September 08, 2026 7 min read
Extended user manual for the Qubino Flush 2 Relay (ZMNHBD3): use cases, associations, full configuration parameter reference, and technical specifications.
Extended user manual for the Qubino Flush 2 Relay (model QUZMNHBD3 and related ZMNHBD-series variants). This module remotely controls up to two electrical devices — door locks, door openers, small appliances, fans, or lights. It measures power consumption of both connected devices and can be paired with an optional digital temperature sensor to build complex, temperature-driven scenes. It also acts as a Z-Wave repeater to extend network range and stability.
| Ordering Code (Model) | Power Supply Frequency | Z-Wave Frequency |
|---|---|---|
| ZMNHBD1 | 50/60 Hz | 868.4 MHz |
| ZMNHBD2 | 50/60 Hz | 921.4 MHz |
| ZMNHBD3 | 50/60 Hz | 908.4 MHz |
| ZMNHBD4 | 50/60 Hz | 869.0 MHz |
| ZMNHBD5 | 50/60 Hz | 916.0 MHz |
| ZMNHBD6 | 50/60 Hz | 868.4 MHz |
| ZMNHBD7 | 50/60 Hz | 919.8 MHz |
| ZMNHBD8 | 50/60 Hz | 865.2 MHz |
| ZMNHBD9 | 50/60 Hz | 922.5 MHz |
| ZMNHBDA | 50/60 Hz | 919.7 / 921.7 / 923.7 MHz |
| ZMNHBDB | 50/60 Hz | 868.1 MHz |
| ZMNHBDC | 50/60 Hz | 868.1 MHz |
| ZMNHBDD | 50/60 Hz | 919.8 MHz |
| ZMNHBDE | 50/60 Hz | 920.9 MHz |
For loads other than resistive, pay attention to the value of cos φ and apply loads lower than the rated load if necessary. Max current for cos φ=0.4 is 3A at 250VAC, 3A at 24VDC (L/R=7ms). Max power limit is automatically enforced by software — if max power is exceeded for more than 5 seconds, the output turns off until the module is next restarted, and an "Over-load detected" event is sent to the gateway.
Note: the device can be automatically added to a Z-Wave network during the first 2 minutes after being connected to power.
Important: make sure the device is excluded from your network before connecting the temperature sensor. Switch off the power supply, connect the sensor, and re-include the device to your network.
Resetting returns all custom parameters to default values and deletes the node ID. Use this reset procedure only when the main gateway (hub) is missing or otherwise inoperable.
Associations enable direct communication between the Flush 2 Relay and other devices on your Z-Wave network, without needing your primary gateway.
Each endpoint has its own Lifeline group (0 nodes) plus Basic on/off, Switch binary report, and Power meter report groups (up to 16 nodes each) scoped to that channel's load.
Lifeline group (0 nodes) plus a Multilevel sensor report group (up to 16 nodes) for the optional temperature sensor.
| Power supply | 110–240 VAC ±10% 50/60Hz, (24–30VDC) |
| Rated load current (AC/DC output, resistive) | 2 × 4A / 240VAC / 30VDC |
| Output circuit power (resistive load) | 2 × 920W (240VAC) / 2 × 96W (24VDC) / 2 × 440W (110VAC) |
| Conventional incandescent/halogen lights | 2 × 920W (240VAC) |
| LED bulb | 0.5A per channel |
| LVH Electronic transformer | 2.4A per channel |
| Electric motor | Apply cos φ; max current for cos φ=0.4 is 2A at 250VAC (RC snubber recommended for inductive loads) |
| Power measurement accuracy | P=0–200W ±2W; P>200W ±3% |
| Digital temperature sensor range | -25 ~ +80°C (-13 ~ 176°F), resolution 0.1°C |
| Operation temperature | -10 ~ +40°C (14 ~ 104°F) |
| Z-Wave operation range | Up to 30m indoors (98 ft) |
| Dimensions (package) | 41.8 × 36.8 × 16.9mm (79 × 52 × 22mm packaged) |
| Weight (with package) | 28g (34g) |
| Electricity consumption | 0.4W |
| For installation in boxes | Ø ≥ 60mm (2.36in) or 2M, depth ≥ 60mm |
| Switching | Relay (2×) |
| Z-Wave Repeater | Yes |
| Capacitance | 0.1μF |
| Voltage | 630VDC / 275VAC |
| Resistance | 47Ω |
| Power Rating | 1/2 W |
Suggested part: KEMET P409CE104M275AH470. RC snubber must be connected in parallel to the load.
Role Type: ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON | Generic Type: SWITCH_BINARY | Specific Type: POWER_SWITCH_BINARY
Supported command classes: ZWAVEPLUS_INFO_V2, VERSION_V2, MANUFACTURER_SPECIFIC_V2, DEVICE_RESET_LOCALLY_V1, POWERLEVEL_V1, BASIC_V1, SWITCH_ALL_V1, SWITCH_BINARY_V1, METER_V4, SENSOR_MULTILEVEL_V7, MULTI_CHANNEL_V4, ASSOCIATION_V2, MULTI_CHANNEL_ASSOCIATION_V3, ASSOCIATION_GRP_INFO_V2, CONFIGURATION_V1, MARK.
Endpoint 1 (Wall Switch I1) and Endpoint 2 (Wall Switch I2) each expose SWITCH_BINARY device class with ZWAVEPLUS_INFO_V2, VERSION_V2, SWITCH_BINARY_V1, BASIC_V1, SWITCH_ALL_V1, ASSOCIATION_V2, MULTI_CHANNEL_ASSOCIATION_V3, ASSOCIATION_GRP_INFO_V2, and METER_V4 command classes.
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, providing reasonable protection against harmful interference in a residential installation.
Do not dispose of electrical appliances as unsorted municipal waste — use separate collection facilities. Contact your local government for information on available collection systems. When replacing an old appliance with a new one, the retailer is legally obligated to take back the old appliance for disposal free of charge.
Manufacturer: GOAP d.o.o. Nova Gorica, Ulica Klementa Juga 007, 5250 Solkan, Slovenia. Model naming: ZMNHBXY — X, Y values define product version per region/frequency.