  • Qubino Mini Dimmer (ZMNHHD3) — Installation Instructions

    September 08, 2026 3 min read

    Quick installation instructions for the Qubino Mini Dimmer (ZMNHHD3): 2/3-wire wiring, safety warnings, Z-Wave inclusion/exclusion (including S2 security), and technical specifications.

    Full text manual (for reference)

    Quick installation guide for the Qubino Mini Dimmer (model QUZMNHHD3 and related ZMNHH-series variants) — a MOSFET-switching light dimming module compatible with 2- or 3-wire connections (no neutral wire required). Supports low-voltage halogen lamps with electronic transformers, dimmable CFLs, and dimmable LED bulbs. Measures power consumption and can act as a normal switch with non-dimmable lights.

    Package Contents

    • Mini Dimmer device
    • Installation Manual
    • S2 packaging label (contains the security PIN code)

    Safety Warnings

    • Danger of electrocution! Installation requires a great degree of skill and may be performed only by a licensed, qualified electrician. Even when the device is off, voltage may still be present in its terminals.
    • Disconnect electrical power at the main fuse or circuit breaker before installation/maintenance. Confirm no voltage remains in the wiring before proceeding.
    • Take extra precautions against accidentally turning the device on during installation.
    • Do not connect to loads exceeding recommended values — connect exactly per the wiring diagram.
    • Place the antenna as far as possible from metal elements; do not shorten the antenna.

    Z-Wave Inclusion (Adding to Network)

    Auto-Inclusion

    1. Enable inclusion mode on your Z-Wave gateway (hub)
    2. Connect the device to the power supply
    3. Auto-inclusion initiates within 5 seconds and the device registers automatically to your network

    Manual Inclusion

    1. Enable add/remove mode on your Z-Wave gateway (hub)
    2. Connect the device to the power supply
    3. Toggle the I1-terminal switch 3 times within 3 seconds (3 pushes on a push-button, or 3 On/Off presses on a normal switch), or hold the S (Service) button 2–6 seconds if on 24V SELV power
    4. A new dimming device (multilevel switch) appears on your dashboard
    5. Inclusion via the I1 switch is not time-limited

    Note: For S2 Security inclusion, a dialog will prompt for a 5-digit PIN printed on the module label and the packaging label. Keep this PIN — it cannot be retrieved once lost.

    Z-Wave Exclusion / Reset

    Exclusion

    1. Connect the device to the power supply, ensure it's within range of your Z-Wave gateway or handheld remote
    2. Enable exclusion mode on your gateway
    3. Toggle the I1 switch 3 times within 3 seconds, or hold the S (Service) button 2–6 seconds on 24V SELV power
    4. Exclusion via the I1 switch is not time-limited; custom configuration parameters are NOT erased

    Factory Reset

    1. Connect the device to the power supply
    2. Within the first minute, toggle the I1 switch 5 times within 3 seconds, or hold the S (Service) button at least 6 seconds on 24V SELV power

    Resetting returns all custom parameters to default and deletes the node ID. Use only when the main gateway/hub is missing or inoperable.

    Technical Specifications

    Power supply 110–240 VAC ±10%, 50/60Hz (24–30VDC)
    Rated load current (AC output) 0.85A / 240VAC
    Output circuit power (resistive load) 200W* (240VAC) / 90W (110VAC)
    Power measurement accuracy 2-wire: ±10%; 3-wire: ±2%
    Operation temperature -10 ~ +40°C
    Distance (Z-Wave range) Up to 30m indoors (depending on building materials)
    Dimensions (package) 38 × 33.5 × 15.5mm (86 × 74 × 43mm packaged)
    Weight (with package) 24g (50g)
    Electricity consumption 0.4W
    For installation in boxes Ø ≥ 60mm or 2M, depth ≥ 60mm
    Switching MOSFET (Trailing edge)

    Supported Dimmable Loads

    Load Type Max Rating
    Conventional incandescent and halogen lights 200W (240VAC) / 90W (110VAC)
    LED bulb, CFL, low-voltage halogen bulbs with electronic transformer 150W (240VAC) / 70W (110VAC)
    Low-voltage halogen bulbs with conventional transformer 150W (240VAC) / 70W (110VAC)

    Important Notes

    • The S (Service) button must NOT be used when the device is connected to 110–240V power supply.
    • The 24–30VDC connection can only be used to add, remove, or reset the device with the S button in a 3-wire installation.
    • In a 2-wire installation, if the connected load starts flickering, use a Bypass accessory.
    • When overload is detected, the device automatically switches off. Check the load matches specifications and connections match the diagram. Power-cycle the device to restore normal dimmer operation.

    Model naming: ZMNHHXY — X, Y values define product version per region/frequency. See Qubino's online catalogue for the exact regional variant.