  • Qubino Flush Dimmer 0-10V (ZMNHVD3) — Installation & Programming Instructions

    September 08, 2026 4 min read

    Complete installation and programming instructions for the Qubino Flush Dimmer 0-10V (ZMNHVD3) in-wall Z-Wave dimmer module.

    Full text manual (for reference)

    Installation and programming instructions for the Qubino Flush Dimmer 0-10V (ZMNHVD3), a universal in-wall Z-Wave dimmer module with a standard 0-10V output and multi-function input.

    Overview

    The Flush Dimmer 0-10V is a universal dimmer with a standard 0-10V output and a multi-function input. It also measures power consumption and supports connection of an optional digital temperature sensor (sold separately). It supports push-button/momentary switches, toggle switches (default), potentiometers, and 0-10V inputs (requires an external source).

    Package Contents

    • Flush Dimmer 0-10V device
    • Installation Manual

    Safety Warnings

    • Danger of electrocution! Installation of this device requires a great degree of skill and may be performed only by a licensed and qualified electrician. Even when the device is turned off, voltage may still be present in the device's terminals.
    • To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance.
    • Even if the circuit breaker is off, some voltage may remain in the wires — before proceeding with the installation, be sure no voltage is present in the wiring.
    • Take extra precautions to avoid accidentally turning on the device during installation.
    • Connect the device exactly according to the wiring diagram.
    • Place the antenna as far as possible from metal elements to avoid signal interference, and do not shorten the antenna.
    • Do not connect the device to loads exceeding the recommended values. Improper wiring may be dangerous and can result in equipment damage.
    • For overload protection, use fuse F (ESKA 522.504, 50mA, 250V) connected according to the electrical diagram. Fuse installation must conform to IEC 60950-1.

    Installation Steps

    1. Disconnect power at the main fuse or circuit breaker before installation and maintenance.
    2. Verify no voltage is present in the wiring before proceeding.
    3. Connect the device exactly according to the electrical diagram.
    4. Place the antenna as far as possible from metal elements as they may cause signal interference. Do not shorten the antenna.

    Z-Wave Inclusion

    Auto-Inclusion

    1. Enable inclusion mode on your Z-Wave gateway (hub).
    2. Connect the device to the power supply.
    3. Auto-inclusion will be initiated within 5 seconds of connection to the power supply, and the device will automatically enroll in your network.

    Manual Inclusion

    1. Connect the device to the power supply.
    2. Toggle the switch connected to the I1 terminal 3 times within 3 seconds — the device must receive the On/Off signal 3 times, meaning 3 pushes of the push button or 6 flips of the toggle switch.
    3. OR press and hold the S (Service) button for at least 2 seconds.
    4. A new dimming device (multilevel switch) will appear on your dashboard.

    Z-Wave Exclusion

    1. Connect the device to the power supply.
    2. Make sure the device is within direct range of your Z-Wave gateway (hub), or use a hand-held Z-Wave remote to perform exclusion.
    3. Enable exclusion mode on your Z-Wave gateway (hub).
    4. Toggle the switch connected to the I1 terminal 3 times within 3 seconds.
    5. OR press and hold the S (Service) button for 2 to 6 seconds.
    6. The device will be excluded from your network, but any custom configuration parameters will not be erased.

    Factory Reset

    1. Connect the device to the power supply.
    2. Within the first minute after connecting the device to the power supply, toggle the switch connected to the I1 terminal 5 times within 3 seconds.
    3. OR press and hold the S (Service) button for at least 6 seconds.

    Resetting the device returns all custom parameters previously set to their default values, and the owner ID is deleted. Use this reset procedure only when the main gateway (hub) is missing or otherwise inoperable.

    Reconfiguring with a Temperature Sensor

    If you want to add the optional digital temperature sensor after the device has already been included in your network: make sure the device is excluded from your network before connecting the temperature sensor. Switch off the power supply, connect the temperature sensor, and re-include the device to your network.

    Technical Specifications

    Spec Value
    Power supply 12-24VDC (SELV type)
    Max. sinking control voltage -20 / +20VDC
    Max. sourcing control voltage 0-11VDC
    Accuracy <3% FS
    Max. sinking current 2mA
    Max. sourcing current 7mA
    Digital temperature sensor range -50 to +125°C (-58 to 257°F)
    Operating temperature -10 to +40°C (14 to 104°F)
    Intended transportation condition -40 to +70°C (-40 to 158°F)
    Z-Wave operation range Up to 30m (98 ft) indoors
    Dimensions (package) 41.8 x 36.8 x 16.9 mm (device); 79 x 52 x 22 mm (package)
    Weight (with package) 28g (34g) / 0.98oz (1.20oz)
    Electricity consumption 0.5W

    Wiring Diagram Legend

    Terminal Function
    + 12-24VDC power input
    - GND
    AO Analog output, 0-10VDC
    I1 Input for push button/switch/potentiometer or 0-10V
    TS Temperature sensor terminal
    S Service button (used to add or remove the device from the Z-Wave network)

    Important Disclaimer

    Z-Wave wireless communication is not always 100% reliable. This device should not be used in situations where life and/or valuables are solely dependent on its functioning. If the device is not recognized by your gateway (hub) or shows up incorrectly, you may need to manually change the device type and ensure your gateway supports Z-Wave Plus multi-level switch devices. Contact Qubino support (http://qubino.com/support/#email) for help before returning the product.

    Disposal

    Do not dispose of electrical appliances as unsorted municipal waste — use separate collection facilities. Contact your local government for information regarding available collection systems.