September 08, 2026 2 min read
Manual configuration guide for the PulseWorx KPC-8 (8-Button) Controller β step-by-step procedures for setting Network ID, Control Zone, and Links without UPStart software.
Manual Configuration Guide for the PulseWorx KPC-8 Controller (8-Button Controller) β step-by-step procedures for setting up a UPB (Universal Powerline Bus) system entirely by hand, without UPStart software.
The KPC-8 is an 8-Button Controller used in PulseWorx UPB lighting systems. While UPStart PC software can configure a Network ID, Control Zone, and Links automatically, this guide documents the fully manual procedures using only the KPC-8's own pushbuttons.
The Network ID is a unique code shared by all devices in a UPB system so they communicate only with each other and don't interfere with a neighboring UPB system that might share the same ID.
| 1 | Press and hold the 'E' and 'L' pushbuttons to enter Setup Mode β all pushbuttons blink |
| 2 | Press and hold 'G' and 'H' to start learning a new Network ID β 'G'/'H' keep blinking, others turn off |
| 3 | Wait for the controller to finish learning β all pushbuttons turn off |
| 1 | Press and hold 'E' and 'L' to enter Setup Mode |
| 2 | Put all other devices to be taught into their own Setup Mode (see each device's own documentation) |
| 3 | Press and hold 'I' and 'J' until they blink, to teach the new Network ID |
| 4 | Wait for teaching to finish β all devices exit Setup Mode |
Every 8-Button Controller ships from the factory controlling "Zone E" (8 Links). If you have multiple controllers, assign each one a different zone so they don't overlap.
| Zone | Links |
| E | 1β8 |
| F | 9β16 |
| G | 17β24 |
| H | 25β32 |
| I | 33β40 |
| J | 41β48 |
| K | 49β56 |
| L | 57β64 |
Procedure: 1) Press and hold 'E' and 'L' to enter Setup Mode. 2) Triple-tap the pushbutton corresponding to the desired zone β all pushbuttons turn off when the new zone is set.
This procedure can be repeated for any pushbutton on the 8-Button Controller.