC AWG 20 2600 ft (800m)
    24VDC AWG 22 2600 ft (800m)
    24VDC AWG 20 3900 ft (1200m)

    If burying wires, run them through electrical conduit; shielded cable is strongly suggested. If running wires along a wall, use armored cable. Note: unused terminal screws should be tightened; grounding may be necessary depending on location.

    Programming (Transmitter & Receiver Jumpers)

    Each transmitter/receiver has a jumper labeled "JMP1" controlling LED behavior and "JMP2" controlling the number of beams required to trigger the receiver (1 beam = triggers if any single beam is interrupted; 2 beams = triggers only if 2 adjacent beams are interrupted simultaneously). A third jumper, "JMP3," selects one of three beam frequencies (A, B, or C) to avoid interference between multiple units installed nearby — both the transmitter and receiver of a pair must be set to matching frequencies. If a different frequency is selected, cycle power on both units after changing the jumper.

    Connecting Multiple Curtain Sensors

    Several units can be connected together in parallel to the same power supply output and alarm input of an alarm control panel, either as a standard setup (shared alarm channel), dual sensors on separate alarm channels, or in-line on a single alarm channel.

    Testing & Final Mounting

    1. Temporarily mount the transmitter and receiver where expected so position can still be adjusted.
    2. Connect the transmitter and receiver.
    3. Once powered, test by breaking two adjacent beams or any single beam (depending on programming).
    4. The curtain sensor also has red LEDs usable for testing purposes.
    5. After testing and aligning, permanently mount the unit.
    6. Test again after final mounting.

    Removing the Lens Caps (Outdoor Use Only)

    For best results outdoors, remove the transmitter lens caps only — do not remove the receiver lens caps. Slide out the transmitter's circuit board, carefully pull off the lens caps (4 for the E-9611-2x25, 8 for the E-9622-4x25, 12 for the E-9644-6x25, 16 for the E-9660-8B25, 20 for the E-9680-10B25), then slide the circuit board back in.

    Tamper Protection

    The receiver and transmitter each have a tamper switch on one end to protect against unauthorized opening. There is no separate tamper output to the alarm control panel — instead, the alarm output is triggered if the end cap cover with the tamper button is removed, if the transmitter/receiver is moved out of alignment, or if power is disconnected.

    Troubleshooting

    Problem Possible Cause Possible Solution
    Transmitter LED never turns on Power not connected, or power wires cut Test power/ground wire with a voltage meter
    Transmitter jumper "JMP1" is in the open position Change the programming, or leave jumper open if no LED is desired
    Receiver LED never turns on Power not connected, or power wires cut Test power/ground wire with a voltage meter
    Receiver LED does not turn on unless triggered Receiver jumper "JMP1" is in the open position Change the programming as needed
    Receiver LED flashes constantly Transmitter and receiver out of alignment Re-align the transmitter and receiver
    Does not trigger when beam is broken Mounted too close to a shiny surface causing multi-angle reflection Remount or repaint the surface to reduce reflection
    Receiver continuously triggers the alarm Out of alignment, or tamper button cover not seated correctly Re-align units; check tamper button/cover
    False alarm Interference from other sensors, wind-blown leaves, rain, or other outdoor interference Reposition sensors, cut back vegetation, mount under shelter

    Specifications

    Standby current (12~24VDC) 80–110mA depending on model
    Active current (12~24VDC) 60–100mA depending on model
    Response time 0.5–20ms up to 0.5–70ms depending on model
    Maximum range Indoor: 50 ft (16m); Outdoor: 25 ft (8m)
    Detection method Simultaneous break of 2 adjacent beams, or any single beam (programmable)
    Output N.O./N.C. relay output, 1A @ 12~24VDC
    Operating temperature -49° to 131°F (-45° to 55°C)
    Attenuation LED On = powered/aligned properly; Flashing = beam broken/unaligned; Off = no power (depending on programming)
    Enclosure / Case IP65 / Al alloy
    Mounting bracket Included

    Warranty

    This SECO-LARM product is warranted against defects in material and workmanship in normal service for one (1) year from the date of sale to the original consumer customer. SECO-LARM's obligation is limited to repair or replacement of any defective part if returned, transportation prepaid, to SECO-LARM. Void if damage results from acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation.

    SECO-LARM® U.S.A., Inc. — 16842 Millikan Avenue, Irvine, CA 92606 | Tel: 800-662-0800 / 949-261-2999 | Fax: 949-261-7326 | www.seco-larm.com