September 08, 2026 3 min read
Installation and configuration guide for the PCS PulseWorx OCM Output Control Module, a plug-in UPB load controller with two 8-amp relays.
Installation and configuration guide for the PCS PulseWorx OCM (Output Control Module) — a high-quality plug-in home automation load controller with two 8-amp relays, controlled via digital commands sent over powerline wiring from a remote UPB (Universal Powerline Bus) controller. No additional wiring or RF signals are required.
The OCM receives UPB powerline commands from any UPB-compatible transmitter — PulseWorx Keypad Controllers, Timed Event Controllers, Wall Switches, Interface Modules, approved third-party controllers, and touch screens. Each of the OCM's two channels can be a member of up to 16 scenes, with a pre-set relay state (OPEN or CLOSED) stored per scene.
Once installed, the OCM can be configured either manually or with the UPStart Setup Software (free, available at www.PulseWorx.com). Manual configuration lets you add the OCM into a UPB network, link it to controller buttons, and set preset relay states. The factory default operation is usable out of the box, but configuring with UPStart unlocks the module's full feature set.
To configure a UPB system, place the OCM in SETUP mode by pressing the Program Button five times rapidly — the Status LED blinks continuously Blue while in SETUP mode. Exit SETUP mode by pressing the Program Button twice, or wait five minutes for it to time out automatically.
A manual test feature allows the relays to be closed and opened locally. Press and hold the Program Button for at least 3 seconds to enable TEST mode — the Status LED blinks Magenta. In TEST mode:
To restore factory defaults, place the OCM into SETUP mode, then press the Program Button ten times rapidly. The Status LED blinks red to confirm the reset; press the Program Button twice more to stop the blinking.
| Setting | Default |
|---|---|
| Network ID | 255 |
| Unit ID | 06 |
| Network Password | 1234 |
| Receive Components (Channel #1) | Link #1 = 100% (CLOSED), Link #2 = 0% (OPENED), Link #8 = Blink @ 0.5 sec |
| Receive Components (Channel #2) | Link #1 = 100% (CLOSED), Link #2 = 0% (OPENED), Link #8 = Blink @ 0.5 sec |
New for Generation 2, the OCM supports a maximum on-time setting — if you forget to shut the load off, the module will do it automatically. It can also be configured to notify the rest of the network when it automatically turns a load off, allowing it to remotely control other devices or update feedback indicators such as LEDs.
The OCM's internal switch relay is a path interrupter for devices not powered above 24VDC (5A) or 30VAC (3.3A).
The seller warrants this product, if used per all applicable instructions, to be free from original defects in materials and workmanship for five years from the date of purchase. See www.PulseWorx.com for exact warranty details.