  • Optex InSight HX-80N — Visual Verification PIR Camera Quick Start Guide

    September 08, 2026 4 min read

    Quick start installation guide for the Optex InSight HX-80N Visual Verification PIR camera.

    Full text manual (for reference)

    Quick installation guide for the OPTEX INS-HX-80N — an InSight Series Visual Verification PIR Camera. This "Quick Guide" covers the core installation steps for installers; the full installation instructions and camera manual are available online at OPTEX's navigation portal.

    Overview

    The InSight HX-80N combines a passive infrared (PIR) detector with an integrated camera for visual verification of alarm events, and is designed for registration with the CHeKT monitoring portal. Full manual: https://navi.optex.net/manual/50427

    Safety Symbols

    • Warning: Failure to follow these instructions and improper handling may cause death or serious injury.
    • Caution: Failure to follow these instructions and improper handling may cause injury and/or property damage.
    • Prohibition / Recommendation / Note icons mark specific do's, don'ts, and points needing special attention (e.g. do not mount on an unstable wall, do not disassemble/modify, avoid intentional watering).

    Parts & Accessories

    • Components: Camera unit, PIR detector, PIR cover, back cover, mounting plate, bracket angle adjusting screw, camera angle adjusting screw
    • Included accessories: 4x 20mm mounting screws (qty 2), T20 Torx wrench, waterproof cap for LAN connection

    Installation Steps

    1. Remove and install the mounting plate using the 2 provided screws. Hook the fall-prevention wire (caution item). To pass cables through the wall, drill a 25mm (1") or larger hole; use a single gang box for exposed wiring.
    2. Connect cables to the device via the 8-pin I/O cable (Pink, Orange, Yellow, Brown, Green, Purple, Black, Red wires) for Tamper Alarm and Power circuits (terminal labels: + − SP N/A COM AL TP TP). Do not connect to the N/A terminal. Also connect the DC power cable (12V DC for camera and PIR — can double as backup power for PoE) and the PoE LAN cable via the waterproof cap.
    3. Secure the main body back onto the mounting plate — take care not to pinch cables during assembly.

    IP Address Settings

    • Default network type is dynamic (DHCP). If no DHCP server is present, a static address is auto-assigned after one minute — check the label on the unit for the initial address.
    • Default username: root; Default password: OPTEX — change the password after initial setup.
    • Download the IP installer: https://navi.optex.net/firmware/50427

    CHeKT Portal Device Registration

    1. Go to dealer.chekt.com to log in (request a dealer account first if you don't have one, via www.chekt.com/registration).
    2. Select the customer, then the Site Devices tab.
    3. Select the bridge device to associate with the sensor camera, and access bridge settings via the gear icon.
    4. Select the appropriate tab to register the PIR camera.

    Camera Angle & PIR Area Settings

    • Horizontal adjustment: ±95°. Remove the back cover, loosen one side, and adjust — only one side needs to be loosened.
    • Vertical (PIR area) adjustment: 0° to -20°. Use only to make the detection area surface parallel to the ground's inclination — do not use for other purposes.
    • Camera angle adjustment: loosen the left or right screw; recommended range 25°–35° (default 30°) — images may appear white/blurred in dark scenes outside this range.
    • DIP switch settings: Switch 1 (Standard/Immunity), Switch 2 (Immunity, future use), Switch 3 (future use), Switch 4 (AND/OR PIR Logic).
    • PIR sensitivity: High (H), Middle (M, default), Low (L).

    Checking / Commissioning

    1. Walk test — check the detection area by walking around it.
    2. System check — verify the captured image at the time of detection via the monitoring portal.

    Specifications

    Detection method Passive infrared
    PIR coverage 24m x 2.0m (80' x 6'7") narrow, 20 zones
    PIR distance 6.5m (22'), 10m (33'), 13m (43'), Default: 18m (60'), 24m (80')
    Detectable speed 0.3 to 1.5 m/s (1' to 5'/s)
    Sensitivity 2.0°C (3.6°F) at 0.6 m/s
    Power input PoE (IEEE 802.3af); Mini-jack 12V DC 420mA max; Terminal 9.5-18V DC / 35mA max at 12V DC
    Alarm period 2.0 ± 1 s
    Warm-up period Approx. 60 s (LED blinks)
    Alarm output N.C./N.O. switchable, 28V DC 0.1A max
    Tamper output N.C. 28V DC 0.1A max, opens when cover is opened
    Image sensor 1/2.8" CMOS
    Viewing angle H: 114°, V: 61°
    Minimum illumination Color: 0.02 lux, 0 lux with IR
    IR illumination Visible up to 12m
    Night vision Day & Night automatic/manual switching
    Image compression H.264, H.265, MJPEG
    Resolution/frame rate 1080p / 30 fps, D1 (704x480 or 704x576)
    Network protocol IPv4: TCP/IP, UDP, RTP(UDP/TCP), RTSP, NTP, HTTP, HTTPS, SSL, DHCP, SNMPv1/v2/v3(MIB-2), ONVIF
    Security HTTPS(SSL), IP filtering, 802.1x, Digest authentication
    Operation temperature -30°C to +50°C (-22°F to +122°F)
    Environment humidity 95% max
    International protection IP 55
    Mounting Wall (Outdoor, Indoor) / Gang box
    Mounting height 2.5 to 3.0m (8'2" to 10'), default 2.5m (8.2 ft)
    Weight 1.2 kg (42.3 oz)

    Factory Reset

    To reset to factory default (e.g. if the password is forgotten): remove the back cover, locate the factory reset switch near the cable, and press for 5 seconds. This resets the IP address, ID, password, and camera settings.

    Compliance & Legal

    This product is equipped to produce moving images of the designated area but is not equipped to store or register such images. Prior to installation, compliance with local privacy/personal-information laws is the user's responsibility. FCC Class A digital device — designed for commercial environments; may cause interference in residential areas. Open source software components are distributed under GPL/LGPL and other OSS licenses; source code is available upon request for at least 3 years from purchase date.

    Manufacturer

    OPTEX CO., LTD. (Japan) — www.optex.net
    OPTEX INC. / Americas HQ (U.S.) — www.optexamerica.com
    OPTEX (Europe) Ltd. / EMEA HQ (U.K.) — www.optex-europe.com